• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Saturday, September 20, 2025
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News

Making X-ray microscopy 10 times faster

Bioengineer by Bioengineer
November 19, 2018
in Science News
Reading Time: 3 mins read
0
Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

Credit: Brookhaven National Laboratory

Microscopes make the invisible visible. And compared to conventional light microscopes, transmission x-ray microscopes (TXM) can see into samples with much higher resolution, revealing extraordinary details. Researchers across a wide range of scientific fields use TXM to see the structural and chemical makeup of their samples–everything from biological cells to energy storage materials.

Now, scientists at the National Synchrotron Light Source II (NSLS-II)–a U.S. Department of Energy (DOE) Office of Science User Facility at DOE's Brookhaven National Laboratory–have developed a TXM that can image samples 10 times faster than previously possible. Their research is published in Applied Physics Letters.

"We have significantly improved the speed of x-ray microscopy experiments," said Wah-Keat Lee, lead scientist at NSLS-II's Full Field X-ray Imaging (FXI) beamline, where the microscope was built. At FXI, Lee and his colleagues reduced the time it takes a TXM to image samples in 3-D from over 10 minutes to just one minute, while still producing images with exceptional 3-D resolution–below 50 nanometers, or 50 billionths of a meter. "This breakthrough will enable scientists to visualize their samples much faster at FXI than at similar instruments around the world," Lee said.

Aside from reducing the time it takes to complete an experiment, a faster TXM can collect more valuable data from samples.

"The holy grail of almost all imaging techniques is to be able to see a sample in 3-D and in real time," Lee said. "The speed of these experiments is relevant because we want to observe changes that happen quickly. There are many structural and chemical changes that happen on different time scales, so a faster instrument can see a lot more. For example, we have the ability to track how corrosion happens in a material, or how well various parts of a battery are performing."

To offer these capabilities at FXI, the team needed to build a TXM using the latest developments in ultrafast nano-positioning (a method of moving a sample while limiting vibrations), sensing (a method of tracking sample movement), and control. The new microscope was developed in-house at Brookhaven Lab through a collaborative effort between the engineers, beamline staff, and research and development teams at NSLS-II.

The researchers said developing superfast capabilities at FXI also strongly depended on the advanced design of NSLS-II.

"Our ability to make FXI more than 10 times faster than any other instrument in the world is also due to the powerful x-ray source at NSLS-II," Lee said. "At NSLS-II, we have devices called damping wigglers, which are used to achieve the very small electron beams for the facility. Fortunately for us, these devices also produce a very large number of x-rays. The amount of these powerful x-rays directly relates to the speed of our experiments."

Using the new capabilities at FXI, the researchers imaged the growth of silver dendrites on a sliver of copper. In a single minute, the beamline captured 1060 2-D images of the sample and reconstructed them to form a 3-D snapshot of the reaction. Repeating this, the researchers were able to form a minute-by-minute, 3-D animation of the chemical reaction.

"We chose to image this reaction because it demonstrates the power of FXI," said Mingyuan Ge, lead author of the research and a scientist at NSLS-II. "The reaction is well-known, but it has never been visualized in 3-D with such a fast acquisition time. In addition, our spatial resolution is 30 to 50 times finer than optical microscopy used in the past."

With the completion of this research, FXI has begun its general user operations, welcoming researchers from around the world to use the beamline's advanced capabilities.

###

Brookhaven National Laboratory is supported by the Office of Science of the U.S. Department of Energy. The Office of Science is the single largest supporter of basic research in the physical sciences in the United States, and is working to address some of the most pressing challenges of our time. For more information, please visit science.energy.gov.

Follow @BrookhavenLab on Twitter or find us on Facebook.

Media Contact

Stephanie Kossman
[email protected]
631-344-8671
@brookhavenlab

http://www.bnl.gov

Original Source

https://www.bnl.gov/newsroom/news.php?a=213151 http://dx.doi.org/10.1063/1.5048378

Share12Tweet8Share2ShareShareShare2

Related Posts

Caffeine Exposure Shapes Neurodevelopment in Premature Infants

Caffeine Exposure Shapes Neurodevelopment in Premature Infants

September 20, 2025

Impact of Defect Size and Location on Spinal Fractures

September 20, 2025

New Metabolic Syndrome Score Validated in Teens

September 20, 2025

Low PDA Shunt Linked to Premature Infant Risks

September 20, 2025
Please login to join discussion

POPULAR NEWS

  • blank

    Breakthrough in Computer Hardware Advances Solves Complex Optimization Challenges

    156 shares
    Share 62 Tweet 39
  • Physicists Develop Visible Time Crystal for the First Time

    68 shares
    Share 27 Tweet 17
  • Tailored Gene-Editing Technology Emerges as a Promising Treatment for Fatal Pediatric Diseases

    49 shares
    Share 20 Tweet 12
  • Scientists Achieve Ambient-Temperature Light-Induced Heterolytic Hydrogen Dissociation

    48 shares
    Share 19 Tweet 12

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

Caffeine Exposure Shapes Neurodevelopment in Premature Infants

Impact of Defect Size and Location on Spinal Fractures

New Metabolic Syndrome Score Validated in Teens

  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.