Analytical chemists have developed and validated an eco-efficient, stability-indicating ultra-performance liquid chromatographic method for the simultaneous determination of avibactam and aztreonam in pharmaceutical formulations. The protocol applies an Analytical Quality by Design approach to establish reliable quantification for both active substances.
To support sustainable analytical development, the investigators applied a solvent selection strategy based on Hansen Solubility Parameter space. This assessment identified ethanol as an effective, green alternative to conventional hazardous organic solvents typically employed in chromatographic systems.
According to the investigators, this procedure represents the first reported stability-indicating ultra-performance liquid chromatographic method for simultaneous determination of avibactam and aztreonam that integrates Hansen Solubility Parameter-guided solvent selection with comprehensive Green, Red, Blue, and White analytical chemistry assessment. During development, critical method parameters underwent systematic optimization to secure reproducible chromatographic resolution and consistent analytical performance.
Separation of the target compounds was executed on a Waters BEH C18 column measuring 2.1 by 50 millimeters with a 3.0-micrometer particle size. The optimized mobile phase consisted of a phosphate buffer adjusted to pH 6.0 combined with ethanol in a 30 to 70 volume-to-volume ratio. The mobile phase traveled through the stationary phase at a steady flow rate of 0.4 milliliters per minute.
Analyte detection was carried out using a photodiode array detector set to an operating wavelength of 225 nanometers. Each analytical cycle utilized a 4-microliter sample injection volume and achieved full chromatographic separation within an eight-minute total run time.
The analytical method underwent rigorous validation in compliance with International Council for Harmonisation guidelines. Validation trials confirmed acceptable specificity, linearity, accuracy, precision, robustness, and sensitivity across testing intervals. Across all evaluated validation parameters, relative standard deviation values remained below two percent, confirming the high precision and operational reliability of the chromatographic procedure.
To evaluate stability-indicating capability, the investigators conducted forced degradation experiments exposing the drug combination to acidic, alkaline, oxidative, thermal, and photolytic stress conditions. Chromatographic results demonstrated that the method effectively resolved all generated degradation products from the parent analyte peaks.
Method sustainability and overall operational performance were systematically evaluated using multiple evaluation tools, including the Green Analytical Procedure Index, AGREE metric, Analytical Method Greenness Score, Carbon Footprint Analysis, Red Analytical Procedure Index, Blue Applicability Grade Index, and White Analytical Chemistry principles. The favorable assessment scores across the complementary red, green, and blue dimensions confirmed an effective balance between environmental sustainability, analytical performance, operational practicality, and method excellence for routine pharmaceutical quality control.
Subject of Research: Eco-efficient stability-indicating chromatographic determination of avibactam and aztreonam
Article Title: Eco-efficient AQbD-based stability-indicating UPLC method development and validation for simultaneous determination of Avibactam and Aztreonam with integrated green, red, blue and white analytical assessment
Article References: Rosireddy, V., Krishnan, M., Siraj, R., & Ismail, Y. (2026). Eco-efficient AQbD-based stability-indicating UPLC method development and validation for simultaneous determination of Avibactam and Aztreonam with integrated green, red, blue and white analytical assessment. BMC Chemistry. https://doi.org/10.1186/s13065-026-01931-w
Image Credits: AI Generated
DOI: 10.1186/s13065-026-01931-w
Keywords: Avibactam, Aztreonam, Ultra-Performance Liquid Chromatography, Analytical Quality by Design, Hansen Solubility Parameters, Green Analytical Chemistry, Stability-Indicating Method, Forced Degradation, Method Validation, Waters BEH C18, Photodiode Array Detection, White Analytical Chemistry, AGREE Metric, GAPI, Carbon Footprint Analysis, Pharmaceutical Formulations
News Source: Bethany Barker. (November 22, 2026). Sustainable Liquid Chromatography Technique Simultaneously Quantifies Avibactam and Aztreonam. Scienmag.



