• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Monday, September 15, 2025
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Chemistry

Sweat, bleach and gym air quality

Bioengineer by Bioengineer
January 5, 2021
in Chemistry
Reading Time: 3 mins read
0
IMAGE
Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

New study shows high bodily emissions during workouts, intensified by chemical reactions with cleaners

IMAGE

Credit: Katie Weeman/CIRES

One sweaty, huffing, exercising person emits as many chemicals from their body as up to five sedentary people, according to a new University of Colorado Boulder study. And notably, those human emissions, including amino acids from sweat or acetone from breath, chemically combine with bleach cleaners to form new airborne chemicals with unknown impacts to indoor air quality.

“Humans are a large source of indoor emissions,” said Zachary Finewax, CIRES research scientist and lead author of the new study out in the current edition of Indoor Air. “And chemicals in indoor air, whether from our bodies or cleaning products, don’t just disappear, they linger and travel around spaces like gyms, reacting with other chemicals.”

In 2018, the CU Boulder team outfitted a weight room in the Dal Ward Athletic Center–a campus facility for university student athletes, from weightlifters to cheerleaders–with a suite of air-sampling equipment. Instruments collected data from both the weight room and supply air, measuring a slew of airborne chemicals in real time before, during and after workouts of CU athletes. The team found the athletes’ bodies produced 3-5 times the emissions while working out, compared to when they were at rest.

“Using our state-of-the-art equipment, this was the first time indoor air analysis in a gym was done with this high level of sophistication. We were able to capture emissions in real time to see exactly how many chemicals the athletes were emitting, and at what rate,” said Demetrios Pagonis, postdoctoral researcher at CIRES and co-author on the new work.

Many gym facilities frequently use chlorine bleach-based products to sanitize sweaty equipment. And while these cleaning products work to kill surface bacteria–they also combine with emissions from sweat–mixing to form a new cocktail of chemicals.

The team was the first to observe a chemical group called N-chloraldimines–a reaction product of bleach with amino acids–in gym air. That meant chlorine from bleach cleaner sprayed onto equipment was reacting with the amino acids released from sweating bodies, the authors report.

And although more research is needed to determine specific impacts this might have on indoor air quality, chemically similar reaction products of ammonia with bleach can be harmful to human health.

“Since people spend about 90 percent of our time indoors, it’s critical we understand how chemicals behave in the spaces we occupy,” said Joost de Gouw, CIRES Fellow, professor of chemistry at CU Boulder and corresponding author on the paper. Although the researchers collected all data for this study pre-pandemic, the team says their results illustrate that a modern gym with low occupancy and good ventilation may still be relatively safe for a workout, especially if masks are used.

###

“Quantification and source characterization of volatile organic compounds from exercising and application of chlorine?based cleaning products in a university athletic center” published in Wiley’s Indoor Air on December 18, 2020. Authors include: Zachary Finewax (CIRES, CU Boulder Chemistry), Demetrios Pagonis (CIRES, CU Boulder Chemistry), Megan S. Claflin (Aerodyne Research), Anne V. Handschy (CIRES, CU Boulder Chemistry), Wyatt L. Brown (CIRES, CU Boulder Chemistry), Olivia Jenks (CIRES, CU Boulder Chemistry), Benjamin A. Nault (CIRES, CU Boulder Chemistry), Douglas A. Day (CIRES, CU Boulder Chemistry), Brian M. Lerner (Aerodyne Research), Jose L. Jimenez (CIRES, CU Boulder Chemistry), Paul J. Ziemann (CIRES, CU Boulder Chemistry), Joost A. de Gouw (CIRES, CU Boulder Chemistry).

The authors gratefully acknowledge the Sloan Foundation for funding the measurements and instrumentation used in this study, and the CU Boulder Dal Ward Athletic Center for the use of their facilities to collect all data for this work.

Media Contact
Kelsey Simpkins
[email protected]

Original Source

https://cires.colorado.edu/news/sweat-bleach-gym-air-quality

Related Journal Article

http://dx.doi.org/10.1111/ina.12781

Tags: BiochemistryChemistry/Physics/Materials SciencesEnvironmental HealthSports/Recreation
Share12Tweet8Share2ShareShareShare2

Related Posts

Breaking Down the Quantum W State: New Insights from Recent Measurements

Breaking Down the Quantum W State: New Insights from Recent Measurements

September 15, 2025
Wiley Enhances Knowitall Solutions with Trendfinder App for Intuitive Chemometric Analysis and Improved Analytical Workflows

Wiley Enhances Knowitall Solutions with Trendfinder App for Intuitive Chemometric Analysis and Improved Analytical Workflows

September 15, 2025

In-Situ Molecular Passivation Boosts Pure-Blue Perovskite LEDs Through Vacuum Thermal Evaporation

September 15, 2025

Researchers Identify Crucial Role of Small Molecules in Stabilizing Biological Systems

September 15, 2025
Please login to join discussion

POPULAR NEWS

  • blank

    Breakthrough in Computer Hardware Advances Solves Complex Optimization Challenges

    154 shares
    Share 62 Tweet 39
  • New Drug Formulation Transforms Intravenous Treatments into Rapid Injections

    116 shares
    Share 46 Tweet 29
  • Physicists Develop Visible Time Crystal for the First Time

    66 shares
    Share 26 Tweet 17
  • A Laser-Free Alternative to LASIK: Exploring New Vision Correction Methods

    49 shares
    Share 20 Tweet 12

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

Inulin Boosts Small Intestine Bacteria’s Fructose Use

Experts Warn Preventable Deaths Will Persist Without Improved NHS Accessibility for Autistic People

Heat-Related Road Deaths Vary Across Latin America

  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.