• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Monday, November 23, 2026
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Technology

Salt Gradient Driven Phase Separation Creates Highly Durable Anticoagulant Device Coatings

by
November 23, 2026
in Technology
Reading Time: 6 mins read
0
Salt Gradient Driven Phase Separation Creates Highly Durable Anticoagulant Device Coatings

Salt Gradient Driven Phase Separation Creates Highly Durable Anticoagulant Device Coatings

Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

A newly reported surface modification strategy uses a sharp salt-concentration gradient to construct highly stable, antithrombotic coatings on blood-contacting substrates in a single processing step. Developed by a biomaterials engineering team, the technique harnesses spontaneous liquid–liquid phase separation of polyelectrolyte complexes across an aqueous interface, eliminating the tedious dipping cycles that constrain conventional multilayer assembly. When deposited onto polymeric substrates, the resulting coating retains approximately 73 percent of its functional heparin after 16 days of physiological incubation, while suppressing platelet adhesion by roughly 98 percent. In mammalian blood tests, the surfaces exhibited a negligible hemolysis rate of 0.32 percent, far below international safety thresholds. Subsequent ex vivo circulation assays demonstrated a 90 percent reduction in thrombus formation, presenting an efficient paradigm for functionalizing cardiovascular implants.

The innovation addresses a pervasive clinical challenge in vascular medicine, where synthetic blood-contacting devices frequently provoke surface-induced thrombosis and severe biofouling. Immobilizing heparin on material surfaces is a standard clinical method to improve hemocompatibility because this glycosaminoglycan binds antithrombin to block coagulation pathways. However, conventional fabrication methods face persistent trade-offs. Covalent grafting provides robust durability but demands harsh pretreatments, including plasma or ultraviolet activation, which complicate production and risk compromising heparin bioactivity. Conversely, electrostatic Layer-by-Layer assembly operates under mild processing conditions but remains tedious, requiring dozens of alternating deposition cycles while yielding limited heparin loading that restricts long-term performance.

To overcome these operational limitations, the researchers harnessed the equilibrium dynamics of polyelectrolyte complexes formed through spontaneous association of oppositely charged polymers. Counterions in solution exert a profound screening effect on these electrostatic interactions, enabling precise regulation over coacervate morphology. In four-molar sodium chloride, abundant sodium and chloride ions construct a dense electric double layer surrounding polymer chains. This ionic shielding weakens electrostatic attraction between cationic amine groups of polyethyleneimine and anionic sulfonic and carboxyl groups of heparin, preventing premature aggregation. Consequently, the dissociated macromolecular segments remain dispersed as a metastable, homogeneous precursor slurry. When surrounding salt concentration decreases, charge shielding dissolves rapidly, allowing strong electrostatic attractions to reactivate and driving polyelectrolytes to assemble into a dense coacervate.

The team blended polyethyleneimine solutions of two molecular weights, approximately 25,000 and 1,300 grams per mole, at a one-to-two volume ratio. This mixture was combined in equal volumes with a 50-milligram-per-milliliter heparin solution, followed by adding 50 percent hydrochloric acid to adjust pH to an acidic level and precipitate polyelectrolyte complexes. After centrifuging the suspension at 5,000 revolutions per minute for five minutes, researchers collected the precipitate and dissolved it completely in four-molar sodium chloride under vigorous stirring. The high ionic strength provided by the dissolved salt dismantled electrostatic complexes, yielding a stable, homogeneous high-salt precursor slurry ready for controlled interfacial assembly.

To evaluate coating efficacy on a clinically representative material, polylactic acid was selected as the primary deposition substrate due to its favorable processability. Polylactic acid specimens were first immersed in a two-milligram-per-milliliter dopamine solution buffered with 10 millimoles per liter of Tris at pH 8.5 for 45 minutes at room temperature. The substrates were subsequently treated for two hours with a solution containing 0.2 milligrams per milliliter of dopamine and 10 milligrams per milliliter of low-molecular-weight polyethyleneimine at pH 8.5.

Coating fabrication relied on establishing a macroscopic liquid–liquid phase separation boundary inside an assembly tube. Deionized water was introduced into the tube, and high-salt slurry was carefully injected into the bottom layer, creating a distinct interface. When the pretreated substrate was submerged into the slurry and withdrawn vertically upward into the water phase, the liquid film encountered an abrupt decrease in local ionic strength. Rapid interfacial diffusion of salt ions into bulk water eliminated charge shielding, reactivating electrostatic attraction between polyethyleneimine and heparin. Crucially, researchers noted that spontaneous coacervation is fundamentally driven by a significant entropic increase: as oppositely charged polymer chains associate, previously confined sodium and chloride counterions and hydration water molecules are expelled into solution, driving dense in situ network assembly.

Investigating the fluid dynamics of film deposition revealed that substrate withdrawal speed critically determines coating micromorphology. Governed by the Landau–Levich law, withdrawal velocity dictates viscous drag and the thickness of entrained precursor fluid. Testing withdrawal speeds of 1, 5, and 10 millimeters per second demonstrated that faster speeds failed to create continuous films, instead generating isolated, island-like coacervate clusters. Because salt acts as a plasticizer within polyelectrolyte matrices, rapid interfacial desalination at higher withdrawal speeds causes polymer chain relaxation times to increase exponentially, triggering sudden kinetic arrest before chains fully spread. These incompletely reorganized complexes dewet to minimize interfacial energy. Conversely, a lower withdrawal speed of one millimeter per second provided adequate time for chains to spread and form deep topological entanglements, yielding a continuous, uniform coating layer.

Spectroscopic and wettability analyses confirmed successful chemical incorporation of active heparin throughout the continuous polyelectrolyte matrix. Water contact angle measurements documented a sharp transition in surface hydrophilicity, shifting from approximately 83.98 degrees on bare polylactic acid down to 24.92 degrees on coated substrates, driven by abundant polar amino, carboxyl, and sulfonic groups. In Fourier-transform infrared spectroscopy, the modified substrate displayed a broad characteristic band at approximately 3500 reciprocal centimeters, assigned to overlapping stretching vibrations of amine and hydroxyl groups. A peak at 1590 reciprocal centimeters corresponded to stretching vibrations of amide or carboxylate groups within the backbone. Critically, an absorption peak appeared at approximately 937 reciprocal centimeters, corresponding to sulfate ester bond vibrations unique to heparin, confirming that the anticoagulant polysaccharide retained its functional molecular structure.

X-ray photoelectron spectroscopy quantitatively verified surface elemental distribution and chemical binding states across functionalized interfaces. Unmodified polylactic acid substrates displayed only carbon and oxygen peaks, whereas the phase-separated coating exhibited distinct nitrogen 1s and sulfur 2p signals, registering atomic percentages of 14.02 percent and 2.04 percent, respectively. High-resolution nitrogen 1s spectra revealed two deconvoluted peaks: an unprotonated amine component at 398.8 electron volts and a protonated amine peak at 400.7 electron volts. This positive charge confirmation demonstrates that polyethyleneimine maintains an elevated charge density, providing electrostatic attraction to anchor negatively charged heparin chains. In parallel, high-resolution sulfur 2p spectra displayed a characteristic doublet at 168.08 and 169.18 electron volts, corresponding to highly oxidized sulfur in heparin sulfonic acid groups, verifying that active anticoagulant motifs were effectively presented on the outer surface.

Long-term structural resilience under physiological conditions was quantitatively monitored by synthesizing a fluorescent heparin tracer labeled with Rhodamine B via carbodiimide chemistry. Doping the tracer into the formulation enabled tracking of heparin retention during dynamic incubation in phosphate-buffered saline at 37 degrees Celsius for 16 days. Fluorescence microscopy showed that while surface emission declined slightly due to early dissociation of loosely bound superficial molecules, the coating maintained continuous red fluorescence without macroscopic detachment. Optical density analysis confirmed an initial modest release, followed by a remarkably stable plateau. Heparin retention rates were measured at 84.24 percent on day three, 79.83 percent on day five, 76.42 percent on day seven, and approximately 72.89 percent after 16 days, proving that deep physical chain entanglements resist physiological shear and swelling.

In vitro hemocompatibility assays utilizing fresh rabbit blood further highlighted the coating’s biological safety and resistance to thrombogenesis. Hemolysis evaluations yielded a hemolysis rate of only 0.32 percent for the coated material, compared to 0.49 percent for untreated polylactic acid, resting substantially below the international clinical threshold of five percent. In parallel platelet adhesion experiments using platelet-rich plasma, scanning electron microscopy revealed that unmodified polylactic acid surfaces accumulated dense clusters of activated platelets exhibiting extensive pseudopodial spreading. In contrast, the phase-separated coating reduced platelet adhesion by approximately 98 percent, with few adherent cells retaining an unactivated, spherical morphology. This dramatic inhibition occurs because immobilized heparin specifically complexes with antithrombin in circulating plasma, accelerating inactivation of thrombin and factor Xa to arrest the coagulation cascade at its inception.

The therapeutic antithrombotic efficacy was established using an ex vivo extracorporeal circulation model in adult New Zealand white rabbits. Sample coatings were applied to flexible titanium foils, inserted into medical-grade catheters, and connected between the left jugular vein and right external carotid artery to form an arteriovenous shunt. Conversely, catheters protected with the phase-separated coating maintained continuous blood flow, achieving an approximate 90 percent reduction in thrombus weight and exhibiting only minimal, unaggregated erythrocytes. By demonstrating that salt-gradient phase separation rapidly forms durable, bioactive interfaces in a single immersion step, this study presents an efficient, scalable, and environmentally green platform for antithrombotic functionalization across diverse blood-contacting medical devices.

Subject of Research: One-step fabrication of stable antithrombotic polyelectrolyte coatings via salt-concentration-gradient-driven liquid–liquid phase separation.

Article Title: One-step fabrication of antithrombotic coating via salt-gradient-driven liquid–liquid phase separation

Article References: Wang, Z., Wang, Y., Luo, R., & Wang, Y. (2026). One-step fabrication of antithrombotic coating via salt-gradient-driven liquid–liquid phase separation. Surface Science and Technology, 4(1), Article 46. https://doi.org/10.1007/s44251-026-00154-4

Image Credits: AI Generated

DOI: 10.1007/s44251-026-00154-4

Keywords: Antithrombotic coatings, Liquid-liquid phase separation, Salt-concentration gradient, Heparin immobilization, Polyethyleneimine, Polyelectrolyte complexes, Hemocompatibility, Platelet adhesion suppression, Blood-contacting devices, Extracorporeal circulation, Arteriovenous shunt, Hemolysis testing, Antithrombin-III binding, Cardiovascular implants, Polylactic acid substrates, Dopamine surface functionalization, Interfacial coacervation, Landau-Levich film dynamics

News Source: Denise Maddox. (November 23, 2026). Salt Gradient Driven Phase Separation Creates Highly Durable Anticoagulant Device Coatings. Scienmag.

Tags: Antithrombin-III bindingAntithrombotic coatingsArteriovenous shuntBlood-contacting devicesCardiovascular implantsDopamine surface functionalizationextracorporeal circulationhemocompatibilityhemolysis testingHeparin immobilizationInterfacial coacervationLandau-Levich film dynamicsliquid-liquid phase separationPlatelet adhesion suppressionPolyelectrolyte complexespolyethyleneiminePolylactic acid substratesSalt-concentration gradient
Share12Tweet7Share2ShareShareShare1

Related Posts

Diffraction Aberration Correction Outperforms Ray Tracing in Transcranial Focused Ultrasound Simulations

Diffraction Aberration Correction Outperforms Ray Tracing in Transcranial Focused Ultrasound Simulations

November 23, 2026
Strict Land Constraints Reshape China's Clean Power Portfolios and Siting Costs

Strict Land Constraints Reshape China’s Clean Power Portfolios and Siting Costs

November 23, 2026

Minkowski Image Loss Embeds Geometric Invariants Into Deep Learning for Radar Precipitation

November 23, 2026

Audience Machine Heuristic Beliefs Drive Credibility Ratings in Artificial Intelligence Journalism

November 23, 2026

POPULAR NEWS

  • Clinical Trial Standardizes Multi-Center Protocol Testing Herbal Formula for Carotid Plaque

    Clinical Trial Standardizes Multi-Center Protocol Testing Herbal Formula for Carotid Plaque

    29 shares
    Share 12 Tweet 7
  • Plasma Protein Network Shows Divergent Cognitive Links in Cerebrospinal Fluid

    29 shares
    Share 12 Tweet 7
  • COVID-19 Surges Temporarily Cut Hospital Outpatient Therapy for Chronic Neurological Conditions

    29 shares
    Share 12 Tweet 7
  • Cardiovascular Disease Epidemiology Pioneer Henry Blackburn Dies at Age 101

    29 shares
    Share 12 Tweet 7

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

Diffraction Aberration Correction Outperforms Ray Tracing in Transcranial Focused Ultrasound Simulations

Pulsed Radiofrequency of Greater Occipital Nerve Associated With Reduced Cervical Myofascial Pain

Strict Land Constraints Reshape China’s Clean Power Portfolios and Siting Costs

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 88 other subscribers
  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.