• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Friday, April 3, 2026
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News

New approach uses ultrasound to measure fluid in the lungs

Bioengineer by Bioengineer
March 21, 2017
in Science News
Reading Time: 3 mins read
0
Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

A team of engineering and medical researchers has found a way to use ultrasound to monitor fluid levels in the lung, offering a noninvasive way to track progress in treating pulmonary edema – fluid in the lungs – which often occurs in patients with congestive heart failure. The approach, which has been demonstrated in rats, also holds promise for diagnosing scarring, or fibrosis, in the lung.

"Historically, it has been difficult to use ultrasound to collect quantitative information on the lung, because ultrasound waves don't travel through air- and the lung is full of air," says Marie Muller, an assistant professor of mechanical engineering at North Carolina State University and co-author of a paper on the work. "However, we've been able to use the reflective nature of air pockets in the lung to calculate the amount of fluid in the lung."

When ultrasound waves travel through the body, most of each wave's energy passes through the tissue. But some of that energy is reflected as an echo. By monitoring these echoes, an ultrasound scanner is able to create an image of the tissue that the waves passed through. All of this happens in microseconds.

But when ultrasound waves hit air, all of the energy is reflected – which is why ultrasound images of the lung tend to look like a big, grey blob, with little useful information for health-care providers. And while there are some techniques that allow users to determine if a patient has pulmonary edema, those techniques still can't tell how much fluid there is.

This is where Muller's team comes in.

When ultrasound waves hit air pockets in the lung, or alveoli, they scatter. Those scattered waves hit other air pockets, scattering them further. This process of bouncing around means that it takes an ultrasound's echo much longer to bounce back to the ultrasound machine – though it's still measured in microseconds. And that is why the lung looks like a grey blob to the ultrasound scanner.

But no two ultrasound waves take the same path – they may bounce in different directions as they travel through the lung. So their echoes take different amounts of time to return to the scanner. By looking at all of the echoes, and how those echoes change over time, Muller and her collaborators were able to calculate the extent to which the space between the air pockets was filled with fluid.

To test their approach, the researchers conducted two sets of experiments using rats and rat lung tissue.

In the first set of experiments, researchers used rat lung tissue that had been injected with saline solution to mimic fluid-filled lung tissue. The new approach allowed researchers to quantify the amount of fluid in the lung to within one milliliter.

In the second set of experiments, researchers found significant differences between fluid-filled and healthy lungs in rats. Specifically, the researchers were calculating the mean distance between two "scattering events" – or how far an ultrasound wave traveled between two air pockets.

For fluid-filled lungs, the mean distance was 1,040 micrometers, whereas the mean distance in healthy lungs was only 332 micrometers.

"This is important, because one could potentially track this mean distance value as a way of determining how well pulmonary edema treatment is working," Muller says.

The technique makes use of conventional ultrasound scanning equipment, though the algorithm used by the researchers would need to be incorporated into the ultrasound software.

"Altogether, the cost would likely be comparable to existing ultrasound monitoring applications," Muller says.

The researchers are currently developing two trials: a clinical study in humans and one in a veterinary clinic.

###

The paper, "Characterization of the lung parenchyma using ultrasound multiple scattering," is published in the journal Ultrasound in Medicine & Biology. Lead author of the paper is Kaustav Mohanty, a Ph.D. student at NC State. The paper was co-authored by John Blackwell and Dr. Thomas Egan of the University of North Carolina at Chapel Hill's Department of Surgery.

Media Contact

Matt Shipman
[email protected]
919-515-6386
@NCStateNews

Why Not Us?

############

Story Source: Materials provided by Scienmag

Share12Tweet8Share2ShareShareShare2

Related Posts

Four New Hydroxyl Fatty Acids Discovered in Shrimp

April 3, 2026
blank

Seed Dormancy Influences Gene Drive in Plants

April 3, 2026

Quasi-BIC Metasurfaces Boost Rapid Localized Singlet-Oxygen

April 3, 2026

Linking Older Adults’ Frailty Perceptions to E-Frailty

April 3, 2026
Please login to join discussion

POPULAR NEWS

  • blank

    Revolutionary AI Model Enhances Precision in Detecting Food Contamination

    96 shares
    Share 38 Tweet 24
  • Imagine a Social Media Feed That Challenges Your Views Instead of Reinforcing Them

    1007 shares
    Share 398 Tweet 249
  • Promising Outcomes from First Clinical Trials of Gene Regulation in Epilepsy

    51 shares
    Share 20 Tweet 13
  • Popular Anti-Aging Compound Linked to Damage in Corpus Callosum, Study Finds

    44 shares
    Share 18 Tweet 11

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

Four New Hydroxyl Fatty Acids Discovered in Shrimp

Seed Dormancy Influences Gene Drive in Plants

Quasi-BIC Metasurfaces Boost Rapid Localized Singlet-Oxygen

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 78 other subscribers
  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.