Visual evaluation of capillary refill time by intensive care clinicians demonstrated only moderate measurement reproducibility and failed to capture graded peripheral perfusion changes in a controlled experimental study, whereas near-infrared spectroscopy and an automated colorimetric video algorithm successfully detected the hemodynamic alterations. Capillary refill time has served for decades as a conventional physical examination maneuver at the bedside, and its standing within critical care medicine expanded after recent randomized clinical trials incorporated the metric directly into therapeutic resuscitation protocols for circulatory shock. Despite widespread adoption, the precision of subjective visual inspection under standardized conditions has remained uncertain, and objective monitoring instruments designed to eliminate observer-dependent variation are not widely implemented in daily practice. To address these physiological and diagnostic questions, researchers evaluated whether clinicians relying on unaided visual timing could detect subtle microcirculatory impairments induced by controlled arm congestion, comparing their findings against quantitative colorimetric software and continuous tissue oxygenation recordings.
The physiological premise of capillary refill testing rests on measuring the interval required for cutaneous microvascular blood flow to return following brief local tissue compression. When peripheral perfusion is compromised by shock or elevated venous pressures, microvascular transit slows, lengthening the time needed for blanched skin to regain its baseline reddish hue. However, the reliability of this clinical sign is frequently complicated by intrinsic biological factors and external physical variables, including endothelial function, neurovascular tone, local cutaneous temperature, and the specific magnitude of mechanical force applied during compression. Furthermore, human visual perception and manual stopwatch operation inevitably introduce substantial interobserver and intraobserver discrepancies. While earlier investigations in healthy cohorts attempted to establish normative thresholds and reproducibility indices, their findings proved inconsistent, frequently because earlier research relied on small panels of observers or averaged multiple consecutive readings, a labor-intensive approach that proves exceedingly difficult to replicate in high-pressure emergency and intensive care environments.
To evaluate these measurement properties rigorously, investigators formulated a cross-sectional comparative observational trial using a standardized healthy-volunteer model of fingertip-pulp compression paired with graded venous congestion. The research cohort comprised eight healthy adult Latin American volunteers, including four men and four women with light skin pigmentation, exhibiting a median age of 28.5 years and an overall age range between 26 and 36 years. Eligibility criteria strictly required the absence of any chronic pharmaceutical therapies and clinically meaningful medical history, with an age restriction spanning 18 to 45 years. All study participants were recruited from hospital intensive care staff and provided written informed consent under an institutional ethics committee approval. By conducting the experimental protocol within a homogeneous and healthy cohort, the research team sought to isolate pure microcirculatory dynamics and eliminate the confounding systemic variables that typically accompany clinical sepsis and complex multiorgan failure.
The experimental procedures were conducted across three consecutive days in 2023 inside a dedicated indoor examination room maintained under stable ambient parameters. Environmental conditions included an approximate ambient room temperature of 23 degrees Celsius and invariant artificial lighting calibrated to a color temperature of 5600 Kelvin to prevent lighting shifts from altering cutaneous color perception. Each volunteer underwent three sequential hemodynamic states starting with baseline physiological measurements obtained in the complete absence of venous congestion. Blood pressure was quantified once, followed by a one-minute pause before a standard pneumatic cuff positioned around the ipsilateral arm was inflated to 50 percent of the volunteer’s measured diastolic blood pressure. This initial stage of controlled venous congestion was maintained for 240 seconds. Following a two-minute deflationary recovery interval, an identical compression sequence was repeated with the arm cuff pressurized to 75 percent of the individual’s diastolic blood pressure.
Standardized visual records of microvascular refilling were acquired using a Sony a6400 digital camera fitted with a 16 to 50 millimeter kit lens mounted at a fixed distance of 20 centimeters directly above the subject’s hand. This positioning ensured stable focal distance while preventing shadowing across the test surface. Standardized microvascular compression was executed against the index fingertip pulp using a rigid glass slide pressed firmly for exactly 10 seconds before instantaneous release, adhering strictly to the operational maneuver validated in the ANDROMEDA trials. Digital video captures occurred at predefined intervals of 20, 40, 60, 80, and 240 seconds during each congestion phase. Every video segment was stripped of identifying markers and assigned a randomly generated alphanumeric code to ensure that subject identity and experimental congestion status remained entirely concealed from subsequent evaluation panels.
Sixteen intensive care unit clinicians, comprising attending physicians and medical residents working within the same clinical department, independently assessed the coded video recordings in randomized sequences. Each physician reviewed 150 unique video presentations, which incorporated blind duplicated stimuli to evaluate individual consistency, with one clinician assessing 151 segments, resulting in a dataset of 2401 visual evaluations. Raters remained completely masked to the volunteer’s identity and physiological condition, using manual stopwatches to record elapsed time in seconds from the release of glass-slide compression until complete recovery of normal cutaneous coloration. Concurrently, regional tissue oxygen saturation was monitored continuously at three-second intervals using a Medtronic INVOS Series 5100 C near-infrared spectroscopy device. The spectroscopy sensor was adhered across the thenar eminence of the ipsilateral hand, providing 904 discrete physiological observations across the study duration.
To establish an objective colorimetric comparator, the researchers developed custom Python software specifically tailored for automated chromatic processing of fingertip reperfusion. The software tracked a defined region of interest across the index fingertip pulp, isolated red-channel color intensity, and converted the post-ischemic reperfusion sequence into a continuous numerical time series. Rather than relying on human judgment, the algorithm fitted the recovery curve with an exponential decay model using a least-squares mathematical approach. Whereas earlier experimental frameworks utilized a 90 percent signal recovery threshold, this automated pipeline defined capillary refill duration as the exact time required to reach 95 percent of complete color recovery. Out of 88 recorded video files submitted for algorithmic processing, 53 recordings were successfully evaluated, representing an analytical completion rate of 60.2 percent, while 35 videos were excluded due to finger displacement from the tracking frame.
Statistical evaluation of the 2401 manual clinician timings demonstrated an overall mean visually assessed capillary refill duration of 1.77 seconds with a standard deviation of 0.65 seconds. A linear mixed-effects model incorporating crossed random effects for subject, operator, and video recording revealed that visual assessments did not detect statistically significant differences across venous congestion levels, yielding an F-ratio of 1.45 and a p-value of 0.23. Similarly, duration of cuff inflation produced no significant effect, exhibiting an F-ratio of 1.48 and a p-value of 0.230. The fitted model accounted for minimal variance attributable to experimental variables, demonstrating a marginal coefficient of determination of 0.04 and a conditional coefficient of determination of 0.44. Interobserver agreement reached an intraclass correlation coefficient of 0.52 with a 95 percent bootstrap confidence interval spanning 0.42 to 0.61, accompanied by a coefficient of repeatability of 1.20 seconds, while mean intraobserver reliability registered at 0.69.
A mathematical simulation based on residual-error variance demonstrated that visual reliability improved substantially when evaluations from multiple independent medical observers were mathematically combined. As the simulated rater pool expanded, the intraclass correlation coefficient progressed from 0.52 for a single clinician to 0.76 when averaging three observers, reaching 0.84 with five raters and 0.92 when pooling ten evaluations. Residual model error declined in direct proportion to observer group size, indicating that aggregating multiple subjective readings can suppress random measurement noise. However, the study authors emphasized that stationing three to five independent intensive care physicians to conduct parallel timed assessments over a single patient’s fingertip is entirely unfeasible during emergency resuscitation, underscoring that unaided visual inspection conducted by a solitary healthcare provider remains intrinsically imprecise and prone to diagnostic misclassification when serial changes remain subtle.
In marked contrast to visual assessment, objective monitoring modalities clearly identified the physiological disturbances induced by the pneumatic cuff. Near-infrared spectroscopy demonstrated statistically significant alterations linked to both experimental condition and time elapsed under congestion, achieving a p-value below 0.001 and a conditional coefficient of determination of 0.89. Tissue oxygenation declined progressively throughout the maneuvers, producing an 8.46 percent divergence in late-phase tissue saturation between 50 percent and 75 percent diastolic blood pressure states, alongside significantly suppressed nadir saturation values under heavier venous congestion. Similarly, automated Python video analysis across the 53 validated video files yielded a mean refill duration of 3.89 seconds with a standard deviation of 1.26 seconds. The automated software detected a statistically significant congestion effect, exhibiting an F-ratio of 6.32, a p-value of 0.016, a marginal coefficient of determination of 0.12, and a conditional coefficient of determination of 0.48, identifying an average prolongation of 0.68 seconds under higher congestion levels.
The study authors highlighted several methodological limitations that temper immediate clinical translation, noting that young healthy volunteers under localized venous congestion do not capture the profound metabolic disruption and systemic inflammation seen in circulatory shock. Additionally, while the custom Python software proved sensitive to subtle microcirculatory shifts, the tool was developed under supervised experimental conditions without independent multicenter validation, external benchmarking, or an established normative cohort. Furthermore, algorithmic analysis was vulnerable to minute physical motion, necessitating the exclusion of nearly 40 percent of video recordings due to region-of-interest displacement. Ambient temperature, while stable near 23 degrees Celsius, was not regulated by an active environmental control system, and the spectroscopy probe sampled thenar tissue rather than the index pulp. Consequently, while visual capillary refill time retains broad bedside utility as a rapid qualitative check, these findings demonstrate that solitary visual readings should not guide critical hemodynamic decisions, supporting the future refinement of automated digital monitoring systems.
Subject of Research: Reproducibility and physiological sensitivity of visual capillary refill time assessment compared with automated colorimetry and near-infrared spectroscopy
Article Title: Reproducibility and variability of visual capillary refill time assessment by intensive care physicians: comparison with near-infrared spectroscopy and automated video analysis in a cross-sectional observational study
Article References: Goette, N. A., Gutierrez, F. J., Mazza, J. I., Pozo, M. O., & Murias, G. E. (2026). Reproducibility and variability of visual capillary refill time assessment by intensive care physicians: comparison with near-infrared spectroscopy and automated video analysis in a cross-sectional observational study. Intensive Care Medicine Experimental, 14(1), Article 146. https://doi.org/10.1186/s40635-026-01001-4
Image Credits: AI Generated
DOI: 10.1186/s40635-026-01001-4
Keywords: Capillary Refill Time, Intensive Care Medicine, Venous Congestion, Near-Infrared Spectroscopy, Tissue Oxygen Saturation, Colorimetric Video Analysis, Interobserver Variability, Intraobserver Reproducibility, Intraclass Correlation Coefficient, Coefficient of Repeatability, Linear Mixed-Effects Models, Hemodynamic Resuscitation, Peripheral Perfusion, Bedside Monitoring, Microcirculation, Clinical Precision, Python Software Analysis
News Source: Ophelia Keating. (November 25, 2026). Visual Capillary Refill Time Fails to Detect Graded Venous Congestion Changes. Scienmag.