• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Wednesday, August 27, 2025
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Biology

Innovative endoscopic imaging system can detect multiple fluorescent tracers

Bioengineer by Bioengineer
May 26, 2023
in Biology
Reading Time: 3 mins read
0
Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

For patients with solid cancers, endoscopic surgery is one of the primary treatment options to remove tumors. However, there is a high risk of cancer recurrence if even a small number of cancerous cells are left behind after surgical resection. To prevent this from happening, researchers developed fluorescence-guided surgery (FGS). In FGS, patients are injected with a fluorescent probe that preferentially binds to tumor cells, enabling surgeons to easily identify lesions with the help of specialized endoscopes that emit the necessary excitation light.

Bioinspired sensor for the endoscopic imaging system includes a pixel array that can capture light on six different spectral channels.

Credit: George et al., doi 10.1117/1.JBO.28.5.056002.

For patients with solid cancers, endoscopic surgery is one of the primary treatment options to remove tumors. However, there is a high risk of cancer recurrence if even a small number of cancerous cells are left behind after surgical resection. To prevent this from happening, researchers developed fluorescence-guided surgery (FGS). In FGS, patients are injected with a fluorescent probe that preferentially binds to tumor cells, enabling surgeons to easily identify lesions with the help of specialized endoscopes that emit the necessary excitation light.

Unfortunately, tumors can be highly heterogeneous, and a single fluorescent probe is not enough to detect them all. Thus, one of the frontiers in FGS is using cocktails of multiple fluorescent probes (a.k.a. “tracers”) to detect a wider range of tumors, as well as to reduce false positives and negatives. Despite some progress in this direction, clinically approved endoscopes are all optimized to detect only a single tracer. Moreover, multi-tracer instruments currently under development are bulky because they require multiple imaging sensors and optical components.

In a study recently published in Journal of Biomedical Optics (JBO), a research team from University of Illinois Urbana–Champaign reported a novel endoscopic imaging system whose design could greatly accelerate the adoption of multi-tracer FGS.

At the heart of this design lies an innovative hexa-chromatic bioinspired imaging sensor (BIS), which the researchers modeled based on the visual system of the mantis shrimp. The sensor consists of three layers of vertically stacked photodetectors covered with a checkerboard-like arrangement of two different filters; one filters visible light and the other filters near-infrared (NIR) light.

The result is a single-chip camera that can effectively capture light on six different spectral channels, thereby making it capable of detecting even the most subtle differences in fluorescence emission from the tissue being imaged. To put its performance into perspective, this BIS can differentiate fluorescent tracers with emission peaks that are just 20 nanometers (nm) apart. Such a feat is not possible with current clinically approved imaging instruments.      

To be able to use the BIS effectively, the researchers also had to design an appropriate excitation light source for activating the fluorescent tracers. To this end, they used custom bifurcated optical fibers connected to three independent light sources—a white LED and two NIR lasers at 665 and 785 nm. The researchers coupled the combined output of the fibers at the start of the rigid endoscope. In this way, by using a single imaging sensor and a single light input, they made the device less bulky than other multi-tracer imaging systems.

The researchers conducted characterization and benchmarking tests to determine the spatial resolution and sensitivity of the device. In addition, they performed in vivo experiments on a mouse model for breast cancer. These mice were injected with a 680-nm tracer, an 800-nm tracer, or an equal mixture of the two. The proposed system could clearly differentiate between the fluorescence signatures produced by the individual tracers and the mixture.

Aiming to showcase the clinical potential of their endoscope, the researchers used it to image lung cancer nodules that had been just removed from patients. Although these patients had only been injected with one fluorescent tracer, the proposed device was still capable of accurately distinguishing malignant nodules from healthy tissue.

Overall, the researchers achieved important engineering breakthroughs that will pave the way to the adoption of multi-tracer FGS. Thanks to its higher spatial resolution and its remarkable capacity to detect small variations in fluorescence emission, the proposed endoscopic imaging system will help doctors detect smaller or otherwise hidden tumors more easily.

With any luck, this will improve the long-term survival of patients with operable cancer.

Read the Gold Open Access article by M. B. George et al., “Bioinspired color-near infrared endoscopic imaging system for molecular guided cancer surgery,” J. Biomed. Opt. 28(5), 056002 (2023), doi 10.1117/1.JBO.28.5.056002.



Journal

Journal of Biomedical Optics

DOI

10.1117/1.JBO.28.5.056002

Article Title

Bioinspired color-near infrared endoscopic imaging system for molecular guided cancer surgery

Article Publication Date

26-May-2023

Share12Tweet8Share2ShareShareShare2

Related Posts

blank

New Mitochondrial Genome Unveils Monodactylus sebae Insights

August 27, 2025
Identifying Genes Linked to Fat Traits in Xiang Pigs

Identifying Genes Linked to Fat Traits in Xiang Pigs

August 27, 2025

CircCOG5 Regulates Ferroptosis in Ovarian Cancer

August 27, 2025

Heat Stress Impact on Aged Hens’ Health and Performance

August 27, 2025

POPULAR NEWS

  • blank

    Breakthrough in Computer Hardware Advances Solves Complex Optimization Challenges

    148 shares
    Share 59 Tweet 37
  • Molecules in Focus: Capturing the Timeless Dance of Particles

    142 shares
    Share 57 Tweet 36
  • New Drug Formulation Transforms Intravenous Treatments into Rapid Injections

    115 shares
    Share 46 Tweet 29
  • Neuropsychiatric Risks Linked to COVID-19 Revealed

    81 shares
    Share 32 Tweet 20

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

Examining Occupational Gaps and Cognitive Decline in Seniors

OLED-Driven Metasurfaces Enable Holographic Projections

Understanding Female-to-Female Aggression in Workspaces

  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.