• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Wednesday, November 25, 2026
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Biology

Curve Registration Enhances Soft Sensor Recalibration Accuracy in Microbial Fermentations

by
November 25, 2026
in Biology
Reading Time: 6 mins read
0
Curve Registration Enhances Soft Sensor Recalibration Accuracy in Microbial Fermentations

Curve Registration Enhances Soft Sensor Recalibration Accuracy in Microbial Fermentations

Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

A comparative study evaluating data synchronization techniques for automated soft sensor recalibration has shown that curve registration significantly improves prediction performance in bioprocesses, while dynamic time warping struggles due to mathematical singularities. Published in Biotechnology and Bioprocess Engineering by Manuel Siegl and colleagues, the research examined soft sensors used to estimate key cultivation variables that lack dependable real-time hardware instrumentation. By aligning historical process data with active fermentations prior to model calibration, curve registration reduced prediction error by an average of 24 percent for biomass in Pichia pastoris and 9 percent for protein in Bacillus subtilis. Conversely, dynamic time warping produced negligible improvement in yeast runs and deteriorated accuracy in bacterial fermentations, underscoring the risks of non-linear signal warping during variable process kinetics.

Biotechnological manufacturing depends on continuous surveillance to optimize production, yet primary operational indicators such as biomass and product concentrations cannot be monitored continuously with standard hardware. Industrial bioprocesses bridge this gap with soft sensors, which blend online hardware measurements—including pH, dissolved oxygen, temperature, and off-gas concentrations—into mathematical models based on statistical relationships and process understanding. Previous implementations have successfully predicted biomass in Pichia pastoris, estimated insulin formation in Escherichia coli, and tracked metabolites in Clostridium butyricum. Nonetheless, living cultures experience changing raw material qualities, biological variability, and evolving process strategies that alter underlying system relationships over time. Without regular recalibration, soft sensor models inevitably suffer severe accuracy degradation, making automated just-in-time recalibration frameworks an essential alternative to time-consuming manual intervention.

Automated recalibration frameworks maintain soft sensor reliability by retrieving relevant historical runs from a data repository when recalibration triggers occur. Because physical reference analyses from ongoing batches arrive only after laboratory delays, recalibration relies entirely on historical data. Selecting batches through distance-based similarity within a multiway principal component analysis space outperforms chronological selection, particularly during unexpected operating shifts. However, distance-based selection often falters when historical fermentations exhibit differing lag durations or shifted growth landmarks. Under simple Euclidean metrics, algorithms tend to select historical batches possessing identical lag lengths rather than relevant physiological trajectory patterns across active growth phases. Synchronizing historical curves to align landmark locations with the current fermentation resolves this limitation, allowing similarity metrics to evaluate biological shape patterns rather than arbitrary temporal shifts.

To determine an effective temporal alignment technique, the authors compared dynamic time warping and curve registration. A third technique, indicator variable modeling, employs non-temporal markers such as maturity indices to normalize process length; however, because it aligns only total run duration rather than internal biological landmarks, it was omitted from consideration. Dynamic time warping operates as an iterative algorithm that calculates pairwise Euclidean distances between points in a query batch and historical datasets, determining a warping path that minimizes cumulative distances by skipping or duplicating values while prohibiting backward steps. In contrast, curve registration views sensor trajectories as continuous functions. It identifies characteristic structural landmarks, such as local extrema and turning points, directly matching these features between batches while uniformly stretching or compressing the intervening regions.

The experimental framework investigated two distinct biological cultivation regimes, starting with a 15-liter culture of Pichia pastoris strain DSMZ 70382 in a 42-liter Sartorius Biostat Cplus bioreactor. Inoculum preparation pooled three shake flasks cultivated for 70 hours in FM22 medium with glycerol at 30 degrees Celsius. Reactor conditions were maintained at 30 degrees Celsius, pH 5, 500 millibars pressure, and 40 percent dissolved oxygen. After initial glycerol exhaustion, fed-batch feeding commenced using methanol supplemented with PTM4 trace salts. BlueSens sensors recorded off-gas carbon dioxide and oxygen, while an Alcosens probe tracked methanol under SIMATIC SIPAT logging. Reference dry cell weight measurements were conducted in triplicates every 2 to 14 hours by centrifuging samples at 21,000 times gravity and drying pellets at 80 degrees Celsius for 72 hours.

To evaluate algorithmic versatility across diverse organisms, the researchers examined an industrial Bacillus subtilis process producing commercial protein. Conducted in 1.4-liter Infors Multifors bioreactors with 700-milliliter working volumes, cultivations utilized a proprietary high-performance medium developed by Clariant Produkte GmbH. Glucose served as the primary carbon substrate, supplied during initial batch growth and subsequently fed under diverse operational profiles with constant aeration of 1.5 liters per minute. Exhaust gas compositions were monitored continuously using a Thermo Scientific Prima PRO mass spectrometer, with process control managed via eve software. The target variable was active protein concentration, measured offline in triplicates using enzymatic activity assays. Marked by substantial feeding differences across runs, this 24-batch dataset provided a demanding industrial test bed characterized by significant process variability.

Model development in MATLAB R2023a incorporated both measured online variables and derived metabolic rates as inputs. Calculations yielded carbon dioxide evolution rates and oxygen uptake rates using airflow rates, pressure, temperature, universal gas constant, and inlet and outlet gas mole fractions, supported by liquid volume balances accounting for feeds and sampling. Cumulative gas exchange trajectories were also included. To select calibration runs matching active fermentations, three-dimensional batch matrices were refolded into two-dimensional arrays for multiway principal component analysis. Scores from the first four principal components, weighted by explained variance, established a noise-reduced search space. The algorithm computed weighted Euclidean distances between the query process and historical data, selecting the three nearest neighbors as calibration candidates across four scheduled recalibration points per run.

Following batch selection, partial least squares regression calibrated linear soft sensor models by constructing latent variables that captured covariance with reference measurements. Model dimensionality was optimized by selecting the number of latent variables matching the first local minimum of mean squared error. To prevent sharp output discontinuities between consecutive models, the algorithm implemented a smooth transition using a linear forgetting factor. Over a transition window covering the first 40 percent of the interval between recalibrations, this factor decreased linearly from one to zero, gradually blending prior model estimates into the recalibrated model. Predictive performance across all validation runs was systematically quantified using the normalized root mean squared error of prediction, establishing an objective benchmark to compare unsynchronized models against variants using dynamic time warping or curve registration.

Both synchronization methods incorporated specific adaptations to handle bioprocess complexity. For dynamic time warping, variables were scaled by average ranges before iterative alignment; historical data were aligned to query batches for three iterations and subsequently matched to running mean curves. To prevent mathematical instability, iterations were capped at 20, convergence checked, and candidate runs restricted to ten batches preselected via multiway principal component analysis. For curve registration, principal component analysis reduced multivariate query signals into a primary score trajectory. The Pruned Exact Linear Time algorithm then identified structural shifts in trajectory slope and mean to detect landmarks. Enforcing minimum distance rules between landmarks yielded ten features per run for Pichia pastoris and six for Bacillus subtilis, linearly stretching or compressing intervening intervals.

Across the twelve-batch Pichia pastoris dataset, curve registration generated significant improvements in biomass prediction accuracy. Soft sensors without synchronization yielded an average normalized root mean squared error of 13.5 percent. Preprocessing with dynamic time warping lowered error marginally to 13.0 percent, representing an average improvement of only 4 percent. In contrast, curve registration reduced average error to 10.3 percent, achieving a substantial 24 percent accuracy enhancement. Trajectory evaluations revealed that while batch phases exhibited minimal divergence up to hour 37, temporal shifts emerged during the fed-batch methanol phase. Dynamic time warping altered curve shapes excessively through value duplication, discarding valuable information. Curve registration preserved underlying physiological profiles while successfully aligning fed-batch landmarks, eliminating the severe prediction overestimates that degraded unsynchronized models between hours 45 and 63.

In the 24-batch Bacillus subtilis trial, dynamic time warping experienced severe breakdown, whereas curve registration maintained predictive superiority. Unsynchronized models produced an average normalized error of 17.4 percent for protein concentration, which curve registration reduced to 15.9 percent, achieving a 9 percent accuracy improvement. Conversely, dynamic time warping deteriorated performance, raising average error to 20.7 percent. This degradation occurred because diverse feeding strategies created substantial amplitude disparities, doubling carbon dioxide output between certain batches. When aligning curves with large amplitude differences, dynamic time warping generated extensive singularities, excessively duplicating individual points past 30 percent process completion. The resulting loss of information led soft sensors to produce biologically implausible trajectories, including an artificial decrease in protein concentration between 55 and 80 percent duration despite stable respiration.

Both synchronization techniques transferred readily between different bioprocesses, yet curve registration proved decisively superior for soft sensor recalibration. Although dynamic time warping required no manual landmark parameterization, its vulnerability to persistent amplitude variations caused substantial information loss under shifting operational strategies. Curve registration avoided this failure mode by decoupling landmark timing from absolute signal magnitudes, maintaining true physiological trajectory profiles. The authors highlighted that future recalibration frameworks could integrate automated phase detection to replace fixed time intervals, ensuring that models calibrate across consistent metabolic regimes. Incorporating nonlinear architectures like neural networks and robust fault-detection algorithms could further bolster reliability. Ultimately, pairing curve registration with automated recalibration and regularly updated batch repositories provides a scalable strategy to ensure the long-term industrial viability of bioprocess soft sensors.

Subject of Research: Data synchronization methods for automated recalibration of bioprocess soft sensors

Article Title: Data synchronization techniques and their impact on the prediction performance of automated recalibrated soft sensors in bioprocesses

Article References: Siegl, M., Geier, D., Andreeßen, B., Max, S., Mose, E., Zavrel, M., & Becker, T. (2024). Data synchronization techniques and their impact on the prediction performance of automated recalibrated soft sensors in bioprocesses. Biotechnology and Bioprocess Engineering, 29(5), 929-941. https://doi.org/10.1007/s12257-024-00120-7

Image Credits: AI Generated

DOI: 10.1007/s12257-024-00120-7

Keywords: Soft Sensors, Curve Registration, Dynamic Time Warping, Automated Recalibration, Bioprocess Monitoring, Pichia pastoris, Bacillus subtilis, Multiway Principal Component Analysis, Partial Least Squares Regression, Biomass Prediction, Protein Concentration, Exhaust Gas Analysis, Oxygen Uptake Rate, Carbon Dioxide Evolution Rate, Pruned Exact Linear Time, Fermentation Kinetics

News Source: Morgan Morrow. (November 25, 2026). Curve Registration Enhances Soft Sensor Recalibration Accuracy in Microbial Fermentations. Scienmag.

Tags: Automated RecalibrationBacillus subtilisBiomass PredictionBioprocess MonitoringCarbon Dioxide Evolution RateCurve Registrationdynamic time warpingExhaust gas analysisfermentation kineticsMultiway Principal Component AnalysisOxygen Uptake Ratepartial least squares regressionPichia pastorisprotein concentrationPruned Exact Linear Timesoft sensors
Share12Tweet7Share2ShareShareShare1

Related Posts

Temperature Drop Activates RNA Reader to Halt Protein Synthesis in Malaria Parasites

Temperature Drop Activates RNA Reader to Halt Protein Synthesis in Malaria Parasites

November 25, 2026
Standardized Protocol Standardizes Assembly and Testing for Aqueous Organic Flow Batteries

Standardized Protocol Standardizes Assembly and Testing for Aqueous Organic Flow Batteries

November 25, 2026

Termites and Palm Weevils Lead Edible Insect Use in Southeastern Nigeria

November 25, 2026

Plant Virus Spillover Across Wild and Cultivated Interfaces Drives Viral Disease Emergence

November 25, 2026

POPULAR NEWS

  • Machine Learning Powers Electronic Noses for Food Freshness and Authenticity Assessment

    Machine Learning Powers Electronic Noses for Food Freshness and Authenticity Assessment

    29 shares
    Share 12 Tweet 7
  • Review Highlights Multimodal Diagnostic Strategies Amid Global Resurgence of Neurosyphilis

    29 shares
    Share 12 Tweet 7
  • Gallic Acid Metal Assemblies Deliver Tunable Nanoscale Redox Functions for Disease Therapies

    29 shares
    Share 12 Tweet 7
  • Clinical Trial Protocol Evaluates Yangxinshi Tablets for Incomplete Coronary Revascularization Chest Pain

    29 shares
    Share 12 Tweet 7

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

Simulations Predict β-Sitosterol Binds Near Tyr235 in Malarial Lactate Dehydrogenase

Stimulant Cravings and Earlier Initiation Weaken Treatment Motivation in Malaysian Youth

Aortic Plaque and Procedural Factors Predict Kidney Injury After Valve Replacement

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 89 other subscribers
  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.