• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Wednesday, November 18, 2026
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Health

Cool eyes on fever screening: Optimizing infrared thermography

Bioengineer by Bioengineer
September 14, 2020
in Health
Reading Time: 4 mins read
0
IMAGE
Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

Full-face readings can optimize fever screening with infrared thermographs

IMAGE

Credit: Image credit Q. Wang

Thermography has been a hot topic this year, due to the need for quicker diagnostics to detect and prevent the spread of COVID-19. Noncontact infrared thermometers (NCITs) are currently a primary tool for fever screening, but their widespread use has been prone to inaccuracy. A related medical technology, thermography using infrared thermographs (IRTs), enables increased options for temperature estimation with greater accuracy. Although the use of thermography as a stand-alone detection method for COVID-19 is unlikely to prevent spread, emerging evidence and international consensus suggest that it is indeed possible to use IRTs effectively for detecting elevated body temperatures.

A report published in the Journal of Biomedical Optics provides robust insights for optimizing IRT-based fever screening. The research, performed by Quanzeng Wang and collaborators at the Center for Devices and Radiological Health of the US Food and Drug Administration (FDA), evaluated the use of IRTs under standardized conditions. They examined clinical data for more than 500 demographically diverse individuals, including 47 subjects with elevated oral temperatures (>37.5 °C), correlating facial temperatures to oral under-the-tongue thermometer measurements. The team confirmed the utility of internationally recognized (ISO) standards for obtaining consistently accurate results, and specifically reported the efficacy of ISO methods, including facial area targets.

How do IRTs work?

We radiate heat as infrared energy, which changes as we get warmer. IRTs are camera systems that can sense infrared energy, allowing us to “see” the infrared waves. These readings display as a two-dimensional temperature distribution that correlates to temperature levels at the source. A human face typically shows varying temperatures, warmer where the larger arteries are closer to the surface of the skin such as the inner canthi (the eye corners where the tear ducts reside) and temples.

Optimizing IRTs

Like any technology, IRTs are subject to fundamental device and performance variations, which affect overall accuracy when used in medical practice. To minimize such variations, FDA researchers incorporated the ISO guidelines in their experiments (e.g., controlling ambient conditions, requiring individuals to acclimatize for 15 minutes prior to screening, etc.). They reported excellent IRT performance with clear correlations between IRT readings and oral temperature baseline data.

Aside from demonstrating the effectiveness of standardized methods for fever screening, some key insights emerged from the team’s analysis.

One of the most significant insights was that targeting the full face for temperature screening resulted in greater accuracy than narrowly targeting the inner canthi, as recommended by the ISO guidelines. This insight could be helpful in establishing future directions with these devices, as full-face imaging is much easier to implement since it does not require complex facial feature detection software to identify the inner canthi regions. The next-best performance included the extended inner canthi area that includes but is wider than the inner canthi regions recommended by the ISO guidelines. Targeting the narrow canthi regions produced third-best accuracy.

FDA researchers calculated a series of cutoff levels to optimize the sensitivity and specificity values of the IRT readings. Although there is no uniform consensus on what temperature constitutes a fever, an oral temperature in the range of 37.5°C to 38°C (99.5°F to 100.4°F) is most commonly used in the medical profession as the threshold. The authors caution that determining an appropriate cutoff temperature for real-world fever screening involves complex considerations, such as the likely rate of false positives or negatives, as well as such matters as delay times, staffing, asymptomatic illness, and related costs to health agencies.

IRT-based fever screening

If conducted according to standardized protocols to ensure accuracy, IRT-based fever screening may effectively identify individuals with elevated body temperatures including low-grade fevers (oral temperature?37.5°C) associated with early-stage infections and moderate symptoms. According to Zane Arp, Director of the Division of Biomedical Physics at the FDA, “IRT-based fever screening, especially in regard to addressing COVID-19, should be one element in a multilayered diagnostic process that would include other helpful tools. When used in combination with other diagnostics and medical screening it is a much more useful tool in detecting those who are ill.” For COVID-19 in particular, the FDA has published fact sheets on the proper use and limitations of these systems.

Given the potential value of IRTs for medical diagnostics, optimizing IRT-based fever screening is important, yet there remains much to learn. According to Wang, the FDA team plans further analysis to assess the potential impact of such factors as environmental and intersubject variability.

###

Read the original open access article: Y. Zhou, P. Ghassemi, et al., “Clinical evaluation of fever-screening thermography: impact of consensus guidelines and facial measurement location,” J. Biomedical Optics 25(9), 097002 (2020), doi 10.1117/1.JBO.25.9.097002.

Media Contact
Kevin Probasco
kevinp@spie.org

Original Source

https://spie.org/news/cool-eyes-on-fever-screening_optimizing-infrared-thermography

Related Journal Article

http://dx.doi.org/10.1117/1.JBO.25.9.097002

Tags: Critical Care/Emergency MedicineDiagnosticsHealth CareHealth Care Systems/ServicesHealth ProfessionalsInfectious/Emerging DiseasesMedicine/HealthPublic Health
Share12Tweet8Share2ShareShareShare2

Related Posts

Dynamic Physiological Measures Improve Long-Term Outcome Predictions in Traumatic Brain Injury

Dynamic Physiological Measures Improve Long-Term Outcome Predictions in Traumatic Brain Injury

November 18, 2026
IPMN-Linked Pancreatic Cancer Appears Uncommon in Patients Under Age 65

IPMN-Linked Pancreatic Cancer Appears Uncommon in Patients Under Age 65

November 18, 2026

Review Highlights Shift Toward Targeted Apoptosis in Injectable Fat Reduction

November 18, 2026

Virtual Planning and Patient-Specific Plates Achieve Mandibular Reconstruction in Feasibility Study

November 18, 2026
Please login to join discussion

POPULAR NEWS

  • Review Identifies Stage-Specific Biological Bottlenecks Limiting Long-Term Cancer Metastasis Control

    Review Identifies Stage-Specific Biological Bottlenecks Limiting Long-Term Cancer Metastasis Control

    29 shares
    Share 12 Tweet 7
  • Lightweight AI Models Enable Reliable Slip Detection on Microcontroller Hardware

    29 shares
    Share 12 Tweet 7
  • Overharvesting Threatens Traditional Cosmetic Plants in South Africa’s Eastern Cape

    29 shares
    Share 12 Tweet 7
  • Distributed Latent Encoding Cuts Cloud Media Retrieval Latency Across Six Datasets

    29 shares
    Share 12 Tweet 7

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

Dynamic Physiological Measures Improve Long-Term Outcome Predictions in Traumatic Brain Injury

Riparian Vegetation Connectivity and Forest Cover Shape Aquatic Insect Diversity Across Basins

Placental Stress Reprograms PSG1 Sugar Chains in Early-Onset Preeclampsia

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 88 other subscribers
  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.