• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Tuesday, November 17, 2026
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Health

Cervical Viscoelastic Measurements Establish Reference Ranges Across First and Second Trimesters

by
November 8, 2026
in Health
Reading Time: 2 mins read
0
Cervical Viscoelastic Measurements Establish Reference Ranges Across First and Second Trimesters

Cervical Viscoelastic Measurements Establish Reference Ranges Across First and Second Trimesters

Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

Researchers conducting a prospective cohort study at Nanjing Drum Tower Hospital established reference values for cervical viscoelastic parameters during the first and second trimesters of uncomplicated singleton pregnancies, finding that tissue stiffness and viscosity measurements decreased significantly as gestation advanced. All viscoelastic measurements across both the anterior and posterior cervical lips showed a statistically significant decline between the two trimesters (P < 0.0001), reflecting measurable biomechanical changes during pregnancy.

The prospective cohort trial evaluated pregnant women undergoing prenatal examinations from May 2024 to October 2025. Tissue evaluations were conducted using a Mindray Resona R9 ultrasound system equipped with a 7–9 MHz transvaginal probe, recording measurements at 11–13⁺⁶ weeks of gestation during the first trimester and again at 22–24⁺⁶ weeks of gestation during the second trimester.

Viscoelasticity serves as an indicator for evaluating intrinsic tissue properties, where higher values correspond to stiffer and more viscous tissue. The investigators quantified three specific parameters: shear elastic modulus, viscosity coefficient, and dispersion coefficient. Measurements were mapped anatomically across the internal, middle, and external segments of both the anterior and posterior cervical lips.

The study identified pronounced regional differences throughout the cervix. Within each trimester, viscoelastic values were highest in the internal segment, intermediate in the middle segment, and lowest in the external segment (P < 0.01). Furthermore, corresponding anatomical regions of the posterior cervical lip consistently exhibited higher values than their counterparts in the anterior lip (P < 0.01).

The relationship between cervical length and viscoelasticity varied across gestational stages. Cervical length showed a very weak positive correlation with certain viscoelastic parameters during the first trimester, whereas an inverse, negative correlation emerged between these measures in the second trimester.

All ultrasound viscoelastic measurements demonstrated high reliability, achieving good intra-observer and inter-observer reproducibility with intraclass correlation coefficients exceeding 0.75. The authors concluded that these established reference ranges provide new quantitative tools and baseline data for gestational cervical assessment, noting that their clinical predictive value remains to be determined.

The etiology of preterm birth is complex and multifaceted, involving factors such as preterm cervical softening and remodeling, which poses ongoing challenges for prediction. While ultrasound serves as a convenient and non-invasive tool commonly used to assess the cervix during pregnancy, cervical length measurement has limited accuracy in predicting preterm birth. This limitation highlights an urgent need for more specific indicators to evaluate cervical tissue during gestation.

Researchers used paired statistical tests to evaluate longitudinal changes across gestational time points and examined how these intrinsic viscoelastic parameters related to anatomical cervical length.

Subject of Research: Reference ranges and regional variations of cervical viscoelastic parameters across pregnancy trimesters

Article Title: Reference values of cervical viscoelastic parameters in the first and second trimester of uncomplicated singleton pregnancies: a prospective cohort study

Article References: Ding, Y., Wang, Y., Chen, Y., Liu, M., Dai, C., Yang, L., & Xu, Y. (2026). Reference values of cervical viscoelastic parameters in the first and second trimester of uncomplicated singleton pregnancies: a prospective cohort study. Archives of Gynecology and Obstetrics. https://doi.org/10.1007/s00404-026-08520-1

Image Credits: AI Generated

DOI: 10.1007/s00404-026-08520-1

Keywords: cervical viscoelasticity, pregnancy, ultrasound imaging, first trimester, second trimester, cervical remodeling, shear elastic modulus, prenatal assessment, Reference, values, cervical, viscoelastic

News Source: Ophelia Keating. (November 8, 2026). Cervical Viscoelastic Measurements Establish Reference Ranges Across First and Second Trimesters. Scienmag.

Tags: cervicalcervical remodelingcervical viscoelasticityfirst trimesterPregnancyprenatal assessmentreferencesecond trimestershear elastic modulusultrasound imagingvaluesviscoelastic
Share12Tweet7Share2ShareShareShare1

Related Posts

Staged Surgical Protocol Reconstructs Adolescent Mandible Following Ossifying Fibroma Resection

Staged Surgical Protocol Reconstructs Adolescent Mandible Following Ossifying Fibroma Resection

November 17, 2026
Comorbidities Associated With Lower RSV Humoral and Cellular Immunity in Older Adults

Comorbidities Associated With Lower RSV Humoral and Cellular Immunity in Older Adults

November 17, 2026

Visual Distraction Reduces Quantitative Light Touch Sensitivity in Healthy Adult Hand Testing

November 17, 2026

Herbal Iridoid Extract Relieves Fatty Liver Hemorrhagic Syndrome in Laying Hens

November 17, 2026

POPULAR NEWS

  • Staged Surgical Protocol Reconstructs Adolescent Mandible Following Ossifying Fibroma Resection

    Staged Surgical Protocol Reconstructs Adolescent Mandible Following Ossifying Fibroma Resection

    29 shares
    Share 12 Tweet 7
  • Microglia Study Identifies FKBP5 as a Regulator of Alzheimer’s Inflammation

    29 shares
    Share 12 Tweet 7
  • Holmium Substitution Improves SmFeO3 Supercapacitor Electrochemical Performance in KI/KOH Electrolyte

    29 shares
    Share 12 Tweet 7
  • Comorbidities Associated With Lower RSV Humoral and Cellular Immunity in Older Adults

    29 shares
    Share 12 Tweet 7

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

Staged Surgical Protocol Reconstructs Adolescent Mandible Following Ossifying Fibroma Resection

Microglia Study Identifies FKBP5 as a Regulator of Alzheimer’s Inflammation

Holmium Substitution Improves SmFeO3 Supercapacitor Electrochemical Performance in KI/KOH Electrolyte

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 88 other subscribers
  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.