• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Wednesday, November 25, 2026
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Health

Pacemaker Placement in Pediatric Heart Block Shows Early Ejection Fraction Gains

by
November 25, 2026
in Health
Reading Time: 3 mins read
0
Pacemaker Placement in Pediatric Heart Block Shows Early Ejection Fraction Gains

Pacemaker Placement in Pediatric Heart Block Shows Early Ejection Fraction Gains

Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

Permanent pacemaker implantation in pediatric patients with complete heart block is associated with early improvements in left ventricular ejection fraction alongside complex shifts in tissue doppler echocardiographic measurements. In an observational cohort investigation, researchers evaluated cardiac performance before and after device interventions to determine how standard mechanical function and regional myocardial velocities respond in young patients requiring pacing therapy.

Pediatric complete heart block can emerge congenitally or develop as a post-operative complication of cardiac surgery in individuals treated for congenital heart disease. Clinically, this conduction abnormality manifests through age-inappropriate bradycardia, diminished cardiac output, or clinical symptoms indicative of congestive heart failure. Because these hemodynamic disturbances pose substantial physiological burdens, the majority of affected pediatric cases require permanent pacemaker implantation before reaching young adulthood to restore rate and output.

To clarify these post-implantation functional changes, the clinical investigation enrolled an observational cohort comprising 35 pediatric patients diagnosed with complete heart block. Prior to surgical device placement, each participant underwent comprehensive baseline assessments using conventional two-dimensional echocardiograms combined with tissue doppler imaging protocols. These initial clinical evaluations established essential baseline parameters across ventricular chambers before the introduction of therapeutic artificial electrical pacing.

Following pacemaker placement, the clinical team executed follow-up imaging protocols at defined post-procedure intervals structured specifically by the pacing approach used. The second tissue doppler imaging evaluation took place 48 hours after the insertion of endocardial pacing leads, whereas patients managed with epicardial pacing underwent assessment 10 days post-procedure. This scheduled approach allowed the investigators to record early postoperative echocardiographic adaptations across both patient pacing groups.

The primary functional evaluation revealed that patient ejection fraction increased significantly from a baseline mean of 43.1 ± 4.7 percent to 49.9 ± 5.6 percent after pacemaker implantation, demonstrating a statistically significant improvement with a p-value below 0.001. Despite this overall gain in systolic pump performance, several specific tissue doppler indices showed no significant change. Unaltered measurements included left ventricular a′ velocity evaluated via pulsed-wave tissue doppler, left ventricular e′/a′ ratios obtained through two-dimensional color-coded tissue doppler, right ventricular deceleration time, right ventricular a′ velocity, and right ventricular isovolumetric relaxation time.

The researchers also examined whether echocardiographic responses diverged between patients presenting with congenital complete heart block and those who developed the condition following cardiac surgical procedures. Initial between-group comparisons identified statistically significant differences in right ventricular e′ velocities and left ventricular E/e′ ratios after device placement. However, neither difference remained statistically significant after adjustment for multiple comparisons, and no significant variations were detected across the other measured echocardiographic parameters.

Overall, permanent pacing produced early improvements in left ventricular ejection fraction alongside significant decreases in tissue doppler-derived S′ and e′ velocities for both ventricles, as well as decreases in several conventional diastolic indices. The study authors emphasized that this mixed and inconsistent hemodynamic pattern requires cautious interpretation rather than being viewed as isolated evidence of ventricular dysfunction. Furthermore, the investigators noted that these favorable short-term functional observations cannot exclude the possibility of late ventricular dysfunction associated with chronic ventricular pacing, particularly right ventricular apical pacing.

Subject of Research: Echocardiographic and tissue Doppler changes following pacemaker implantation in pediatric complete heart block

Article Title: Evaluation of tissue doppler echocardiography in pediatric patients with complete heart block after pacemaker implantation

Article References: Khorgami, M. R., Masihi, R., Sadeghi, D., Hejri, G. M., Rashidi Ghader, F., Moradian, M., & Abdolkarimi, L. (2026). Evaluation of tissue doppler echocardiography in pediatric patients with complete heart block after pacemaker implantation. BMC Cardiovascular Disorders. https://doi.org/10.1186/s12872-026-07065-0

Image Credits: AI Generated

DOI: 10.1186/s12872-026-07065-0

Keywords: pediatric complete heart block, permanent pacemaker implantation, tissue doppler imaging, ejection fraction, congenital heart block, post-surgical heart block, endocardial pacing, epicardial pacing, two-dimensional echocardiography, pulsed-wave tissue doppler, color-coded tissue doppler, bradycardia, cardiac output, congestive heart failure, ventricular dysfunction, right ventricular apical pacing

News Source: Harold Sullivan. (November 25, 2026). Pacemaker Placement in Pediatric Heart Block Shows Early Ejection Fraction Gains. Scienmag.

Tags: bradycardiacardiac outputcolor-coded tissue dopplercongenital heart blockcongestive heart failureejection fractionendocardial pacingepicardial pacingpediatric complete heart blockPermanent Pacemaker Implantationpost-surgical heart blockpulsed-wave tissue dopplerright ventricular apical pacingtissue Doppler imagingtwo-dimensional echocardiographyventricular dysfunction
Share12Tweet7Share2ShareShareShare1

Related Posts

Clinical Oversight Remains Essential as Artificial Intelligence Expands Across Global Travel Medicine

Clinical Oversight Remains Essential as Artificial Intelligence Expands Across Global Travel Medicine

November 25, 2026
Allergic Rhinitis Associates With Small Airway Dysfunction in Severe Asthma Patients

Allergic Rhinitis Associates With Small Airway Dysfunction in Severe Asthma Patients

November 25, 2026

Resuscitation artificial intelligence risks reproducing documented sex disparities in emergency care

November 25, 2026

CT Radiomics Model Estimates Small Bowel Obstruction Surgical Risk in Multicenter Study

November 25, 2026

POPULAR NEWS

  • Machine Learning Powers Electronic Noses for Food Freshness and Authenticity Assessment

    Machine Learning Powers Electronic Noses for Food Freshness and Authenticity Assessment

    29 shares
    Share 12 Tweet 7
  • Review Highlights Multimodal Diagnostic Strategies Amid Global Resurgence of Neurosyphilis

    29 shares
    Share 12 Tweet 7
  • Gallic Acid Metal Assemblies Deliver Tunable Nanoscale Redox Functions for Disease Therapies

    29 shares
    Share 12 Tweet 7
  • Clinical Trial Protocol Evaluates Yangxinshi Tablets for Incomplete Coronary Revascularization Chest Pain

    29 shares
    Share 12 Tweet 7

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

Clinical Oversight Remains Essential as Artificial Intelligence Expands Across Global Travel Medicine

Alligatorweed Competition Cuts Mungbean Yields by Up to 52 Percent

Survey Reveals Broad Variation in Academic Vulvar Cancer Surgical Staging Practices

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 89 other subscribers
  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.