• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Thursday, October 2, 2025
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Health

New polysomnography electrode set enables easy at-home assessment of sleep bruxism

Bioengineer by Bioengineer
October 18, 2019
in Health
Reading Time: 3 mins read
0
IMAGE
Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

IMAGE

Credit: Tomi Miettinen


An easy-to-use electrode set can assess sleep bruxism severity as well as a conventional polysomnography, a new study from the University of Eastern Finland shows.

Sleep bruxism, commonly known as clenching or grinding of the teeth during sleep, affects approximately 8-15% of the population. Sleep bruxism can lead to various negative health consequences, such as tooth wear, facial pain and headaches. Sometimes, teeth grinding can be so loud that it disturbs the sleep of others in the same room.

Currently, the treatment of sleep bruxism is mainly focused on managing its consequences. One reason behind our lack of understanding of sleep bruxism and its treatment is the fact there is no single severity assessment method that would at the same time be reliable, accurate, cost-effective and easily available. Accurate assessment of sleep bruxism severity requires bioelectric measurements, of which sleep laboratory polysomnography is the most accurate one. Unfortunately, it has limited availability and is considered expensive, which is why it is prioritised for the diagnosis of the most severe sleep disorders only.

Some user-friendly devices for sleep bruxism assessment that measure masticatory muscle activity have been introduced to the markets, allowing patients to use them in the comfort of their own home. However, these devices often fall short in accuracy, failing to differentiate between sleep bruxism and other masticatory muscle activity, such as yawning and swallowing.

Previously, researchers at the University of Eastern Finland and Kuopio University Hospital in Finland have developed a screen-printed emergency EEG electrode set, which has been shown to be quick and easy to use and to have high signal quality in clinical settings. In addition, the electrode set can be used for sleep stage determination during sleep laboratory polysomnography.

Now, the technology used in the emergency EEG set was further developed as part of a doctoral thesis project in order to provide a highly accurate method for polysomnographic sleep bruxism assessment in research and clinical settings in patients’ own homes. The diagnostic accuracy of the electrode set was compared to the diagnostic accuracy of a conventional polysomnography and other bioelectric measurements.

“The upgraded version of the electrode set is extremely well-suited for accurate assessment of sleep bruxism severity. In fact, its diagnostic accuracy is similar to that of a conventional polysomnography, when using the same methods for differentiating sleep bruxism related activity from other nocturnal events,” PhD Student Tomi Miettinen, MSc, from the University of Eastern Finland says.

According to the study, the electrode set is reliable and easy enough to be used by patients in their own home. Nine out of ten at-home polysomnography recordings were of good quality, and the electrical impedance of the electrodes was at an acceptable level 90% of the time. Only one out of 101 recordings failed due to problems related to the electrode set. Supporting evidence was also found for a previous finding that some patients may present altered results on the first night due to the so-called first night effect, and sleep bruxism assessment may require more than one night of recording.

“The electrode set is especially well suited for recordings that are more demanding in assessing sleep bruxism activity accurately over the duration several nights. The electrode set could be considered especially applicable for solving different research questions related to sleep bruxism, such as unclear connections between sleep bruxism activity and its presumed consequences and co-morbidities, as well as long-term efficacy of the management methods. As a tool, the electrode set has potential to increase our understanding of sleep bruxism, possibly resulting in more efficient methods to manage, or even treat sleep bruxism.” Miettinen concludes.

###

The findings were presented by Tomi Miettinen, MSc, in his doctoral dissertation entitled Suitability of a Self-applicable Electrode Set for Polysomnographic Assessment of Sleep Bruxism in the Home Environment, which is available for download at: http://epublications.uef.fi/pub/urn_isbn_978-952-61-3184-9/urn_isbn_978-952-61-3184-9.pdf

For further information, please contact:

PhD Student Tomi Miettinen, MSc, [email protected]

Original article:

Miettinen, T., Myllymaa, K., Muraja-Murro, A. et al. Sleep Breath (2019). https://doi.org/10.1007/s11325-019-01915-2

Media Contact
Tomi Miettinen
[email protected]

Related Journal Article

http://dx.doi.org/10.1007/s11325-019-01915-2

Tags: Dentistry/Periodontal DiseaseMedicine/Health
Share12Tweet8Share2ShareShareShare2

Related Posts

Mount Sinai Study Reveals How Sex-Based Pelvic Differences Impact Spinal Screw and Rod Placement in Surgery

October 2, 2025

Prolonged U.S. Residency Linked to Rising Heart Disease Risk Among Immigrants

October 2, 2025

Tracking Vitamin D Level Changes Amid COVID-19 Pandemic

October 2, 2025

Multimedia Measurements Reveal PFAS Exposure at Home

October 2, 2025
Please login to join discussion

POPULAR NEWS

  • New Study Reveals the Science Behind Exercise and Weight Loss

    New Study Reveals the Science Behind Exercise and Weight Loss

    91 shares
    Share 36 Tweet 23
  • New Study Indicates Children’s Risk of Long COVID Could Double Following a Second Infection – The Lancet Infectious Diseases

    78 shares
    Share 31 Tweet 20
  • Physicists Develop Visible Time Crystal for the First Time

    74 shares
    Share 30 Tweet 19
  • How Donor Human Milk Storage Impacts Gut Health in Preemies

    64 shares
    Share 26 Tweet 16

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

Mount Sinai Study Reveals How Sex-Based Pelvic Differences Impact Spinal Screw and Rod Placement in Surgery

Prolonged U.S. Residency Linked to Rising Heart Disease Risk Among Immigrants

Virtual Reality: A Promising Tool for Alleviating Anxiety in Patients Facing Interventional Cardiovascular Procedures

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 60 other subscribers
  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.