A retrospective cross-sectional study evaluating 434 adults undergoing thoracic surgery has revealed that selecting double-lumen tube sizes based on patient height and sex resulted in tubes with an outer diameter wider than the measured inner short-axis diameter of the left main bronchus in 59.7 percent of cases. Published in the Journal of Anesthesia, Analgesia and Critical Care, the findings question whether standard selection protocols adequately reflect the individualized airway dimensions of surgical patients.
In clinical thoracic surgery, double-lumen tube size is traditionally chosen according to patient height and sex rather than direct airway imaging. The research team hypothesized that this conventional practice fails to fit every patient appropriately because it does not account for individual anatomical variation. To test this hypothesis, the investigators evaluated whether preoperative computed tomography scans could provide reproducible measurements of the main bronchi when analyzed by non-radiologist physicians.
The study cohort included 223 male and 211 female adult patients who underwent thoracic operations between 2021 and 2023. Using four-view multiplanar reconstruction on computed tomography, the evaluators systematically measured both the short-axis and long-axis inner diameters of the left main bronchus and right main bronchus at a standardized location one centimeter below the carina. In addition, the researchers measured bronchial length extending from the carina to the origin of the upper lobe.
To establish whether the imaging assessment could be performed reliably outside specialized radiology departments, two trained non-radiologist physicians independently performed the bronchial measurements. Reliability testing confirmed strong consistency between the observers, yielding inter-rater intraclass correlation coefficients ranging between 0.827 and 0.959. These results demonstrated that non-radiologists can reproducibly measure main bronchial dimensions using multiplanar computed tomography reconstructions.
Anatomical measurements revealed marked variations in airway caliber between sexes across the cohort. Male patients presented with significantly larger short-axis bronchial diameters than female patients, with left main bronchial inner diameters averaging 11.73 ± 1.54 millimeters in males compared to 9.91 ± 1.47 millimeters in females. Right main bronchial short-axis inner diameters similarly measured larger in males at 12.76 ± 1.68 millimeters compared to 10.78 ± 1.60 millimeters in females.
Multivariable linear regression analysis identified specific patient characteristics independently linked to bronchial dimensions. Greater body height and male sex were both statistically associated with larger short-axis diameters in both the left and right main bronchi. Conversely, patient age demonstrated a non-linear association with bronchial caliber across the investigated surgical population.
When the researchers compared the outer diameter of the double-lumen tube selected by standard height and sex criteria against each patient’s computed tomography-measured left main bronchial short-axis diameter, the selected tube was wider than the airway in 259 of the 434 patients, representing 59.7 percent. The authors concluded that computed tomography measurements may help inform double-lumen tube selection, while emphasizing that actual clinical tube fit was not directly assessed and prospective studies remain necessary.
Subject of Research: Computed tomography measurement of bronchial dimensions for double-lumen tube selection in thoracic surgery
Article Title: Individualized computed tomography measurement of main bronchial dimensions for double-lumen tube selection in adults undergoing thoracic surgery: a retrospective cross-sectional study
Article References: Supphapipat, K., Pipanmekaporn, T., Supphapipat, A., Samerchua, A., Leurcharusmee, P., Prom-in, K., Sunburut, J., Bunchungmongkol, N., & Euathrongchit, J. (2026). Individualized computed tomography measurement of main bronchial dimensions for double-lumen tube selection in adults undergoing thoracic surgery: a retrospective cross-sectional study. Journal of Anesthesia, Analgesia and Critical Care. https://doi.org/10.1186/s44158-026-00482-9
Image Credits: AI Generated
DOI: 10.1186/s44158-026-00482-9
Keywords: thoracic surgery, double-lumen tube, computed tomography, left main bronchus, right main bronchus, multiplanar reconstruction, bronchial diameter, airway anatomy, inter-rater reliability, intraclass correlation coefficient, retrospective cross-sectional study, tube selection, multivariable linear regression, carina, bronchial length, non-radiologist measurements
News Source: Ophelia Keating. (November 17, 2026). Standard Tube Sizing Exceeded Left Bronchial Width in Most Thoracic Patients. Scienmag.