• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Monday, November 16, 2026
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Health

Tibial Torsion Increases After Osteotomy Only Without Hinge Fracture

by
November 12, 2026
in Health
Reading Time: 3 mins read
0
Tibial Torsion Increases After Osteotomy Only Without Hinge Fracture

Tibial Torsion Increases After Osteotomy Only Without Hinge Fracture

Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

A retrospective cohort study published in BMC Musculoskeletal Disorders reports that open-wedge distal tibial tuberosity osteotomy (OWDTO) leads to a significant increase in tibial torsion angle under weight-bearing conditions, but this rotational change occurs only in knees that do not sustain a hinge fracture during the procedure. The research, conducted by a team including Jun Tomura and Muneaki Ishijima, utilized the EOS imaging system to evaluate rotational alignment before and after surgery in 63 subjects. The findings suggest that the integrity of the bone hinge may be a critical factor in determining postoperative rotational outcomes, although the clinical significance of these changes remains unclear.

The study aimed to assess how OWDTO affects the rotational alignment of the lower extremity. Specifically, the researchers focused on two primary rotational parameters: the femorotibial rotation angle (FTRA) and the tibial torsion angle (TTA).

The cohort consisted of 63 knees from 63 subjects who underwent OWDTO. In addition to the EOS imaging data, the team utilized CT scans performed one week after surgery to evaluate specific surgical parameters. These included the correction angle, the tibial osteotomy angle, and the presence or absence of a hinge fracture. Clinical outcomes were also assessed using the Knee injury and Osteoarthritis Outcome Score (KOOS) at both preoperative and six-month postoperative intervals.

The primary results indicated that the femorotibial rotation angle did not show a statistically significant change following the procedure. Preoperative FTRA was measured at 0.6 ± 4.0 degrees, while postoperative FTRA was -0.3 ± 3.6 degrees, with a p-value of 0.215. This suggests that the overall rotational relationship between the femur and tibia remained relatively stable. In contrast, the tibial torsion angle increased significantly. The mean TTA rose from 21.1 ± 6.7 degrees preoperatively to 23.5 ± 6.7 degrees postoperatively, with a p-value of less than 0.001. This increase indicates a shift toward external tibial torsion, meaning the tibia rotated outward relative to its original position.

When the researchers analyzed the association between rotational changes and other parameters, they found that the change in TTA was not significantly associated with changes in coronal alignment or other radiological parameters.

A critical finding emerged when the data were stratified by the presence of hinge fractures. In the group of knees without hinge fractures, the TTA increased significantly, with a mean change of 3.4 ± 3.2 degrees (p < 0.001). However, in the group with hinge fractures, no statistically significant change in TTA was detected, with a mean change of -0.2 ± 2.9 degrees (p = 0.491). Multivariable linear regression analysis confirmed that hinge fracture remained significantly associated with the change in TTA, even after adjusting for other variables.

Despite the significant radiological changes in tibial torsion, the study did not find a statistically significant association between the change in TTA and changes in KOOS subscale scores after adjusting for multiple comparisons. This indicates that while the surgery alters the rotational alignment of the tibia, this change does not necessarily translate into measurable improvements or declines in patient-reported clinical outcomes within the six-month follow-up period.

The authors note that while hinge integrity is associated with postoperative rotational changes, the clinical significance of these changes remains unclear.

Subject of Research: Rotational alignment changes after open-wedge distal tibial tuberosity osteotomy

Article Title: Evaluation of rotational alignment in open wedge distal tibial tuberosity osteotomy using the EOS imaging system: a retrospective cohort study

Article References: Tomura, J., Kim, Y., Arita, H., Shiozawa, J., Hada, S., Yoshida, K., Kobayashi, K., Kaneko, H., Saita, Y., Kubota, M., & Ishijima, M. (2026). Evaluation of rotational alignment in open wedge distal tibial tuberosity osteotomy using the EOS imaging system: a retrospective cohort study. BMC Musculoskeletal Disorders. https://doi.org/10.1186/s12891-026-10629-y

Image Credits: AI Generated

DOI: 10.1186/s12891-026-10629-y

Keywords: open-wedge distal tibial tuberosity osteotomy, tibial torsion angle, femorotibial rotation angle, EOS imaging system, hinge fracture, retrospective cohort study, weight-bearing alignment, Knee injury and Osteoarthritis Outcome Score, coronal alignment, tibial osteotomy angle, external tibial torsion, musculoskeletal disorders, postoperative rotational alignment, clinical outcomes assessment, surgical complication analysis

News Source: Ophelia Keating. (November 12, 2026). Tibial Torsion Increases After Osteotomy Only Without Hinge Fracture. Scienmag.

Tags: clinical outcomes assessmentcoronal alignmentEOS imaging systemexternal tibial torsionfemorotibial rotation anglehinge fractureknee injury and osteoarthritis outcome scoremusculoskeletal disordersopen-wedge distal tibial tuberosity osteotomypostoperative rotational alignmentretrospective cohort studysurgical complication analysistibial osteotomy angletibial torsion angleweight-bearing alignment
Share12Tweet7Share2ShareShareShare1

Related Posts

Hepatic Usp2 Promotes Lipid Accumulation Through G3bp2 Protein Stabilization

Hepatic Usp2 Promotes Lipid Accumulation Through G3bp2 Protein Stabilization

November 16, 2026
Preclinical Advancements in Transcranial Stimulation Techniques for Neuropsychiatric Disorder Treatment

Preclinical Advancements in Transcranial Stimulation Techniques for Neuropsychiatric Disorder Treatment

November 16, 2026

Interprofessional Virtual Reality Training PAVIN Demonstrates Feasibility in Paediatric Emergency Pilot

November 16, 2026

Medical Training Stage Linked to Preferred Social Media Platforms and Academic Use

November 16, 2026

POPULAR NEWS

  • Urban Expansion Across Sub-Saharan Africa Fuels Complex Malaria Transmission Risks

    Urban Expansion Across Sub-Saharan Africa Fuels Complex Malaria Transmission Risks

    29 shares
    Share 12 Tweet 7
  • Distinct Nesprin Isoforms Govern Nuclear Positioning and Mechanics in Striated Muscle

    29 shares
    Share 12 Tweet 7
  • Language Model Simulation Links Control Prompts to Synthetic Quiet Quitting Risk

    29 shares
    Share 12 Tweet 7
  • Standardized Metrics Needed to Prioritize Own Mother’s Milk in Neonatal Units

    29 shares
    Share 12 Tweet 7

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

Hepatic Usp2 Promotes Lipid Accumulation Through G3bp2 Protein Stabilization

Thymol and Carvacrol Reduce Diarrhea in Goat Kids by Supporting Gut Barriers

Amazonian Biodiversity Offers Pathways Toward Sustainable and Circular Global Food Systems

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 88 other subscribers
  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.