• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Saturday, February 7, 2026
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Health

New diagnostic technique picks up the S in vision

Bioengineer by Bioengineer
May 1, 2018
in Health
Reading Time: 3 mins read
0
Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

A new technique that could help improve diagnosis of vision disorders has been successfully tested at the University of Bradford, UK.

The researchers showed the technique can isolate responses from the different retinal cells that we use to see, including those that are most vulnerable to damage and disease, known as S-cone photoreceptors.

Diseases that affect S-cones include Types 1 and 2 diabetes, glaucoma and high blood pressure and some rare genetic disorders, such as enhanced S-cone syndrome and blue cone monochromatism.

S-cone photoreceptors respond to light of short wavelengths and help us see the blue part of the colour spectrum. However, it is difficult to test their function independently of the other types of photoreceptor in the eye: L-cone (long wavelength covering the red spectrum), M-cone (medium wave-length covering the yellow and green spectrum) and rod photoreceptors, that help us see when light levels are low.

Study lead, Dr Declan McKeefry, from the University of Bradford's School of Optometry conducts clinical diagnostics of vision disorders for the NHS. He says: "Diagnosis of some eye diseases can be difficult as they have similar symptoms, such as blurred or distorted vision and inability to see colour, and often a variety of genetic causes. Understanding exactly which cells are affected in the eye can be the key piece of the jigsaw that enables an accurate diagnosis, but until now, it's been almost impossible to test the function of the S-cones separately."

The standard method of diagnosis involves flashing lights at the eye, and measuring the response using an electroretinogram (ERG) – similar to an ECG used to measure heart activity. But because this picks up responses from all the retinal photoreceptors, it can mask certain diseases where S-cones are disproportionately affected.

Dr McKeefry used stimuli at different wavelengths to 'silence' the L- and M-cones and the rods so only the signals from the S-cones are picked up. The technique is the first to silence these three together and so is known as 'triple silent substitution'.

He tested the technique on 16 volunteers with normal colour vision, two patients previously diagnosed with blue cone monochromatism (BCM) and one patient who has enhanced S-cone syndrome (ESCS).

BCM is a genetic disorder where the L- and M-cones don't function at all, leading to impaired colour vision. In ESCS, there are higher numbers of S-cones in the retina which are hyper-sensitive, crowding out the L- and M-cones.

Dr McKeefry's tests showed exactly the results that would be expected from these three types of volunteers – normal signals from all three cones in the healthy volunteers, no response from L- and M-cones in the BCM patients and an overactive response from the S-cones in the ESCS patient. Together, this showed that the responses from the S-cones were being picked up independently of the other cells, proving the technique could be used confidently for assessing S-cone activity or damage.

Dr McKeefry says: "Because we know that there are no active L- and M-cones in BCM patients, this shows that our technique is effectively isolating the right photoreceptors, as we only got signals from the S-cones. This means we could use the technique to spot damage in the S-cones or an altered pattern, as in ESCS, which could help in diagnosis of this condition."

While currently there are no treatments for BCM or ESCS, recent medical advances do hold out hope, as Dr McKeefry explains: "Stem cell therapy has been shown to help restore eye function so this is a route that holds potential for these rare genetic disorders. But for that kind of therapy to work, it's even more important to know which cells are affected by the disease, and triple silent substitution can help us to do that much more accurately."

###

The research is published in the current issue of the Journal of the Optical Society of America.

Media Contact

Mark Thompson
[email protected]
44-012-742-36510
@BradfordUni

http://www.bradford.ac.uk

http://dx.doi.org/10.1364/JOSAA.35.000B11

Share12Tweet7Share2ShareShareShare1

Related Posts

Evaluating Pediatric Emergency Care Quality in Ethiopia

February 7, 2026

TPMT Expression Predictions Linked to Azathioprine Side Effects

February 7, 2026

Improving Dementia Care with Enhanced Activity Kits

February 7, 2026

Decoding Prostate Cancer Origins via snFLARE-seq, mxFRIZNGRND

February 7, 2026
Please login to join discussion

POPULAR NEWS

  • Robotic Ureteral Reconstruction: A Novel Approach

    Robotic Ureteral Reconstruction: A Novel Approach

    82 shares
    Share 33 Tweet 21
  • Digital Privacy: Health Data Control in Incarceration

    63 shares
    Share 25 Tweet 16
  • Study Reveals Lipid Accumulation in ME/CFS Cells

    57 shares
    Share 23 Tweet 14
  • Breakthrough in RNA Research Accelerates Medical Innovations Timeline

    53 shares
    Share 21 Tweet 13

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

Evaluating Pediatric Emergency Care Quality in Ethiopia

TPMT Expression Predictions Linked to Azathioprine Side Effects

Improving Dementia Care with Enhanced Activity Kits

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 73 other subscribers
  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.