• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Saturday, December 27, 2025
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Chemistry

Cyborg-like microchip valve driven by earthworm muscle

Bioengineer by Bioengineer
July 9, 2019
in Chemistry
Reading Time: 3 mins read
0
Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

Credit: RIKEN

Scientists at the RIKEN Center for Biosystems Dynamics Research (BDR) in Japan have developed the first microchip valve powered by living cells. Earthworm muscle tissue allowed for a high contractile force that could be sustained for minutes, and unlike electrically controlled valves, did not require any external power source such as batteries.

For several decades, researchers have been trying to combine microelectromechanical systems (MEMS) with living material. Bio-MEMS have many applications, ranging from improved drug delivery and optical and electrochemical sensors to organs-on-chips. The team of researchers from RIKEN BDR and Tokyo Denki University have been developing a bio-MEMS that is driven by real muscle, which could be useful in surgical implants. Building on their on-chip micropump design, the new study is the proof-of-concept for an on-chip muscle-driven valve.

In mechanics, an actuator is the part of a machine that controls a mechanism by making it move, such as the opening and closing of a valve. Actuators require a power source and a control signal, which are typically electric current or some kind of fluid pressure. The main advantage for using muscles as actuators in bio-MEM systems is that they can be powered the same way as they are in living bodies: chemically. For muscles, the signal for contraction is the molecule acetylcholine–which is delivered by neurons–and the energy source is adenosine triphosphate (ATP)–which exists inside muscle cells.

“Not only can our bio-MEMS work without an external power source, but unlike other chemically driven valves that are controlled by acids, our muscle-driven valve runs on molecules that are naturally abundant in living organisms,” says first author Yo Tanaka from RIKEN BDR. “This makes it bio-friendly and especially suited for medical applications in which the use of electricity is difficult or not advised.”

The team initially determined that a small 1 cm × 3 cm sheet of earthworm muscle could produce an average contractile force of about 1.5 milli-newtons over a 2-min period when stimulated by a very small amount of acetylcholine. Using this data, they build a microfluid channel and valve on a 2 cm × 2 cm microchip that could be controlled by the contraction/relaxation of earthworm muscle.

To test the system, they used a microscope to monitor fluorescently labeled microparticles in liquid as they flowed through the microchannel. When acetylcholine was applied, the muscle contacted. The resulting force was transduced to a bar that was pushed down to close the valve, which successfully stopped the flow of liquid. When the acetylcholine was washed away, the muscle relaxed, the valve re-opened, and the fluid flowed again.

“Now that we have shown that on-chip muscle-driven valves are possible, we can work on improvements that will make it practical,” says Tanaka. “One option is to use cultured muscle cells. This might enable mass-production, better control, and flexibility in terms of shape. However, we will have to account for the reduction in the amount of force that can be produced this way compared with real muscle sheets.”

###

The study was published in Scientific Reports on July 8.

Reference: Tanaka Y, Funano S, Noguchi Y, Yalikun Y, Kamamichi N (2019) A valve powered by earthworm muscle with both electrical and 100% chemical control. Scientific Reports. doi: 10.1038/s41598-019-44116-3

Media Contact
adam phillips
[email protected]

Related Journal Article

http://dx.doi.org/10.1038/s41598-019-44116-3

Tags: BiologyBiotechnologyMechanical EngineeringNanotechnology/MicromachinesTechnology/Engineering/Computer Science
Share12Tweet8Share2ShareShareShare2

Related Posts

Cutting Electrolyte Reduction Boosts High-Energy Battery Performance

Cutting Electrolyte Reduction Boosts High-Energy Battery Performance

December 19, 2025
Microenvironment Shapes Gold-Catalysed CO2 Electroreduction

Microenvironment Shapes Gold-Catalysed CO2 Electroreduction

December 11, 2025

Photoswitchable Olefins Enable Controlled Polymerization

December 11, 2025

Cation Hydration Entropy Controls Chloride Ion Diffusion

December 10, 2025
Please login to join discussion

POPULAR NEWS

  • Robotic Waist Tether for Research Into Metabolic Cost of Walking

    NSF funds machine-learning research at UNO and UNL to study energy requirements of walking in older adults

    71 shares
    Share 28 Tweet 18
  • Nurses’ Views on Online Learning: Effects on Performance

    70 shares
    Share 28 Tweet 18
  • Exploring Audiology Accessibility in Johannesburg, South Africa

    51 shares
    Share 20 Tweet 13
  • Unraveling Levofloxacin’s Impact on Brain Function

    55 shares
    Share 22 Tweet 14

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

Advancements in Computerized Liver Tumor Ablation Planning

Pilot Study: Haptic VR Simulation for Nursing Students

Unraveling Bisphenol A’s Stroke Toxicity Mechanisms

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 71 other subscribers
  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.