In an experimental campaign conducted in the atmospheric boundary layer test section of the Politecnico di Milano wind tunnel, researchers demonstrated that the aerodynamic response and structural damping of a downstream floating wind turbine depend directly on how its platform motion synchronizes with the periodic wake fluctuations shed by an upstream turbine. Floating wind turbines mounted on compliant offshore platforms oscillate continuously under hydrodynamic wave action, shedding unsteady wakes characterized by rhythmic velocity variations that travel downwind. While earlier investigations primarily examined how isolated floating turbines influence their immediate wakes or how fixed structures respond to fluctuating inflows, this controlled tandem experiment isolated the dynamic coupling that arises when both machines move simultaneously. The resulting measurements demonstrate that wake-rotor synchronization is fundamentally phase dependent, showing that relative motion alignment between tandem floating turbines can either reinforce aerodynamic thrust oscillations or suppress them, altering the effective aerodynamic damping that governs floating platform stability.
The experimental setup evaluated two 1:150-scale models of the DTU 10 MW reference wind turbine arranged in a direct tandem layout aligned with the mean flow direction inside the 13.84-meter-wide, 3.84-meter-high, and 35-meter-long wind tunnel facility. The downstream unit, designated WT2, was installed at an inter-turbine spacing of 5.75 rotor diameters behind the upstream machine, WT1. Each scaled turbine featured a 1.2-meter rotor diameter equipped with blades fabricated using the SD7032 airfoil profile, which was specifically tailored to match the full-scale rotor thrust characteristics and aerodynamic sensitivities at low chord Reynolds numbers between 50,000 and 100,000. Both turbines were mounted atop dedicated robotic platforms incorporating a parallel kinematic mechanism designed to deliver precise harmonic translations along the surge axis. To isolate the physics of platform motion from background atmospheric fluctuations, the tests were conducted under uniform, low-turbulence inflow conditions with an ambient turbulence intensity of approximately 2 percent across most of the rotor swept area and a reference hub-height wind speed of 4.9 meters per second.
Dynamic scaling governing the experiment combined geometric scaling of 1:150 and velocity scaling of 1:2.5, resulting in a time scale of 1:60 that caused model dynamics to evolve sixty times faster than full-scale systems. To isolate pure aerodynamic interactions, both turbines operated at fixed collective blade pitch of zero degrees and constant rotational speeds, intentionally excluding active control feedback. The upstream turbine operated at 570 revolutions per minute to maintain an optimal tip-speed ratio of 7.3 in the undisturbed inflow, where it produced a baseline mean thrust of 13.1 newtons and 22.14 watts of aerodynamic power. The downstream turbine, operating inside the slower wake field where the effective inflow speed was estimated at 3.1 meters per second using blade-element momentum inversions of fixed-base thrust, was operated at 360 revolutions per minute to match the nominal tip-speed ratio of 7.3, generating 2.14 watts and 4.5 newtons of thrust in its stationary baseline configuration.
To represent the primary rigid-body natural modes of full-scale floating platforms, the authors subjected the models to prescribed sinusoidal surge oscillations at two motion frequencies: 0.5 hertz and 2.0 hertz, corresponding to rotor reduced frequencies of 0.12 and 0.48, respectively. The lower reduced frequency of 0.12 was chosen to represent platform surge natural modes, which typically span 0.005 to 0.01 hertz at full scale, while the higher reduced frequency of 0.48 represented platform pitch natural modes spanning 0.028 to 0.04 hertz. Motion amplitudes were calibrated to maintain an identical normalized apparent-wind-speed variation of 5 percent of the free-stream velocity for the upstream turbine, requiring a surge displacement amplitude of 0.08 meters (0.067 rotor diameters) at 0.12 reduced frequency and 0.02 meters (0.017 rotor diameters) at 0.48 reduced frequency. The relative phase offset between the surge displacements of the upstream and downstream machines was systematically adjusted across four discrete increments of 0, 90, 180, and 270 degrees to capture a complete motion cycle.
High-resolution aerodynamic and flow-field diagnostics tracked how energy propagated through the tandem array. Aerodynamic rotor loads were recorded using six-component ATI Mini45 strain-gauge force transducers situated at the tower-top nacelle interface, while wake flow fields were mapped using automated traversing hot-wire anemometers sampled at 10 kilohertz. To isolate aerodynamic forces from the total recorded signals, the researchers conducted identical motion trials under no-wind conditions with stationary rotors to measure platform inertial forces directly, subtracting these inertial baselines from the wind-on measurements before applying a 3-hertz low-pass filter and phase averaging across eighty consecutive motion periods. The resulting aerodynamic thrust was decomposed into an in-phase component aligned with platform displacement and a velocity-proportional quadrature component, yielding the equivalent aerodynamic damping coefficient that determines whether aerodynamic forces act to damp or amplify platform surge vibrations.
Analysis of the upstream turbine revealed that surge motion generated coherent velocity pulsations in its wake that matched the imposed motion frequency precisely. While the time-averaged mean velocity profiles at 3.5 rotor diameters downstream exhibited only modest deviations from stationary tower conditions, unsteady wake dynamics differed markedly between the two excitation regimes. At the lower reduced frequency of 0.12, velocity oscillations were modest and spatially localized, producing a peak-to-peak cross-sectional velocity amplitude of 0.03 relative to the free-stream velocity. In contrast, at the higher reduced frequency of 0.48, the wake developed powerful, coherent pulsations reaching local amplitudes up to 0.15 of the free-stream velocity and a spatially averaged peak-to-peak fluctuation of 0.10. Furthermore, the wake core and outer wake edges oscillated in counter-phase due to radial differences in convective advection velocities across the wake profile, where slower centerline advection delayed the arrival of rotor perturbations relative to the faster peripheral flow.
When these advecting wake structures reached the moving downstream rotor, the aerodynamic load response of the second turbine became strongly coupled to the relative phase offset between the two machines. In the intermediate benchmark configuration where only the upstream turbine oscillated while the downstream turbine remained stationary, the periodic wake pulses alone induced downstream thrust fluctuations equal to roughly one-third of the upstream oscillation amplitude. Conversely, when both turbines moved simultaneously, their relative motion determined whether the incoming wake velocity variations reinforced or counteracted the relative velocity induced by the downstream turbine’s own physical displacement. When the turbines surged completely in phase at a zero-degree offset, the incoming wake acceleration arrived as the downstream rotor translated upwind, constructively amplifying apparent wind speed variations and generating the maximum thrust oscillation amplitude observed in the downstream rotor.
This constructive synchronization directly affected the equivalent aerodynamic damping governing downstream platform stability. Aerodynamic damping requires thrust forces to oppose structural velocity, which corresponds to an aerodynamic phase lag near minus ninety degrees relative to displacement. Under in-phase surge motion at a zero-degree offset, the downstream turbine maintained an optimal force-motion phase relationship close to minus ninety degrees, causing its equivalent aerodynamic damping coefficient to reach 90 to 92 percent of the upstream reference value across both reduced frequencies. However, when the platforms moved in anti-phase at a 180-degree offset, destructive interference occurred: incoming wake decelerations coincided with upwind rotor travel, attenuating the apparent wind velocity variations and shifting the force phase away from the velocity axis. Consequently, under anti-phase motion, the equivalent aerodynamic damping dropped sharply to between 48 and 49 percent of the upstream turbine value, effectively halving the aerodynamic stabilization of the downstream platform.
Across all evaluated operational configurations, the equivalent aerodynamic damping of the downstream turbine remained systematically lower than that of the upstream machine. Even in the absence of upstream wake pulsations, when the downstream turbine surged behind a fixed upstream tower, the reduced mean inflow velocity within the wake deficit decreased baseline thrust sensitivity and lowered aerodynamic damping. Introducing dynamic wake coupling caused the downstream damping coefficient to fluctuate dramatically between 48 and 92 percent of the upstream baseline purely as a function of platform motion phase. Because this systematic phase dependency appeared with nearly identical magnitude at both 0.12 and 0.48 reduced frequencies, the researchers concluded that relative motion phasing exerts a considerably stronger influence over downstream dynamic loading and aerodynamic damping than the specific oscillation frequency of the floating platforms.
The experiments also revealed distinct frequency-dependent effects on wake recovery and array-level energy production. Surge motion at the lower reduced frequency of 0.12 did not produce measurable increases in time-averaged wake velocity or downstream power output. In sharp contrast, surge motion at the pitch-representative reduced frequency of 0.48 stimulated stronger coherent mixing that accelerated wake recovery behind the upstream machine, increasing the spatially averaged mean velocity at 3.5 diameters by 4.4 percent (a 0.12 meter per second gain). This enhanced momentum entrainment raised the effective inflow speed at the downstream rotor, producing a measurable gain in downstream turbine power that peaked under in-phase motion, which carried through to a modest increase in total farm power output. Wake measurements behind the second turbine demonstrated that downstream velocity recovery was primarily inherited from the motion-induced wake modulation initiated by the upstream turbine rather than generated locally by the downstream rotor.
The authors emphasized that while these wind tunnel trials provide definitive experimental proof of wake-rotor synchronization, several physical idealizations define the scope of the findings. The experiment employed scaled, rigid turbine models with constant operational setpoints under uniform, low-turbulence inflow, whereas commercial floating offshore wind farms encounter sheared atmospheric boundary layers with higher background turbulence that may diffuse coherent wake structures more rapidly. Furthermore, full-scale floating platforms undergo complex six-degree-of-freedom motions excited by irregular multi-directional wave spectra rather than idealized single-axis harmonic surge, and commercial turbines utilize dynamic pitch and torque controllers that continuously adjust rotor aerodynamics. Nevertheless, the discovery that tandem wake interactions can cut downstream aerodynamic damping by half highlights a dynamic coupling mechanism unique to floating offshore wind arrays, indicating that floating wind farm design and stability assessments must explicitly incorporate phase-dependent wake-rotor interactions.
Subject of Research: Aerodynamic coupling and phase-dependent wake-rotor synchronization between tandem floating wind turbines
Article Title: Experimental evidence of wake–rotor synchronization and its effects on the aerodynamic response of tandem floating wind turbines
Article References: Fontanella, A., Fusetti, A., Muggiasca, S., Dossena, V., & Belloli, M. (2026). Experimental evidence of wake–rotor synchronization and its effects on the aerodynamic response of tandem floating wind turbines. Wind Energy Science, 11(11), 4305-4333. https://doi.org/10.5194/wes-11-4305-2026
Image Credits: AI Generated
Keywords: floating offshore wind, wind tunnel experiment, wake-rotor synchronization, aerodynamic damping, tandem wind turbines, platform surge motion, reduced frequency, wake recovery, thrust oscillations, equivalent damping coefficient, coherent flow structures, DTU 10 MW reference turbine, streamwise velocity fluctuations, apparent wind speed, wind farm aerodynamics, dynamic wake modulation, unsteady aerodynamics
News Source: Faith Mcneil. (November 16, 2026). Floating Wind Turbine Wake Synchronization Substantially Alters Downstream Aerodynamic Damping. Scienmag.