• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Saturday, December 20, 2025
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Chemistry

Detecting small amounts of virus in early infections

Bioengineer by Bioengineer
September 1, 2020
in Chemistry
Reading Time: 3 mins read
0
IMAGE
Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

Device could preconcentrate samples from COVID-19 patients in asymptomatic stages of the disease, providing early detection capability

IMAGE

Credit: Amy Drexelius

WASHINGTON, September 1, 2020 — Diagnostic devices that are used at home or in doctors’ offices are often not sensitive enough to detect small amounts of a virus that might be present in samples from asymptomatic patients, which can occur in early stage COVID-19. In Biomicrofluidics, by AIP Publishing, scientists report a membrane-based invention that can concentrate the virus content of a sample of urine or saliva, allowing it to be detected.

To increase sample concentration, previous groups have used gel particles, coupled to a chemical dye, to trap and detect a virus, but this approach is restricted to specific viruses that can bind to the dye. In addition, the testing time can be more than 30 minutes and requires expensive equipment.

Other approaches have been tried, but all lack the ability to diagnose different viruses or other biosubstances of interest, such as human chorionic gonadotropin, a hormone present in the urine during pregnancy.

Researchers at the University of Cincinnati and Wright-Patterson Air Force Base tried two different devices, both based on similar membrane-filter systems.

The first device was a fully integrated concentration unit coupled with a component that could detect the virus in question. A vacuum was used to pull water through the membrane, leaving behind the virus in a more concentrated solution, and the sample was analyzed in the same device.

“The amount of time needed to complete the concentration process was very slow,” said author Amy Drexelius. “On average, each device took about 30 minutes to complete the concentration process. We, therefore, concluded that the vacuum driven auto-staging device is not practically useful and turned to an alternate device utilizing a much higher positive pressure.”

The second device was considered because the investigators realized that by applying high pressure, instead of high vacuum, they could increase the pressure differential between the sample and the surroundings. A nitrogen gas tank and regulator were attached to their second device, allowing the application of up to 100 pounds per square inch of pressure.

The group investigated real biofluids, saliva and urine, spiked with samples of protein from influenza A virus. Other samples contained HCG.

“The test results were extremely consistent with the second device, showing a concentration result of 33 times that of the original sample,” said Drexelius. “Preconcentration of a 1-milliliter sample could be achieved in five minutes or even faster with higher applied pressures.”

The novel coronavirus that causes COVID-19 was not tested, but the method should work for it, since the technology could successfully detect influenza A. Both are respiratory viruses likely to be present in saliva. The technique is, in addition, promising for pregnancy testing, where early results are also highly desirable.

###

The article, “Analysis of pressure-driven membrane preconcentration for point-of-care assays,” is authored by Amy Drexelius, Anna Hoellrich, Andrew Jajack, Eliot Gomez, Michael Brothers, Saber Hussain, Steve S. Kim, and Jason Heikenfeld. The article will appear in Biomicrofluidics on Sept. 1, 2020 (DOI: 10.1063/5.0013987). After that date, it can be accessed at https://aip.scitation.org/doi/10.1063/5.0013987.

ABOUT THE JOURNAL

Biomicrofluidics rapidly disseminates research in fundamental physicochemical mechanisms associated with microfluidic and nanofluidic phenomena. The journal also publishes research in unique microfluidic and nanofluidic techniques for diagnostic, medical, biological, pharmaceutical, environmental, and chemical applications. See https://aip.scitation.org/journal/bmf.

Media Contact
Larry Frum
[email protected]

Related Journal Article

http://dx.doi.org/10.1063/5.0013987

Tags: BiologyBiomechanics/BiophysicsChemistry/Physics/Materials SciencesDiagnosticsEpidemiologyInfectious/Emerging DiseasesMedicine/HealthVirology
Share12Tweet8Share2ShareShareShare2

Related Posts

Cutting Electrolyte Reduction Boosts High-Energy Battery Performance

Cutting Electrolyte Reduction Boosts High-Energy Battery Performance

December 19, 2025
Microenvironment Shapes Gold-Catalysed CO2 Electroreduction

Microenvironment Shapes Gold-Catalysed CO2 Electroreduction

December 11, 2025

Photoswitchable Olefins Enable Controlled Polymerization

December 11, 2025

Cation Hydration Entropy Controls Chloride Ion Diffusion

December 10, 2025
Please login to join discussion

POPULAR NEWS

  • Nurses’ Views on Online Learning: Effects on Performance

    Nurses’ Views on Online Learning: Effects on Performance

    70 shares
    Share 28 Tweet 18
  • NSF funds machine-learning research at UNO and UNL to study energy requirements of walking in older adults

    71 shares
    Share 28 Tweet 18
  • Unraveling Levofloxacin’s Impact on Brain Function

    53 shares
    Share 21 Tweet 13
  • Exploring Audiology Accessibility in Johannesburg, South Africa

    51 shares
    Share 20 Tweet 13

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

Why Multiregional Accounting Matters for Corporate Emissions

Predicting Hospitalization Disability in Older Heart Failure Patients

Patient Tech Readiness and Nursing Robot Adoption

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 70 other subscribers
  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.