• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Wednesday, November 25, 2026
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Health

Device Reprogramming Resolves Dual Arrhythmia and Competitive Pacing in Fabry Disease Case

by
November 25, 2026
in Health
Reading Time: 5 mins read
0
Device Reprogramming Resolves Dual Arrhythmia and Competitive Pacing in Fabry Disease Case

Device Reprogramming Resolves Dual Arrhythmia and Competitive Pacing in Fabry Disease Case

Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

A 60-year-old male patient diagnosed with Fabry disease complicated by hypertrophic cardiomyopathy presented to an emergency department with acute palpitations lasting 1.5 hours, accompanied by dizziness and chest tightness. His medical background was notable for an allogeneic kidney transplantation and the primary prevention implantation of a dual-chamber transvenous implantable cardioverter-defibrillator two years prior. The patient was actively taking a complex home pharmacotherapy regimen comprising beta-blockers, post-transplant immunosuppressants including cyclosporin and mycophenolate mofetil, enzyme replacement therapy with agalsidase beta, and heart failure medications including sacubitril/valsartan sodium tablets and diuretics.

Fabry disease is a rare X-linked lysosomal storage disorder caused by pathogenic variants in the gene encoding alpha-galactosidase A, situated on chromosome band Xq22.1. Deficiency or absence of alpha-galactosidase A enzymatic activity leads to impaired intracellular metabolism and subsequent systemic deposition of the glycosphingolipid substrate globotriaosylceramide within tissues. These structural and electrophysiological abnormalities frequently generate complex ventricular and supraventricular arrhythmias, prompting the surgical implantation of cardiac electronic devices that can present intricate diagnostic interactions during emergent acute rhythm disturbances.

Initial laboratory evaluations in the emergency department demonstrated an elevated serum troponin concentration of 0.060 ng/mL, a D-dimer level of 2,450 ng/mL, a venous blood glucose concentration of 10.18 mmol/L, and a normal serum potassium level of 4.19 mmol/L, with supplementary testing including complete blood counts, arterial blood gas analyses, liver panels, and C-reactive protein. Bedside transthoracic echocardiography documented an anteroposterior left atrial diameter of 43 mm, marked interventricular septal hypertrophy measuring 21 mm, a left ventricular end-diastolic diameter of 56 mm, a left ventricular end-systolic diameter of 45 mm, and a depressed left ventricular ejection fraction of 40 percent. Medical management commenced immediately upon admission, consisting of supportive stabilization, ten milligrams of intravenous diazepam, and an intravenous infusion of 150 mg of amiodarone, alongside urgent consultation with electrophysiology specialists for emergency device interrogation.

A 12-lead electrocardiogram recorded at 15:32:57 on September 19, 2024, captured a wide-QRS complex tachycardia at a rate of 142 beats per minute with a widened QRS duration of 200 milliseconds. The tracing displayed no identifiable P waves and demonstrated complete left bundle branch block morphology, characterized by positive R-wave deflections in leads I and aVL, deep QS complexes across leads II, III, and aVF with an R-wave peak time of 50 milliseconds or greater in lead II, and rS patterns throughout leads V1 through V6 with r-wave durations exceeding 40 milliseconds. The frontal QRS electrical axis revealed marked left-axis deviation at minus 49 degrees. Analysis according to the Vereckei aVR algorithm demonstrated an initial r wave wider than 40 milliseconds, a distinct notch on the descending limb of the QRS complex, and a Vi/Vt ratio below 1, yielding a VT score of three points consistent with ventricular tachycardia.

Careful inspection of the baseline 12-lead electrocardiogram revealed two distinct morphologies of cardiac pacing spikes operating alongside the underlying wide-QRS tachycardia. Upward atrial pacing artifacts possessing an amplitude of 0.3 millivolts were recorded 80 to 90 milliseconds prior to the 17th and 21st QRS complexes. In contrast, prominent ventricular pacing spikes with an amplitude of 0.8 millivolts appeared at the precise onset of the 3rd, 15th, and 19th QRS complexes, successfully capturing the ventricular myocardium with shortened R-R intervals compared to the baseline tachycardia. Furthermore, an isolated ventricular pacing spike delivered at the peak of the T wave of the 13th QRS complex failed to capture because the electrical impulse fell directly into the physiological ventricular effective refractory period, giving an initial outward appearance of competitive device pacing or automated hardware malfunction.

Emergency real-time interrogation of the patient’s Boston Scientific INOGEN model D142 dual-chamber cardioverter-defibrillator was conducted at 16:24:45 on September 19, 2024, utilizing intracardiac electrogram recordings and real-time marker channel displays. The atrial lead recorded electrogram signal intervals varying between 260 and 278 milliseconds, representing an atrial tachyarrhythmia with an intrinsic rate of 215 to 230 beats per minute diagnostic of ongoing atrial flutter. Concurrently, the right ventricular sensing lead registered variable ventricular intervals spanning 403 to 525 milliseconds, corresponding to an intrinsic ventricular rate of 114 to 148 beats per minute. Systematic review of marker sequences demonstrated absent fixed conduction timing between atrial flutter deflections and ventricular sensed events, establishing genuine atrioventricular dissociation.

The baseline programming parameters of the implanted dual-chamber device were configured to a primary DDD pacing mode with a lower rate limit of 60 beats per minute, a maximum tracking rate of 130 beats per minute, and programmed paced and sensed atrioventricular delays of 220 to 300 milliseconds. Pacing algorithms incorporated an active Atrial Tachycardia Therapy mode switch set to trigger at 170 beats per minute after eight consecutive cycles, directing automatic fallback to a non-tracking DDI mode at a lower rate limit of 60 beats per minute. Integrated within this fallback mode was an activated Ventricular Rate Regulation algorithm with a programmed maximum pacing rate of 130 beats per minute. Ventricular tachycardia detection zones had been previously programmed with a detection threshold of 160 beats per minute configured to deliver burst and scan antitachycardia pacing followed by serial tiered shocks, while the ventricular fibrillation detection zone was set at 220 beats per minute.

Device marker channel data revealed recurrent AP-VR and VP-VR annotations confirming the active operation of the proprietary Ventricular Rate Regulation algorithm during the atrial tachyarrhythmia. Ventricular Rate Regulation operates uniquely in Boston Scientific systems to stabilize ventricular cycle variability during partially conducted atrial arrhythmias by dynamically computing pacing intervals through a weighted moving average of antecedent V-V intervals. Because sensed intrinsic ventricular events prompt the algorithm to modestly elevate pacing output toward the maximum pacing rate, the calculated pacing rate transiently exceeded the intrinsic rhythm. Moreover, ventricular sensed events that occurred within the post-atrial pacing blanking period were excluded from the timing cycle, causing the device to deliver programmed atrioventricular interval pacing that fell harmlessly on the T wave without ventricular capture, clarifying the competitive pacing rhythm.

Because the patient’s ongoing ventricular tachycardia stabilized at a sustained rate of 142 beats per minute, the rhythm remained below the programmed 160 beats per minute threshold of the device’s ventricular tachycardia therapy zone, preventing automated therapeutic intervention. The electrophysiology team reprogrammed the device parameters by lowering the ventricular tachycardia detection rate to 140 beats per minute, bringing the clinical tachycardia into the active therapeutic zone. Upon immediate detection and confirmation using programmed supraventricular tachycardia discrimination algorithms, the defibrillator initiated programmed antitachycardia pacing sequences consisting of burst and scan delivery.

The mechanism of independent dual arrhythmia was corroborated by retrospective review of an earlier ventricular fibrillation episode stored on the defibrillator on May 31, 2024, which documented complete ventricular arrhythmia termination following antitachycardia pacing while atrial flutter persisted unabated, confirming persistent atrioventricular dissociation. In analyzing this complex presentation, the clinicians emphasized that dual-chamber defibrillator algorithms interacting with concomitant atrial and ventricular tachyarrhythmias can simulate device malfunction on surface electrocardiograms. The clinical authors recommended that for cardiomyopathy patients undergoing primary prevention cardioverter-defibrillator placement, programmers should consider adding dedicated slow ventricular tachycardia monitor zones to ensure early recognition, while disabling automated ventricular rate regularization algorithms during atrial arrhythmias to prevent competitive ventricular pacing interactions.

Subject of Research: Electrophysiological diagnosis and device management of dual atrial flutter and ventricular tachycardia in Fabry disease

Article Title: Case Report: The mystery of a wide-QRS complex tachycardia with a competitive pacing rhythm: device malfunction?

Article References: Sun, X., Wang, Q., & Wang, L. (2026). Case Report: The mystery of a wide-QRS complex tachycardia with a competitive pacing rhythm: device malfunction?. Frontiers in Cardiovascular Medicine, 13, Article 1967110. https://doi.org/10.3389/fcvm.2026.1967110

Image Credits: AI Generated

DOI: 10.3389/fcvm.2026.1967110

Keywords: Fabry disease, implantable cardioverter-defibrillator, ventricular tachycardia, atrial flutter, competitive pacing rhythm, ventricular rate regulation, wide-QRS complex tachycardia, hypertrophic cardiomyopathy, atrial tachycardia therapy, atrioventricular dissociation, antitachycardia pacing, cardiac electrophysiology, device interrogation, allogeneic kidney transplantation, Boston Scientific, emergency medicine, cardiac pacing

News Source: Ophelia Keating. (November 25, 2026). Device Reprogramming Resolves Dual Arrhythmia and Competitive Pacing in Fabry Disease Case. Scienmag.

Tags: allogeneic kidney transplantationantitachycardia pacingatrial flutteratrial tachycardia therapyatrioventricular dissociationBoston ScientificCardiac Electrophysiologycardiac pacingcompetitive pacing rhythmdevice interrogationemergency medicineFabry diseasehypertrophic cardiomyopathyimplantable cardioverter-defibrillatorventricular rate regulationventricular tachycardiawide-QRS complex tachycardia
Share12Tweet7Share2ShareShareShare1

Related Posts

Adults Benefit From Vagus Nerve Stimulation Regardless of Epilepsy Duration

Adults Benefit From Vagus Nerve Stimulation Regardless of Epilepsy Duration

November 25, 2026
Plant Compounds Target NMDA Receptors to Shield Neurons from Toxic Overstimulation

Plant Compounds Target NMDA Receptors to Shield Neurons from Toxic Overstimulation

November 25, 2026

Pembrolizumab With Chemotherapy Proves Not Cost-Effective in Brazilian Lung Cancer Analysis

November 25, 2026

Local Simvastatin and Rosuvastatin Gels Improve Chronic Periodontitis Outcomes in Clinical Trial

November 25, 2026

POPULAR NEWS

  • Multimodal Retinal Imaging Uncovers Cellular and Molecular Biomarkers of Neurodegenerative Diseases

    Multimodal Retinal Imaging Uncovers Cellular and Molecular Biomarkers of Neurodegenerative Diseases

    29 shares
    Share 12 Tweet 7
  • Review Highlights Critical Priorities for Measuring Lost Productivity in Health Economic Evaluations

    29 shares
    Share 12 Tweet 7
  • Pilot Study Finds Comparable Pain Relief for Disc-FX and L’DISQ

    29 shares
    Share 12 Tweet 7
  • Iterative Three-Way Fuzzy Clustering Enhances Data Partitioning Through Dynamic Membership Distributions

    29 shares
    Share 12 Tweet 7

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

Scientometric Review Tracks Digital Metallurgy Advances Across Decade of Industrial Research

Adults Benefit From Vagus Nerve Stimulation Regardless of Epilepsy Duration

Nickel Decoration Boosts Tungsten Diselenide Energy Storage and Thermoelectric Performance in Simulations

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 89 other subscribers
  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.