• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Thursday, August 14, 2025
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Chemistry

‘Aneurysm Number’ may help surgeons make treatment decisions

Bioengineer by Bioengineer
March 26, 2019
in Chemistry
Reading Time: 3 mins read
0
Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

Simple parameter that depends on geometry and flow waveform can classify the flow mode into sidewall or bifurcation aneurysms

IMAGE

Credit: Hafez Asgharzadeh, Hossein Asadi, Hui Meng and Iman Borazjani

WASHINGTON, D.C. March 26, 2019 — Aneurysms form as abnormal bulges or balloonings over an artery, and, if ruptured, can lead to serious health complications or even death. Some aneurysms can exist for a long time without rupturing, and the surgery involved in treating aneurysms can be quite risky, so a parameter to help guide surgeons is needed.

Today, treatment decisions are made mainly by assessing the geometric parameters such as the size of an aneurysm, which is obtained from medical images. But the fluid mechanics are known to be an important factor in the initiation, growth and rupture of aneurysms. The factors determined by flow, such as the shear stress and its oscillations on the walls of an artery, require cumbersome flow measurements and numerical simulations. A simple parameter that depends on both flow and geometry, which can substitute flow factors (that require flow measurements and simulations) doesn’t exist.

But now, as researchers from the University at Buffalo and Texas A&M University report in the journal Physics of Fluids, from AIP Publishing, they have developed a simple nondimensional parameter that depends on both geometry and flow waveform to classify the flow mode in both sidewall and bifurcation aneurysms.

“This simple parameter, called ‘aneurysm number (An),’ is the ratio of time scales of two competing phenomena in aneurysms: First is the transport time scale, which represents the transport of a fluid particle through the aneurysm expansion,” said Iman Borazjani, an associate professor at Texas A&M. “Second is the vortex formation time scale, which represents the formation of a vortex due to the pulsatile flow into an expansion.”

The transport phenomenon creates a stationary shear layer through the expansion region, he explained, whereas the vortex phenomenon likes to create a vortex ring. If the transport time scale is smaller (An1) and the flow mode is the vortex mode.

The group’s work is a significant breakthrough because they were able to show that not only can their aneurysm number classify the flow mode in both simplified and anatomic geometries, but also that the oscillations of shear stress are higher in the flow in the vortex mode (An>1). “This means that our simple parameter might be a good substitute for the oscillatory shear parameter — without the need for challenging flow measurements and simulations to calculate shear on the wall,” Borazjani said.

When the researchers first submitted their simplified work, several reviewers questioned whether the results for simplified geometries are applicable to real anatomic ones. “They weren’t convinced, so we had to show that our parameter works for anatomic geometries. Now, a pair of articles are being published together,” Borazjani said, explaining why the group went on to write a second article about their work. They first developed and tested their parameter for simplified (idealized) geometries in part I of their article, and then applied it to anatomic ones in part II.

Oscillatory shear, which is related to the group’s parameter, is thought to affect the endothelial cells and promote inflammation, growth of aneurysms, and even their rupture. For example, “a vortex flow mode is more likely to rupture because it has a higher oscillatory shear,” Borazjani said. “Therefore, we think our simple parameter can help surgeons in making decisions to treat an aneurysm in the future.”

###

The first part of the article, “A non-dimensional parameter for classification of the flow in intracranial aneurysms I: Simplified geometries,” is authored by Hafez Asgharzadeh and Iman Borazjani. The second part, “A non-dimensional parameter for classification of the flow in intracranial aneurysms II: Patient-specific geometries,” is authored by Hafez Asgharzadeh, Hossein Asadi, Hui Meng and Iman Borazjani. The pair of articles will appear in Physics of Fluids on March 26, 2019 (DOI: 10.1063/1.5033942; DOI: 10.1063/1.5081451). After that date, the articles can be accessed at http://aip.scitation.org/doi/full/10.1063/1.5033942 and http://aip.scitation.org/doi/full/10.1063/1.5081451.

ABOUT THE JOURNAL

Physics of Fluids is devoted to the publication of original theoretical, computational, and experimental contributions to the dynamics of gases, liquids, and complex or multiphase fluids. See http://pof.aip.org.

Media Contact
Wendy Beatty
[email protected]

Related Journal Article

http://dx.doi.org/10.1063/1.5033942

Tags: Biomechanics/BiophysicsCardiologyChemistry/Physics/Materials SciencesMedicine/Health
Share12Tweet7Share2ShareShareShare1

Related Posts

blank

WSU Researchers Uncover Biological Mechanism Behind Coho Salmon Die-Offs

August 14, 2025
Fluorenol Photobases Enable Ambient CO2 Capture

Fluorenol Photobases Enable Ambient CO2 Capture

August 14, 2025

Accelerating Detection of Shadows in Fusion Systems Using AI

August 14, 2025

Introducing 3D-SLISE: A Quasi-Solid Electrolyte Paving the Way for Safer and Greener Lithium-Ion Batteries

August 13, 2025
Please login to join discussion

POPULAR NEWS

  • blank

    Molecules in Focus: Capturing the Timeless Dance of Particles

    140 shares
    Share 56 Tweet 35
  • Neuropsychiatric Risks Linked to COVID-19 Revealed

    79 shares
    Share 32 Tweet 20
  • Modified DASH Diet Reduces Blood Sugar Levels in Adults with Type 2 Diabetes, Clinical Trial Finds

    58 shares
    Share 23 Tweet 15
  • Predicting Colorectal Cancer Using Lifestyle Factors

    47 shares
    Share 19 Tweet 12

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

New Compound Targets Survival Mechanisms in Aromatase Inhibitor-Resistant Breast Cancer Cells

Groundbreaking Discovery Ignites New Hope for Breathing Recovery Following Spinal Cord Injuries

Scientists Return to Fundamentals with Streamlined Plant Genomes

  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.