• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Friday, October 10, 2025
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Chemistry

How cruise ships can steer clear of viral spread

Bioengineer by Bioengineer
October 31, 2023
in Chemistry
Reading Time: 3 mins read
0
Snapshots of the droplets and flow field at various instances
Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

WASHINGTON, Oct. 31, 2023 – When C-19 began to spread across the globe, its effects were significantly pronounced on cruise ships. Indeed, compared to other population segments, cruise ship passengers became disproportionately infected and often, ironically, stranded on board to quarantine. That’s why focus has been directed at addressing the need for improved ventilation on cruise ships since dispersing fresh air in cabins and other enclosed spaces is critical for mitigating viral spread.

Snapshots of the droplets and flow field at various instances

Credit: Dimitris Drikakis

WASHINGTON, Oct. 31, 2023 – When C-19 began to spread across the globe, its effects were significantly pronounced on cruise ships. Indeed, compared to other population segments, cruise ship passengers became disproportionately infected and often, ironically, stranded on board to quarantine. That’s why focus has been directed at addressing the need for improved ventilation on cruise ships since dispersing fresh air in cabins and other enclosed spaces is critical for mitigating viral spread.

In Physics of Fluids, by AIP Publishing, a group of researchers from Cyprus examined how ventilation can affect transmission of airborne viruses in a typical cruise ship cabin based on guidelines developed before and after the pandemic.

“The most recent standards and regulations on room safety regarding the airborne transmission of viruses focus on high rates of air exchange,” said author Dimitris Drikakis. “But this can be inefficient in terms of energy consumption, can compromise passenger comfort as it generates strong air drafts, and most importantly, can spread saliva droplets up to five times more when passengers cough.”

Drikakis and his team conducted simulations for virus droplets from a cough in a typical cruiser cabin that accommodates two or more people, with different ventilation rates and different positions of the person emitting the cough. Computational fluid dynamics testing ranged from 1.5 to 15 air changes per hour (ACH) to capture all possible scenarios, from minimal ventilation to rates exceeding the most recent recommendations. 

“The study reveals that a higher ventilation rate is not the best strategy to avoid spreading airborne diseases,” Drikakis said. “Complete evaporation of the saliva droplets may not necessarily mean all viruses or bacteria become instantly inactive. Therefore, we should aim at minimum droplet spreading inside the cabin and different ventilation strategies for occupied cabins.”

After analyzing the results, the team determined the ideal use of ventilation systems to operate at medium flow rates of around 3 ACH when a cabin is occupied, to increase to 15 ACH for at least 12 minutes after it has been vacated. In this way, the air would be completely refreshed for the next occupants. They also recommend the same minimum time of 12 minutes as a “clearance wait time” for similar-sized rooms with a minimum of 15 ACH.

“Our main argument for the proposed values is the necessity to minimize droplet spreading while maintaining good ventilation levels, comfort and energy consumption,” said Drikakis. “Keeping ventilation at the proposed values reduces energy consumption and improves passenger comfort in contrast to the use of higher ventilation rates.”

###

The article “Virus spreading in cruiser cabin” is authored by Konstantinos Ritos, Dimitris Drikakis, and Ioannis W. Kokkinakis. The article will appear in Physics of Fluids on Oct. 31, 2023 (DOI: 10.1063/5.0169992.) After that date, it can be accessed at http://aip.scitation.org/doi/full/10.1063/5.0169992.

ABOUT THE JOURNAL

Physics of Fluids is devoted to the publication of original theoretical, computational, and experimental contributions to the dynamics of gases, liquids, and complex fluids. See https://pubs.aip.org/aip/pof.

###



Journal

Physics of Fluids

DOI

10.1063/5.0169992

Article Title

Virus spreading in cruiser cabin

Article Publication Date

31-Oct-2023

Share12Tweet8Share2ShareShareShare2

Related Posts

Harnessing Microwaves to Boost Energy Efficiency in Chemical Reactions

Harnessing Microwaves to Boost Energy Efficiency in Chemical Reactions

October 10, 2025
Wirth Named Fellow of the American Physical Society

Wirth Named Fellow of the American Physical Society

October 10, 2025

UTA Physicist Secures $1.3 Million Grant to Advance Neutrino Research

October 10, 2025

Energy Savings at Home Are Driven by Attitudes, Not Income

October 10, 2025

POPULAR NEWS

  • Sperm MicroRNAs: Crucial Mediators of Paternal Exercise Capacity Transmission

    1201 shares
    Share 480 Tweet 300
  • New Study Reveals the Science Behind Exercise and Weight Loss

    102 shares
    Share 41 Tweet 26
  • New Study Indicates Children’s Risk of Long COVID Could Double Following a Second Infection – The Lancet Infectious Diseases

    96 shares
    Share 38 Tweet 24
  • Revolutionizing Optimization: Deep Learning for Complex Systems

    84 shares
    Share 34 Tweet 21

About

BIOENGINEER.ORG

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

Tackling Inappropriate Prescribing Cascades for Safer Meds

New Inhibitor 4′-O-methylochnaflavone Targets HSP90AB1 in Cancer

Cold-Tolerant Germination in Hulless Barley Uncovered!

Subscribe to Blog via Email

Success! An email was just sent to confirm your subscription. Please find the email now and click 'Confirm' to start subscribing.

Join 63 other subscribers
  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.