• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Tuesday, November 24, 2026
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Health

Pretreatment MRI Diffusion Outperforms Photon-Counting Iodine Imaging in Rectal Cancer Study

by
November 23, 2026
in Health
Reading Time: 6 mins read
0
Pretreatment MRI Diffusion Outperforms Photon-Counting Iodine Imaging in Rectal Cancer Study

Pretreatment MRI Diffusion Outperforms Photon-Counting Iodine Imaging in Rectal Cancer Study

Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

A retrospective diagnostic investigation in rectal adenocarcinoma has demonstrated that magnetic resonance imaging-derived apparent diffusion coefficient measurements distinguish histopathologic treatment response, whereas normalized iodine concentration from portal-venous photon-counting computed tomography failed to differentiate response categories. Across an expanded cohort of sixty-three patients undergoing neoadjuvant therapy followed by surgical resection, tumors showing poor histopathologic response exhibited significantly lower mean pretreatment apparent diffusion coefficient values compared to tumors achieving moderate or complete regression. The study indicated that while diffusion-weighted magnetic resonance imaging provides a moderately predictive reference marker of tumor cellularity, single-phase portal-venous spectral computed tomography using two-dimensional region-of-interest measurements offers no incremental predictive value when added to diffusion assessments.

Patients were required to have completed pretreatment pelvic magnetic resonance imaging with interpretable diffusion-weighted sequences alongside contrast-enhanced photon-counting computed tomography with adequate iodine maps prior to neoadjuvant treatment and surgery. Within this cohort, forty-one patients achieved moderate to good histopathologic regression classified under Dworak tumor regression grades two through four, while twenty-two patients demonstrated poor regression categorized as Dworak grades zero or one. The mean patient age at computed tomography was 65.1 ± 12.6 years, comprising thirty-seven male and twenty-six female patients. Mucinous adenocarcinomas and non-adenocarcinoma histologic subtypes were excluded because extracellular mucin distorts apparent diffusion coefficient quantification. Synchronous metastatic disease was permitted, and twenty-one of sixty-three patients overlapped with a prior pilot cohort, establishing this investigation as an expanded reassessment rather than an independent external validation.

Diagnostic evaluations followed tight clinical scheduling, with pelvic magnetic resonance imaging and photon-counting computed tomography conducted a median of three days apart, spanning an interquartile range of one to 4.5 days. Fifty-three patients completed both modalities within seven days, and fifty-nine completed both evaluations within thirty days prior to initiating neoadjuvant therapy. Mesorectal fascia status was defined as threatened or involved when the minimum distance between tumor and fascia was less than or equal to one millimeter, and clear when exceeding one millimeter or explicitly uninvolved.

All contrast-enhanced spectral computed tomography scans were performed on a dual-source photon-counting computed tomography system using vendor-specific acquisition architecture with automatic tube-current modulation set at an image-quality level of 170 and a tube potential of 120 kilovolts peak. Acquisition parameters included a collimation width of 144 × 0.4 millimeters, pitch of 0.8, and rotation time of 0.5 seconds. Contrast administration utilized accupaque 300 iodinated contrast medium at a dosage of one milliliter per kilogram of body weight injected at 2.4 milliliters per second, followed by a forty-milliliter saline chaser. Imaging was initiated via bolus tracking in the descending aorta, commencing scanning sixty seconds after reaching a threshold of one hundred Hounsfield units to capture portal-venous enhancement. Spectral images were reconstructed using a dedicated quantitative kernel, iterative reconstruction strength four, slice thickness of 0.6 millimeters with a 0.4-millimeter increment, and a 512 × 512 matrix.

Pretreatment magnetic resonance examinations were conducted on clinical 1.5-Tesla scanners, utilizing a Magnetom Sola system in thirty-six patients or a Magnetom Avanto Fit system in twenty-seven patients with phased-array body coils. Standardized imaging included high-resolution tumor-adapted axial T2-weighted turbo spin-echo sequences featuring repetition time of 4060 milliseconds, echo time of 68 milliseconds, slice thickness of three millimeters without gap, and 240-millimeter field of view. Diffusion-weighted imaging utilized acquired b-values of 50 and 1000 seconds per square millimeter, alongside a computed b-value of 800 seconds per square millimeter, consistent with European Society of Gastrointestinal and Abdominal Radiology guidelines. Repetition and echo times for diffusion sequences were approximately 3700 and 87 milliseconds on Sola and 4700 and 86 milliseconds on Avanto Fit. Hyoscine butylbromide was routinely administered before pelvic imaging to suppress peristalsis, and apparent diffusion coefficient maps were generated automatically by scanner software.

Quantitative imaging analysis involved independent measurements by two certified radiologists with six and twenty years of experience who were blinded to histopathologic outcomes. Apparent diffusion coefficient values were obtained by placing a single freehand two-dimensional region of interest on the axial slice displaying the largest cross-sectional tumor area, maximizing coverage while excluding peripheral margins, intraluminal contents, necrosis, hemorrhage, and partial-volume artifacts. For photon-counting computed tomography, iodine maps were evaluated using syngo.via software, where a single polygonal two-dimensional region of interest was placed over enhancing solid tumor on the axial slice showing largest cross-section. A second region of interest was placed in the abdominal aorta on the same dataset to calculate normalized iodine concentration, defined as tumor iodine divided by aortic iodine concentration. Absolute iodine concentrations were measured directly on vendor-generated material decomposition maps in milligrams per cubic centimeter without monoenergetic conversions, and regions of interest were selected independently without spatial co-registration.

Histopathologic evaluation of surgical resection specimens served as the study reference standard. Tumor regression was classified using the five-tier Dworak grading system, wherein grade zero corresponds to absent regression, grade one indicates predominantly viable tumor, grade two represents predominantly fibrosis with residual tumor, grade three denotes isolated residual tumor cells, and grade four signifies complete regression without viable malignant cells. In the sixty-three-patient analytic cohort, individual distributions showed grade zero in two patients, grade one in twenty, grade two in twenty-two, grade three in ten, and grade four in nine. Histopathologic assessment was performed on hematoxylin-eosin sections at forty-times and two-hundred-times magnification by a board-certified pathologist with twenty years of experience blinded to quantitative imaging metrics. The ordinal regression tiers were dichotomized into poor responders, comprising twenty-two patients with grades zero and one, and moderate-to-good responders, comprising forty-one patients with grades two through four.

Observer reproducibility was evaluated to ensure measurement stability across reading radiologists. Interobserver agreement for apparent diffusion coefficient measurements across all sixty-three patients was excellent, exhibiting a two-way random-effects absolute-agreement single-measurement intraclass correlation coefficient of 0.959 with a ninety-five percent confidence interval of 0.90 to 0.98. Bland-Altman agreement analysis revealed a mean difference between the second and first reader of -0.029 × 10⁻³ square millimeters per second, with limits of agreement extending from -0.132 to 0.073 × 10⁻³ square millimeters per second. Interobserver reproducibility for normalized iodine concentration was evaluated in sixty-one patients possessing complete paired numerical readings, as two patients lacked second-observer values due to documented technical limitations. Normalized iodine concentration also demonstrated excellent interobserver agreement, yielding an intraclass correlation coefficient of 0.905 with a bootstrap ninety-five percent confidence interval of 0.858 to 0.936, a mean interobserver bias of 0.017, and limits of agreement from -0.083 to 0.117.

Comparative analysis of baseline imaging metrics identified clear statistical differences in water diffusivity between histopathologic response groups. Mean pretreatment apparent diffusion coefficient values were significantly lower among patients demonstrating poor response than among those achieving moderate or good tumor regression, measuring 0.876 ± 0.186 × 10⁻³ square millimeters per second versus 1.035 ± 0.208 × 10⁻³ square millimeters per second. This difference represented a statistically significant mean decrement of -0.159 × 10⁻³ square millimeters per second with a ninety-five percent confidence interval of -0.262 to -0.056 and a Welch t-test p-value of 0.003. Median values were 0.852 × 10⁻³ square millimeters per second in poor responders and 1.044 × 10⁻³ square millimeters per second in moderate-to-good responders. Receiver operating characteristic analysis showed moderate apparent diagnostic discrimination for apparent diffusion coefficient in identifying poor response, with an area under the curve of 0.738. Biologically, restricted water diffusivity in poor responders reflects dense cellularity, reduced extracellular volume, intact cellular membranes, and compact tissue architecture.

In contrast to diffusion imaging, portal-venous normalized iodine concentration showed no capacity to differentiate tumor response categories. Median normalized iodine concentration was 0.313 in poor responders compared to 0.370 in moderate-to-good responders, yielding a non-significant Mann-Whitney U test p-value of 0.91 and an area under the receiver operating characteristic curve of 0.509 with a confidence interval of 0.362 to 0.656. Applying the previously published threshold of 0.36 or greater without re-optimization yielded sensitivity of 53.7 percent, specificity of 63.6 percent, positive predictive value of 73.3 percent, negative predictive value of 42.4 percent, and overall accuracy of 57.1 percent. Paired DeLong analysis confirmed that apparent diffusion coefficient significantly outperformed normalized iodine concentration, with an area under the curve difference of 0.228 and a p-value of 0.041. In binary logistic regression modeling, apparent diffusion coefficient remained associated with poor response with an odds ratio of 0.646 per 0.1-unit increase, whereas normalized iodine concentration was not associated with response, showing an odds ratio of 0.884 and p-value of 0.602, while a likelihood-ratio test confirmed no improvement in model fit.

The authors noted several important limitations inherent to their single-center retrospective study design. The cohort size was constrained by twenty-two poor-response events, which restricted statistical power and precluded comprehensive multivariable adjustment for clinical confounders. Furthermore, because twenty-one patients overlapped with the previously published thirty-five-patient pilot cohort, this study represented an expanded reassessment rather than an independent external validation. The negative predictive findings regarding normalized iodine concentration were specifically obtained from single-phase portal-venous acquisitions using two-dimensional region-of-interest sampling, which cannot capture dynamic perfusion kinetics, whole-tumor heterogeneity, or arterial-phase vascular delivery, meaning results should not be generalized to multiphasic or volumetric spectral computed tomography techniques. Additionally, exact patient-level data underlying the primary analysis could not be reconstructed to perform reproducible bootstrap optimism correction, and proprietary scanner software fitting algorithms for apparent diffusion coefficient calculation were not retrospectively recoverable.

Subject of Research: Pretreatment MRI and photon-counting CT biomarkers for rectal cancer treatment response

Article Title: Photon-counting computed tomography and magnetic resonance imaging in rectal cancer: reassessment of normalized iodine concentration and apparent diffusion coefficient in an expanded cohort

Article References: Saeed, S., Shahzadi, I., Niehoff, J. H., Schreck, J., Katz, M. S., Miller, M., Moenninghoff, C., Kroeger, J. R., Borggrefe, J., & Surov, A. (2026). Photon-counting computed tomography and magnetic resonance imaging in rectal cancer: reassessment of normalized iodine concentration and apparent diffusion coefficient in an expanded cohort. Abdominal Radiology. https://doi.org/10.1007/s00261-026-05831-4

Image Credits: AI Generated

DOI: 10.1007/s00261-026-05831-4

Keywords: rectal adenocarcinoma, apparent diffusion coefficient, photon-counting computed tomography, normalized iodine concentration, neoadjuvant therapy, Dworak tumor regression grade, diffusion-weighted imaging, pelvic magnetic resonance imaging, interobserver agreement, receiver operating characteristic, area under the curve, dual-source PCCT, spectral material decomposition, histopathologic response, iodine material maps, b-value imaging, syngo.via

News Source: Nathaniel Bowman. (November 23, 2026). Pretreatment MRI Diffusion Outperforms Photon-Counting Iodine Imaging in Rectal Cancer Study. Scienmag.

Tags: apparent diffusion coefficientarea under the curveb-value imagingdiffusion-weighted imagingdual-source PCCTDworak tumor regression gradehistopathologic responseinterobserver agreementiodine material mapsneoadjuvant therapynormalized iodine concentrationpelvic magnetic resonance imagingphoton-counting computed tomographyreceiver operating characteristicrectal adenocarcinomaspectral material decompositionsyngo.via
Share12Tweet7Share2ShareShareShare1

Related Posts

HIV Study Finds Drug Resistance Mutations in Fourteen Percent of Peruvian Infants

HIV Study Finds Drug Resistance Mutations in Fourteen Percent of Peruvian Infants

November 24, 2026
Structured Martial Arts Warm-Up Improves Knee Alignment and Increases Jump Height

Structured Martial Arts Warm-Up Improves Knee Alignment and Increases Jump Height

November 23, 2026

Lower Social Support Linked to Peripartum Depression in South African Study

November 23, 2026

Simulated High Altitude Care Quality Unchanged Among Unacclimatised Emergency Physicians

November 23, 2026

POPULAR NEWS

  • Thoracic Paraganglioma Diagnosed Posthumously in Patient With Drug-Resistant Pulmonary Tuberculosis

    Thoracic Paraganglioma Diagnosed Posthumously in Patient With Drug-Resistant Pulmonary Tuberculosis

    29 shares
    Share 12 Tweet 7
  • Survey Across Thirty-Two Nations Finds Major Disparities in Coma Care Protocols

    29 shares
    Share 12 Tweet 7
  • Plastic Waste Reaching Deep Ocean Depths Endangers Marine Organisms Relying on Bioluminescence

    29 shares
    Share 12 Tweet 7
  • Case Reports Reveal Distinct Clinical Variants of Anti-GAD Positive Stiff-Person Syndrome

    29 shares
    Share 12 Tweet 7

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

HIV Study Finds Drug Resistance Mutations in Fourteen Percent of Peruvian Infants

Structured Martial Arts Warm-Up Improves Knee Alignment and Increases Jump Height

Secure Framework Cuts Computation and Communication Bottlenecks in Edge Transformer Inference

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 89 other subscribers
  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.