• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Thursday, November 19, 2026
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Technology

Core–Shell Elastomeric Fibers Improve Mechanical Stability in Wearable Strain Sensors

by
November 7, 2026
in Technology
Reading Time: 2 mins read
0
Core–Shell Elastomeric Fibers Improve Mechanical Stability in Wearable Strain Sensors

Core–Shell Elastomeric Fibers Improve Mechanical Stability in Wearable Strain Sensors

Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

Researchers have fabricated core–shell structured conductive elastomeric fibers, designated as TGWs, to improve the mechanical stability and wearability of flexible textile strain sensors. The development addresses a persistent challenge in wearable sensing technology, where achieving desirable sensing performance often compromises the mechanical elasticity of highly elastic textile substrates. In the reported design, conductive coatings composed of graphene and waterborne polyurethane are applied onto thermoplastic polyamide elastomer fiber cores. The resulting composite fibers offer an integrated architecture intended to preserve flexibility while establishing reliable electrical pathways for strain detection.

The manufacturing strategy relies on surface modification and coating techniques to secure the conductive shell onto the elastomeric base. Specifically, thermoplastic polyamide elastomer fibers undergo an ethanol surface treatment followed by ultrasonic impregnation to deposit the graphene and waterborne polyurethane conductive layer. Following fiber fabrication, the team constructed a series of flexible strain sensors, labeled TGW1 through TGW5, by incorporating the core–shell conductive fibers into PGW-5 fabrics using stitching methods.

Systematic characterization showed that the TGW conductive elastomeric fibers retain high mechanical resilience and durability under repeated physical stress. At a constant tensile elongation of 50 percent, the fibers demonstrated an elastic recovery rate of 94.7 percent. The fibers also exhibited notable resilience against simulated laundering and mechanical abrasion, retaining more than 90 percent of their electrical conductivity after 20 washing cycles and enduring 200 friction cycles with resistance fluctuations remaining below 13 percent, confirming their initial operational stability.

When evaluated in integrated fabric assemblies, the stitched strain sensors delivered measurable improvements in mechanical performance relative to unmodified textiles. Notably, the TGW5 sensor configuration enhanced elastic recovery by 19.3 percent compared with the pristine fabric substrate after stitching.

In addition to improved elasticity, the sensor maintained functional moisture management necessary for practical wearable devices. The TGW5 fabric sensor exhibited a water vapor transmission rate of 5.06 kilograms per square meter per day, demonstrating that the inclusion of the TGW fibers does not significantly compromise breathability or wearability-related properties. The authors conclude that this core–shell fiber fabrication strategy provides a feasible engineering approach for designing textile-based strain sensors with potential utility in wearable sensing applications.

Subject of Research: Flexible strain sensors based on core–shell conductive elastomeric fibers

Article Title: Fabrication of flexible strain sensors based on core–shell conductive elastomeric fibers for improved mechanical stability and wearability-related properties

Article References: Zhao, W., Zhang, Z., Xie, X., & Zhang, X. (2026). Fabrication of flexible strain sensors based on core–shell conductive elastomeric fibers for improved mechanical stability and wearability-related properties. Journal of Materials Science. https://doi.org/10.1007/s10853-026-13967-3

Image Credits: AI Generated

DOI: 10.1007/s10853-026-13967-3

Keywords: flexible strain sensors, conductive fibers, core-shell fibers, wearable electronics, graphene, elastomeric textiles, smart fabrics, sensor durability, Fabrication, flexible, strain, sensors

News Source: Denise Maddox. (November 7, 2026). Core–Shell Elastomeric Fibers Improve Mechanical Stability in Wearable Strain Sensors. Scienmag.

Tags: conductive fiberscore-shell fiberselastomeric textilesfabricationflexibleflexible strain sensorsgraphenesensor durabilitysensorssmart fabricsstrainwearable electronics
Share12Tweet7Share2ShareShareShare1

Related Posts

Swarm Optimization Framework Improves Flying Ad Hoc Network Energy and Routing Lifetime

Swarm Optimization Framework Improves Flying Ad Hoc Network Energy and Routing Lifetime

November 19, 2026
German Radiology Corpus Advances Automated Information Extraction for Urinary Stone Diagnostics

German Radiology Corpus Advances Automated Information Extraction for Urinary Stone Diagnostics

November 19, 2026

Adaptive Adversarial Network Boosts Seismic Fault Identification Accuracy Across Surveys

November 19, 2026

Combined Carbonation and Water Curing Densifies CO2-Injected Model Concrete Matrices

November 19, 2026

POPULAR NEWS

  • Tryptophan Can Contribute to Seawater Iron Reduction at Lower pH

    Tryptophan Can Contribute to Seawater Iron Reduction at Lower pH

    29 shares
    Share 12 Tweet 7
  • Preserving Cervical Carotid Segments During Autopsy May Facilitate Subsequent Facial Embalming

    29 shares
    Share 12 Tweet 7
  • Adaptive Adversarial Network Boosts Seismic Fault Identification Accuracy Across Surveys

    29 shares
    Share 12 Tweet 7
  • Prenatal Testing Identifies Rare Mosaic Trisomy 14 in Early Severe Fetal Malformations

    29 shares
    Share 12 Tweet 7

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

Uropathogens Colonize 27.6 Percent of Diabetic Patients in Ghanaian Hospital Study

Machine Learning Reveals Discordance Between Infective Endocarditis Mortality Risk and Surgical Use

Early DIP Payment in Inner Mongolia Linked to Suggestive Procedure-Intensity Changes

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 88 other subscribers
  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.