A retrospective investigation conducted at an Australian tertiary nuclear medicine centre indicates that electrons emitted within the bloodstream account for an average of 84.3 percent of the total blood-absorbed radiation dose during pre-therapy evaluations for differentiated thyroid cancer. In targeted radioiodine therapy using iodine-131, clinical specialists strive to deliver the maximum tumoricidal dose while strictly observing a safety ceiling for marrow exposure, commonly defined as a blood-absorbed dose of two grays under European Association of Nuclear Medicine standard procedures. Establishing this personalized threshold traditionally demands both sequential nuclear imaging and repeated venous blood sampling to track how radioiodine clears through the body over several days. When operational obstacles disrupt serial blood sampling, medical physicists are frequently forced to fall back on generic fixed administered activities or imaging-only dose estimates that lack explicit uncertainty boundaries. By analyzing paired serial imaging and blood measurements, the research establishes a cohort-derived electron blood self-dose fraction of 84.3 percent alongside an analytical framework that characterizes the unavoidable mathematical uncertainties introduced when blood measurements are omitted.
Personalized pre-therapy dosimetry aims to compute an administered therapy activity of iodine-131 that delivers a targeted absorbed dose to the blood, acting as an established surrogate for toxicity to the hematopoietic bone marrow. In standard clinical practice, this personalized protocol stands in direct contrast to empirical regimens that prescribe fixed activities between 100 and 150 millicuries, or 3.7 to 5.5 gigabecquerels, without tailoring for individual clearance rates. The standard dosimetric reference framework separates the blood-absorbed dose per unit administered activity into two distinct physical components described by Lassmann’s two-term formulation. The first component is the electron self-dose, or beta contribution, which represents energy deposited directly within circulating blood by beta particles and requires physical venous blood counting to evaluate accurately. The second component is the photon cross-fire, or gamma contribution, which accounts for radiation emitted from whole-body retention traversing into the bloodstream and can be derived directly from whole-body quantitative imaging and patient body mass.
Although serial blood draws represent the standard of care for individual dose personalization, maintaining an uninterrupted sampling schedule presents recurring logistical difficulties in routine outpatient hospital care. Unusable samples, scheduling conflicts surrounding clinic appointments, laboratory handling failures, and acute patient illness frequently cause patients to reach the therapy planning phase with missing or corrupted blood biomarker records. When venous counts are entirely absent, treatment teams must decide whether to abandon individualized prescribing altogether or infer the blood dose solely from whole-body clearance data. Generating a blood-dose estimate from imaging alone requires assuming a fixed electron self-dose fraction, denoted as beta fraction, to approximate the unmeasured blood clearance component. Early literature suggested that roughly 75 to 80 percent of the total blood dose stems from this electron self-dose mechanism, but this historical range was never paired with a formal, propagated statistical uncertainty metric.
To establish an evidence-based cohort reference and evaluate its associated error, researchers conducted a retrospective analysis of consecutive patients treated between 2018 and 2025 under institutional ethics oversight. The departmental archive originally contained 35 pre-therapy dosimetry procedures across 23 patients who received oral tracer doses of iodine-124 sodium iodide. Following systematic quality control, 15 courses were excluded due to absent paired venous blood data, which are mathematically indispensable for separating the total absorbed dose into its independent electron and photon terms. Among the remaining candidates, three procedures in two individuals were disqualified because automated body-contour segmentation yielded roughly one-third of the manually verified activity, and one additional course was excluded for providing fewer than three evaluable measurement points. The final analytical group comprised 18 fully evaluable dosimetry courses across 15 patients with differentiated thyroid cancer, consisting of eleven female and four male patients, including three pediatric individuals under eighteen years of age.
All patients in the study group underwent thyroid hormone withdrawal as their standard preparation regimen prior to the administration of an oral iodine-124 pre-therapy tracer activity ranging from 37 to 97 megabecquerels, with a median of 59.0 megabecquerels. Whole-body positron emission tomography and computed tomography scans were acquired using Siemens Biograph 20 mCT and 64 mCT scanners over an axial distance of approximately 1.85 meters from the skull vertex to the feet. Scanners operated with an energy window between 435 and 650 kiloelectronvolts, and images were reconstructed on the scanner console with time-of-flight technology, point-spread-function modeling, prompt gamma correction, and Gaussian filtering. Segmented whole-body activity was quantified using a shell-to-peak threshold contour method that matched manual delineations within two percent on validation subsets, while contemporaneous low-dose non-contrast computed tomography scans supplied anatomical localization and attenuation correction. Scan measurements were decay-corrected from the measured iodine-124 emission timeline into the therapeutic iodine-131 frame.
Venous blood specimens measuring approximately two milliliters were collected alongside imaging sessions against a clinical protocol targeting serial draws at nominal intervals of two, sixteen, forty, sixty-five, and ninety-six hours. One-milliliter aliquots were evaluated for two minutes within a sodium iodide well counter set to measure the 603 kiloelectronvolt gamma emissions of iodine-124 across an energy channel between 550 and 640 kiloelectronvolts. Count rates were converted to absolute activity by comparison against an aqueous reference standard prepared gravimetrically from the same calibrated tracer batch, canceling out systematic variations in counter sensitivity. Time-activity curves for both whole-body activity and blood concentration were fitted in the iodine-131 frame using mono-exponential regression models under standard professional operational procedures. The biological clearance constant was strictly bounded so that retention could never clear more slowly than the physical half-life of iodine-131, and residence times were computed directly by analytical integration of the fitted mono-exponential clearance curves.
Across the 18 evaluated therapy courses, the mean electron blood self-dose fraction was measured at 84.3 percent with a standard deviation of 4.8 percentage points, leaving a complementary photon cross-fire fraction of 15.7 percent. The median beta fraction reached 85.4 percent with an interquartile range between 81.8 and 87.6 percent, spanning an absolute range from 75.6 to 91.2 percent across all recorded procedures. When the data were aggregated to provide a single averaged value per patient across the 15 individuals, the beta fraction remained consistent at 84.4 percent with a standard deviation of 4.6 percentage points. The observed distribution of beta fractions passed statistical tests for normality, although histogram evaluation indicated a subtle bimodal appearance with potential clusterings near 77 percent and 87 percent that would require broader multi-centre cohorts to confirm. For the three individuals who underwent two distinct treatment courses, the within-patient dispersion was approximately 1.8 percentage points, substantially lower than the overall population variability.
An exploratory linear regression examining the relationship between the electron self-dose fraction and patient body weight identified a negative slope of minus 0.113 percentage points per kilogram across all 18 individual courses. This observed downward trend initially appeared statistically significant with a p-value of 0.019, predicting a beta fraction of roughly 89 percent at 40 kilograms and 80 percent at 120 kilograms. However, when the statistical analysis was collapsed to an average of one value per patient, the slope adjusted to minus 0.089 percentage points per kilogram and lost statistical significance with an unadjusted p-value of 0.118. This inverse trend runs counter to theoretical geometric expectations, which predict that heavier patients should exhibit smaller body-mass scaling factors on the photon cross-fire term and therefore demonstrate higher proportional beta fractions. Researchers noted that large inter-individual variations in biological residence times likely mask the subtle geometric influence of body weight in cohorts of this size.
When comparing the cohort’s overall pharmacokinetic performance against published international data, the median blood dose per unit administered activity was 0.205 grays per gigabecquerel, with an overall range spanning 0.093 to 0.640 grays per gigabecquerel. The whole-body residence time exhibited a cohort median of 31.5 hours and an interquartile range from 21.0 to 48.9 hours. These clearance metrics were evaluated against the international reference cohort published by Hänscheid and colleagues, which documented an average blood dose coefficient of 0.167 grays per gigabecquerel and a whole-body residence time of 24.1 hours in patients undergoing thyroid hormone withdrawal. While the Australian cohort’s median blood dose fell within one standard deviation of this established benchmark, individual course values exhibited broader biological spread, with ten of the eighteen procedures falling within the standard deviation band, seven measuring above it, and one registering below.
A critical analytical finding of the investigation involves the propagation of statistical uncertainty when replacing individual blood draws with an assumed cohort mean beta fraction. Differentiating the algebraic imaging-only estimator reveals that the fractional uncertainty on the resulting blood dose equals the standard deviation of the beta fraction divided by the quantity one minus the mean beta fraction. Because the mean beta fraction sits near 84.3 percent, the denominator acts as a geometric multiplier of roughly 6.4, amplifying the modest 4.8 percentage point standard deviation into an unavoidable relative uncertainty of approximately 30 percent on the estimated blood dose. This large margin of error stems directly from intrinsic human biological variation rather than technical imperfections in positron emission tomography detectors or scintillation counting equipment. Local imaging facilities can subsequently combine this biological substitution variance in quadrature with their own measured scanner-specific calibration and segmentation uncertainties.
To evaluate how the estimator performs in clinical simulation, the authors carried out leave-one-patient-out cross-validation by iteratively omitting each patient’s data and recalculating predictions from the remaining participants. The cross-validated evaluation demonstrated a mean absolute percentage error of 26.3 percent and a root-mean-square error of 32.7 percent, aligning closely with the 30.3 percent uncertainty predicted by first-order analytical propagation. Across all validation runs, 12 of the 18 therapy courses yielded estimated blood doses within plus or minus 30 percent of their true measured reference values, while individual percentage errors across the 2.5th to 97.5th percentiles ranged between minus 43 percent and plus 63 percent. Due to the mathematical convexity of reciprocal ratios, the mean ratio of true dose to estimated dose was 1.09, showing that unadjusted imaging-only estimates systematically underestimate the true absorbed dose to the blood by approximately nine percent.
Because systematically underestimating the absorbed dose per unit activity leads directly to over-prescribing radioactive iodine-131, safety margins cannot be established using standard symmetric confidence intervals. Instead, an allowable prescribing limit must be calculated strictly from the conservative lower tail of the relative error distribution to ensure marrow protection against the standard two-gray toxicity ceiling. Evaluating the fifth percentile of cross-validated estimation ratios yielded a value of 0.592, which corresponds to an allowable estimated dose ceiling of 1.18 grays, whereas assuming a normal distribution with 30.3 percent standard error produced an even lower cap of 1.00 gray. Based on these convergent bounds, the authors recommend that any clinical center implementing blood-free prescribing adopt an exploratory dose cap of roughly 1.0 to 1.2 grays. However, the authors emphasize that this cap represents a descriptive local observation derived from a small sample rather than a guideline-validated clinical threshold.
The study highlights several essential methodological boundaries that preclude immediate worldwide generalization of the reported numerical values. The investigation was conducted at a single medical center with a modest sample size of 18 courses in 15 patients, resulting in relatively wide confidence intervals and underscoring the urgent need for external multi-centre validation. Furthermore, none of the included patients reached the targeted nominal 96-hour imaging time-point, with the latest recorded scan occurring at 90.7 hours and the median final acquisition falling at 65.3 hours. Consequently, a median of 15 percent of the whole-body residence time and 14 percent of the blood residence time relied on mathematical extrapolation beyond the final empirical measurement, reaching up to 40 percent in less thoroughly sampled individuals. The authors also noted that the standard anthropomorphic photon constant used in the formulation was derived for average adult anatomy, introducing minor approximations when applied to pediatric patients and small individuals under 60 kilograms.
Ultimately, the researchers present the cohort beta fraction of 84.3 percent and its accompanying 30 percent uncertainty bound as an interim fallback protocol for clinical scenarios where physical blood draws are irrecoverably lost or clinically impossible. The mathematical formulation underlying this beta-gamma decomposition is fundamentally agnostic to imaging modalities, meaning that centers without positron emission tomography scanners could theoretically adapt the identical framework to quantitative low-dose iodine-131 single-photon emission computed tomography clearance studies, provided they account for the wider measurement uncertainties inherent to gamma camera quantification. The authors conclude that paired patient-specific serial blood sampling remains the essential gold standard for personalized radioiodine prescription, recommending that medical institutions characterize their own local cohort parameters and maintain strict prescribing caps whenever bloodless dosimetry must be deployed.
Subject of Research: Pre-therapy blood-marrow radiation dosimetry and uncertainty quantification in radioiodine therapy for differentiated thyroid cancer
Article Title: A cohort electron blood self-dose fraction and its propagated uncertainty for ¹²⁴I PET pre-therapy dosimetry in radioiodine therapy of differentiated thyroid cancer
Article References: Badawy, M., McIntosh, L., Jackson, P., & Jong, I. (2026). A cohort electron blood self-dose fraction and its propagated uncertainty for ¹²⁴I PET pre-therapy dosimetry in radioiodine therapy of differentiated thyroid cancer. Annals of Nuclear Medicine. https://doi.org/10.1007/s12149-026-02297-8
Image Credits: AI Generated
DOI: 10.1007/s12149-026-02297-8
Keywords: differentiated thyroid cancer, radioiodine therapy, iodine-124 PET, iodine-131 dosimetry, blood-marrow dosimetry, electron self-dose, photon cross-fire, time-activity curve, residence time, uncertainty propagation, cross-validation, thyroid hormone withdrawal, prescribing cap, radiation safety, nuclear medicine, pharmacokinetics, EANM guideline