• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Tuesday, November 24, 2026
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Technology

Simulations Reveal Structural Weaknesses in Historic Allahabad Masonry Clock Tower

by
November 24, 2026
in Technology
Reading Time: 6 mins read
0
Simulations Reveal Structural Weaknesses in Historic Allahabad Masonry Clock Tower

Simulations Reveal Structural Weaknesses in Historic Allahabad Masonry Clock Tower

Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

A comprehensive structural evaluation combining on-site visual surveys and three-dimensional finite element modeling has identified critical vulnerability zones across the historic 108-year-old unreinforced brick masonry clock tower at Allahabad University in India following the 2015 Nepal earthquakes. Although the 30.48-meter-tall monument exhibits adequate compressive capacity to endure vertical gravity loads, dynamic time history and static analyses reveal significant stress concentrations, plaster erosion, and severe cracking along its upper levels and structural connections. The investigation, published in the Asian Journal of Civil Engineering by researchers Ambareesh Kumar and Kumar Pallav, evaluated the five-storey Indo-Saracenic structure to understand its free vibration behavior, horizontal wind response, and resistance to synthetic seismic ground motions. While the robust construction of the ground and first floors demonstrated commendable resilience, the diminishing wall thickness and degraded binding materials on higher floors leave the historic structure susceptible to damage, highlighting an urgent need for targeted maintenance to ensure life safety and preserve architectural heritage.

Erected between 1910 and 1915 on the campus of Allahabad University—founded on September 23, 1887, as India’s fourth oldest university after Calcutta, Bombay, and Madras—the Senate Hall building represents a notable example of British engineering and Indo-Saracenic architecture conceived by Sir Swinton Jacob. The site selection for the Library, Senate House, and Law colleges occurred in 1909, with construction approved in 1910 and the foundation stone laid on January 17, 1910, by Chancellor Sir John Havett. Serving as a capacious institutional center for examinations, conferences, and convocations, the central hall alone accommodates more than 600 people surrounded by wide peripheral verandahs. Positioned prominently at the building’s eastern entrance gate, the clock tower stands as the second tallest masonry tower in Allahabad, rising from a rectangular foundation of blunted masonry bricks measuring 1.07 meters in height, with a base width of 9.60 meters and an adjacent side of 6.60 meters.

The architectural configuration of the tower incorporates symmetrical construction techniques, blending unreinforced brick masonry walls with structural and decorative stone elements across distinct floor levels. At the ground floor, external wall thickness measures 1.22 meters with an internal width of 1.0 meter, tapering gradually to 0.61 meters at the third floor. Internally, thick plaster fortifies the brick masonry surfaces, while the entire exterior is coated with a red paint finish. Expansive verandahs connect the ground and first floors, offering access to the building through generous arched openings. Above the first floor, decorative stone chips and stone elements adorn the junctions between walls and roofs. Movement within the tower relies on a spiral-shaped cantilever staircase anchored to the masonry walls. From the third floor upward to the dome access, wooden floors rest on nine-inch-thick sleepers aligned longitudinally. At the sixth-floor level, circular clocks are mounted on all four faces below a brick dome rising 3.35 meters.

Following the 2015 Nepal earthquakes, which produced significant seismic shaking that compounded damages from earlier events such as the 1934 Bihar-Nepal earthquake, engineers conducted an extensive visual inspection survey across the entire tower. While the ground floor retained a favorable structural state, severe physical deterioration was evident on upper levels, prompting authorities to restrict access beyond the second floor to protect public safety. Pronounced cracking manifested at the junctions between walls and roofs, on un-plastered surfaces, and along the interfaces connecting the spiral stairs to peripheral masonry walls. Furthermore, prolonged atmospheric exposure, moisture retention, and temperature fluctuations have severely deteriorated the binding lime mortar. Rainwater accumulation has triggered significant plaster erosion and brick spalling, while visible algae growth and minor vegetation have rooted along the damp interfaces between stone facades and brick walls. On the dome, the exterior white coloration has faded substantially to black alongside minor surface cracks.

To evaluate the tower’s performance under complex mechanical loading, the research team developed a detailed three-dimensional numerical model using ANSYS Workbench 14.0 based on on-site surveys and historical documentation. Adopting a macro-modelling and homogeneous continuum approach, the model represented major load-bearing components including walls, vaults, arches, columns, openings, and the dome, while omitting minor ornamental carvings to preserve computational efficiency. The structural block behavior was governed by the von-Mises failure criterion. The resulting finite-element mesh comprised 654,366 nodes and 385,465 higher-order SOLID187 elements, which are ten-noded tetrahedral solid elements featuring three translational degrees of freedom per node. A global element size of 100 millimeters with an edge length of approximately 32.92 millimeters was applied across the geometry, while localized mesh refinement was implemented at critical stress concentrations such as arched openings, stone columns, and masonry junctions to capture high stress gradients accurately under fully fixed base boundary conditions.

Because destructive material extraction from protected historical monuments is highly restricted, the authors determined mechanical parameters by retrospectively evaluating structural codes, architectural records, and non-destructive surveys of contemporaneous monumental structures erected between 1890 and 1920. The evaluation relied specifically on the anticipated mechanical characteristics of lime mortar, brick masonry, and stone elements that govern load transfer across the edifice. Mass density values were assigned in accordance with Indian Standard IS: 875 (Part-1), specifying 1600 to 1840 kilograms per cubic meter for lime mortar and 1920 kilograms per cubic meter for brick masonry. These calibrated mechanical attributes allowed the researchers to simulate static dead loads, horizontal wind pressures, and seismic vibrations through established linear elastic formulations. However, the authors explicitly noted that relying on approximated material values sourced from historical codes rather than direct core sampling represents a necessary methodological limitation, as the numerical model does not capture continuous cumulative deformation occurring over the tower’s 108-year lifespan.

The static gravity analysis, conducted under self-weight loading according to IS: 875 (Part-1) with restrained base nodes, revealed that the unreinforced masonry structure possesses adequate compressive capacity to support its own mass. Under pure dead weight, the numerical model calculated a maximum downward deformation of 3.76 millimeters at the dome apex, while equivalent von-Mises stresses reached a peak of 1.81 megapascals at the connection joint of the first-floor level. Because compressive stresses induced by combined self-weight and live loads remained well below the allowable compressive limits in IS: 1905-1987, the primary load-bearing walls demonstrated structural safety against vertical collapse. To simulate lateral environmental forces, an equivalent static horizontal wind analysis was performed following IS: 875 (Part-3), applying wind pressures from the southwest direction above the sheltered 6.09-meter base level. The lateral wind load induced a top displacement of 5.17 millimeters at the dome, generating a maximum compressive stress of 1.51 megapascals concentrated at the downwind base.

To characterize the fundamental dynamic properties of the monument, the investigators carried out three-dimensional modal analysis under boundary conditions identical to the gravity assessment using the Block Lanczos Method. The numerical calculation evaluated both free vibration and wind-induced forced vibration across the structure, extracting natural frequencies, mode shapes, and effective mass participation factors. For free vibration, the first three modal frequencies were determined to be 1.732 hertz, 2.147 hertz, and 3.922 hertz, respectively, while forced vibration analysis under east-directed wind pressure above 10 meters yielded nearly identical modal responses. The mass participation factor reached approximately 55 percent of the total structural mass across the first two vibrational modes in both the longitudinal X and transverse Z directions. This symmetrical mass distribution and comparable dynamic behavior between orthogonal axes reflect the tower’s geometric symmetry along its longitudinal vertical axis, demonstrating that the lower stories provide a balanced structural core despite architectural connections to adjacent buildings.

Dynamic time history analysis was subsequently executed to evaluate the tower’s seismic vulnerability in compliance with the revised Indian standard IS: 1893-2016. Because instrumental strong ground motion records were unavailable for the city of Allahabad, the authors synthesized a site-specific acceleration time history using Boore’s stochastic method and the source spectrum formulation outlined by Motazedian and Atkinson. Incorporating a reference stress drop of 100 bars within the regional Indo-Gangetic Plain range of 50 to 200 bars described by Kayal, the synthetic motion simulated an earthquake scenario from the local Allahabad fault exhibiting a peak ground acceleration of 1.29 meters per second squared with five percent damping. Applied longitudinally at the tower’s fixed foundation, the seismic excitation produced de-amplified acceleration responses along the height, registering 1.95 times 10 to the negative fourth meters per second squared at the first floor and 1.98 times 10 to the negative third meters per second squared at the dome, while maximum apex displacement reached 0.0035 millimeters.

Although dynamic displacements and global stresses under the simulated ground motion remained relatively low—with localized stress concentrations reaching 2.47 times 10 to the negative fourth megapascals on the first floor and 3.86 times 10 to the negative fourth megapascals on the second floor—the locations of maximum numerical stress coincided precisely with the severe cracks mapped during visual surveys. The analytical results confirm that un-plastered masonry surfaces, wall-to-roof joints, and the junction between the clock tower and the main Senate Hall facade endure substantial stress demands during lateral shaking. The authors concluded that while the thick, well-crafted masonry of the lower stories offers admirable structural resistance, the progressive decline in wall thickness and the widespread decay of binding mortar on upper levels pose serious preservation risks. Preventing catastrophic damage during future earthquakes will require systematic engineering interventions, including the renewal of moisture-damaged lime mortar, structural strengthening of stair and wall connections, and the judicious incorporation of modern retrofitting techniques designed to preserve the monument’s historical integrity.

Subject of Research: Finite element seismic and structural analysis of a historic unreinforced brick masonry tower

Article Title: Finite element analysis of a 108-year-old unreinforced brick masonry tower following the 2015 Nepal earthquakes

Article References: Kumar, A., & Pallav, K. (2024). Finite element analysis of a 108-year-old unreinforced brick masonry tower following the 2015 Nepal earthquakes. Asian Journal of Civil Engineering, 25(2), 2175-2188. https://doi.org/10.1007/s42107-023-00902-z

Image Credits: AI Generated

DOI: 10.1007/s42107-023-00902-z

Keywords: unreinforced brick masonry, finite element analysis, Senate Hall clock tower, Allahabad University, 2015 Nepal earthquakes, ANSYS Workbench, dynamic time history analysis, modal analysis, von-Mises stress, peak ground acceleration, Block Lanczos Method, stochastic ground motion, structural health monitoring, historic monument preservation, SOLID187 elements, equivalent static wind analysis, Indo-Saracenic architecture

News Source: Denise Maddox. (November 24, 2026). Simulations Reveal Structural Weaknesses in Historic Allahabad Masonry Clock Tower. Scienmag.

Tags: 2015 Nepal earthquakesAllahabad UniversityANSYS WorkbenchBlock Lanczos Methoddynamic time history analysisequivalent static wind analysisfinite element analysishistoric monument preservationIndo-Saracenic architecturemodal analysispeak ground accelerationSenate Hall clock towerSOLID187 elementsstochastic ground motionStructural Health Monitoringunreinforced brick masonryvon Mises stress
Share12Tweet7Share2ShareShareShare1

Related Posts

Machine Learning Models Enhance Combustion Modeling and Stability Monitoring in Gas Turbines

Machine Learning Models Enhance Combustion Modeling and Stability Monitoring in Gas Turbines

November 24, 2026
Local Open-Weight Language Models Standardize Emergency EEG Narratives Into Structured Clinical Descriptors

Local Open-Weight Language Models Standardize Emergency EEG Narratives Into Structured Clinical Descriptors

November 24, 2026

Wearable Markerless Augmented Reality System Tracks Temporal Bone Phantoms Within Millimeters

November 24, 2026

Fuzzy Multi-Task Matrix Machine Improves Diagnostic Accuracy Across Bearings and Gears

November 24, 2026

POPULAR NEWS

  • Scenario Models Link Fine Particulate Pollution to Substantial Mental Health Burdens

    Scenario Models Link Fine Particulate Pollution to Substantial Mental Health Burdens

    29 shares
    Share 12 Tweet 7
  • Review Maps Bacterial Cellulose Nanocomposites for Next-Generation Lithium Energy Storage

    29 shares
    Share 12 Tweet 7
  • Machine Learning Models Enhance Combustion Modeling and Stability Monitoring in Gas Turbines

    29 shares
    Share 12 Tweet 7
  • Himalayan Fieldwork Documents Ethnoecological Knowledge and Medicinal Uses of Thirty-One Birds

    29 shares
    Share 12 Tweet 7

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

Standardized Metagenomic Workflows Uncover Functional Potential in Complex Soil Microbiomes

Narrative Review Details Bowel Endometriosis Manifestations, Diagnostic Approaches, and Multidisciplinary Care

Duck Tail Wagging May Signal Welfare Changes in Commercial Flocks

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 89 other subscribers
  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.