Measuring the mechanical vibrations of structural components during operational rotation provides critical diagnostic insight into their dynamic characteristics, including resonance frequencies, vibration modes, and quality factors. Noncontact measurement techniques based on laser Doppler vibrometry allow investigators to study these vibrating structures without altering their physical properties through added sensor mass or mechanical damping. In laboratory and industrial practice, vibration monitoring of rotating machinery has traditionally relied on two primary optical tracking configurations or on simpler stationary laser beams. Optical tracking systems often incorporate a derotator device equipped with a rotating Dove prism, which turns the optical image by three hundred and sixty degrees for every half revolution around its axis. When this prism is driven at exactly half the rotation rate of the target object, the image appears stationary to the laser vibrometer, enabling continuous observation of a single measurement point across complete operational cycles, provided that an external communication channel continuously supplies instantaneous rotational velocity data.
A second established tracking configuration pairs the laser Doppler vibrometer with a synchronized video camera and real-time image processing algorithms operating through a shared system of optical mirrors. In these camera-assisted assemblies, optical reflections pass simultaneously into the imaging sensor and vibrometer detector while an automated routine continuously tracks a designated target marker located on the rotating surface. The real-time tracking algorithm evaluates the instantaneous spatial offset between the surface target and the incident laser beam, transmitting feedback signals to steering mirrors that dynamically redirect the optical beam to maintain locked tracking on the rotating measurement spot. By sequentially redirecting the tracked location across a predefined grid of surface points, tracking systems of both the derotator and camera-steered classes make it possible to map complex operational deflection shapes across revolving surfaces. Despite their capability to reconstruct complete mode shapes, optical tracking instruments entail substantial financial expense, demand delicate and labor-intensive optical alignment, and require unobstructed line-of-sight access along the entire rotational trajectory of the rotating assembly.
When rotating components such as turbine disks, enclosed screws, or ducted propeller blades operate behind protective shrouds, housings, or mechanical guides, continuous optical tracking becomes physically impossible because the surrounding casing periodically obstructs the beam path. Under these practical constraints, engineers employ fixed-beam laser vibrometry, directing a stationary laser through an available viewing aperture so that the rotating blades pass intermittently through the fixed beam. While fixed-beam architectures eliminate the complexity, maintenance overhead, and high capital costs associated with active mirror tracking systems, they introduce a fundamental signal processing challenge directly tied to the kinematics of rotation. As a moving blade crosses the stationary laser line, the sensor records a sequence of short time-domain pulses characterized by a high duty cycle, where the effective sampling duration during each transit is governed strictly by the physical width of the blade and its linear velocity at the interrogation radius.
Processing these short time-domain pulse sequences with conventional Fourier transform algorithms creates severe diagnostic ambiguities because repeating pulse trains generate extensive false discrete components across periodic spectra. To prevent the multiplication of artificial harmonics, analysts typically isolate and process a single pulse corresponding to an individual blade transit. However, isolating an individual transit pulse exposes the measurement to the classical Fourier resolution limit, where frequency resolution is inversely proportional to observation duration. As the rotational rate of the body increases, the transit time across the optical beam contracts proportionally, causing spectral peaks to broaden. When rotational speeds become sufficiently high, closely spaced discrete vibration peaks merge into a single broad spectral envelope, preventing standard Fourier algorithms from resolving neighboring resonance frequencies that correspond to distinct structural modes.
To overcome this operational limit, researchers V. V. Artelnyi, A. A. Rodionov, and A. V. Stulenkov developed and demonstrated an alternative parameter estimation technique based on the least squares method. Rather than relying on nonparametric Fourier transforms, the approach formulates a parametric mathematical model that explicitly represents the recorded time-domain signal as the sum of a useful deterministic component and zero-mean Gaussian white noise. The deterministic signal model incorporates K complex sinusoids defined by unknown complex amplitudes and unknown frequency parameters sampled across discrete time points. By formulating the deterministic component in a compact matrix representation involving a basis matrix of complex exponential terms multiplied by an unknown complex amplitude vector, the authors framed the identification problem as the minimization of a squared error objective function comparing modeled and measured discrete time vectors.
Because the objective function depends quadratically on the complex amplitude terms, the extremum condition obtained by differentiating with respect to the complex amplitude vector yields an exact, closed-form linear least squares solution for any assumed set of frequencies. Substituting this analytical amplitude solution back into the original error metric produces a concentrated scalar objective function that depends exclusively on the unknown frequency vector and requires maximization. For the specific problem of identifying two closely spaced sinusoids, the resulting objective function exhibits a highly nonlinear topology featuring multiple local extrema. Because analytical derivatives cannot reliably isolate the true optimum amid these local maxima, the researchers utilized an exhaustive grid search across the two-dimensional frequency parameter space, subsequently substituting the identified optimal frequency coordinates back into the linear amplitude equation to recover the corresponding complex amplitudes.
The efficacy of this least squares parameter formulation was validated experimentally using a rotating steel plate mounted in a machine tool to simulate propeller blade behavior under controlled rotational conditions. Prior baseline measurements performed while the plate remained stationary established the benchmark bending vibration frequencies at 91.3 and 110.8 Hz. When the plate was rotated at 10 and 22 rpm, single-pulse Fourier spectra retained distinct, identifiable maxima near these bending modes. However, when the rotational rate was elevated to 55 rpm, the observation window for a single blade passage contracted to a duration of 0.0536 s, setting the classical Fourier resolution limit to 18.7 Hz and causing the two bending peaks to merge completely into an unresolved spectral band. Applying the least squares method to an isolated 55 rpm pulse prefiltered between 70 and 140 Hz successfully separated the modes, yielding estimated frequencies of 91.7 and 110.8 Hz that matched the stationary baseline.
Experimental evaluation also revealed that individual pulses can suffer significant distortion from transient noise or localized scattering anomalies, producing broadened objective function maxima that yield inaccurate frequency estimates such as 104 and 114.8 Hz. To prevent such distorted pulses from degrading measurement reliability, the authors evaluated an averaging strategy applied across multiple consecutive transit events recorded during an 80 s acquisition period that captured 150 pulse passages. By sorting the extracted frequency pairs from each pulse in ascending order and independently averaging the lower and higher frequency estimates across increasing pulse counts, the estimation errors decreased monotonically. At the maximum sample size of 150 pulses, the averaged estimates converged to 91.4 and 110.8 Hz, demonstrating that simple parameter averaging across repeated passages effectively suppresses isolated transit errors without requiring active beam-steering hardware.
To investigate the operational limits of fixed-beam vibrometry at rotational velocities far exceeding 55 rpm, the investigators performed numerical simulations assessing incoherent averaging of the objective function itself prior to peak detection. Simulating synthetic pulses containing 91.4 and 111 Hz sinusoidal components with complex amplitudes derived from experimental fits, the authors introduced random Gaussian amplitude scaling and phase shifts to model pulse-to-pulse incoherence alongside additive Gaussian white noise. Applying the Neumann-Pearson detection strategy, detection and resolution thresholds were determined from false alarm probabilities to evaluate the probability of resolving both discrete components across varying signal-to-noise ratios. Testing pulse durations of 0.055 and 0.01375 s demonstrated that accumulating objective functions across increasing numbers of pulses substantially lowered the signal-to-noise ratio required to achieve robust modal resolution.
The numerical and experimental findings confirm that applying least squares parametric modeling in combination with multi-pulse averaging overcomes the conventional trade-off between rotational velocity and spectral resolution in fixed-beam laser Doppler vibrometry. By replacing unconstrained Fourier analysis with an explicit two-component sinusoidal signal model, the methodology reliably resolves closely spaced structural resonances even when transit durations fall below the threshold required for classical spectral separation. The mathematical formulation provides an affordable and robust diagnostic route for monitoring high-speed rotating blades in enclosed machinery, demonstrating that multi-pulse averaging algorithms can extract high-precision resonance data from intermittent optical signals without introducing expensive optical derotators or complex real-time camera tracking systems.
Subject of Research: Signal processing method for laser Doppler vibrometry of rotating structures
Article Title: Increasing the Frequency Resolution when Measuring Vibrations of Rotating Bodies with Fixed Beam Laser Vibrometry
Article References: Artelnyi, V. V., Rodionov, A. A., & Stulenkov, A. V. (2023). Increasing the Frequency Resolution when Measuring Vibrations of Rotating Bodies with Fixed Beam Laser Vibrometry. Acoustical Physics, 69(3), 367-371. https://doi.org/10.1134/s1063771022700038
Image Credits: AI Generated
DOI: 10.1134/S1063771022700038
Keywords: laser Doppler vibrometry, frequency resolution, rotating bodies, least squares method, vibration measurement, Fourier transform, spectral analysis, discrete components, bending vibrations, incoherent averaging, fixed beam vibrometer, signal to noise ratio, Dove prism, propeller vibration, objective function, parameter estimation, Neumann-Pearson strategy
News Source: Denise Maddox. (November 25, 2026). Least Squares Method Resolves Overlapping Vibration Frequencies in Rapidly Rotating Bodies. Scienmag.