• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Thursday, November 26, 2026
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Chemistry

UHPLC-UV Method Quantifies Trace Packaging Leachables Below Pharmaceutical Safety Reporting Thresholds

by
November 26, 2026
in Chemistry
Reading Time: 6 mins read
0
UHPLC-UV Method Quantifies Trace Packaging Leachables Below Pharmaceutical Safety Reporting Thresholds

UHPLC-UV Method Quantifies Trace Packaging Leachables Below Pharmaceutical Safety Reporting Thresholds

Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

Analytical scientists have successfully developed and validated a sensitive ultra-high-performance liquid chromatography ultraviolet method capable of screening and simultaneously quantifying fourteen critical plastic additives and degradation products that can migrate from pharmaceutical packaging materials into medicinal formulations. The investigation, detailed in Talanta Open, addresses the complex analytical challenge of monitoring extractables and leachables that enter drug solutions from contact materials such as polymeric container closure systems and disposable single-use systems during manufacturing, storage, and clinical handling. Regulatory authorities, including the European Medicines Agency, the United States Pharmacopeia, and the United States Food and Drug Administration, enforce rigorous testing mandates because chemical migrants from packaging containers can introduce toxicological risks depending on their molecular composition and administered concentration. The research demonstrates that direct ultraviolet detection at a low monitoring wavelength can reliably measure diverse chemical impurities down to single-digit nanogram per milliliter limits of quantitation, offering a high-throughput, cost-effective screening approach for routine pharmaceutical quality control without demanding complex solid-phase extraction pre-concentration steps.

The study established its quantitative analytical performance targets by translating clinical safety guidelines into measurable chromatographic limits using the analytical evaluation threshold concept defined in United States Pharmacopeia general chapters 1663 and 1664. Because screening for migrating packaging impurities is inherently non-targeted and unknown leachables might theoretically possess mutagenic properties, toxicological thresholds are mathematically calculated from conservative exposure models. For the target drug model investigated in this study, tranexamic acid injection, clinical administration is delivered over a limited therapeutic duration rather than a continuous lifetime exposure scenario. Using a maximum daily dose of 2800 milligrams per day, corresponding to a fluid volume of 280 milliliters per day at the therapeutic formulation concentration, and a safety concern threshold of 120 micrograms per day derived from the ICH M7 regulatory guideline for exposures up to approximately one month, the researchers calculated an analytical evaluation threshold of 0.429 micrograms per milliliter, or 429 nanograms per milliliter. This threshold establishes the exact reporting benchmark that mandates chemical characterization and formal toxicological review.

To overcome the selectivity and retention challenges posed by structurally diverse chemical additives that range from low-molecular-weight aromatic aldehydes to high-molecular-weight hindered phenolic antioxidants, the investigators systematically optimized chromatographic separation conditions on an Acquity ultra-performance liquid chromatography platform. Preliminary evaluations using conventional octadecylsilane C18 columns and phenyl-hexyl stationary phases failed to achieve acceptable baseline resolution due to the wide polarity range of the fourteen target analytes. The team achieved superior chromatographic selectivity by scaling to a 100-millimeter ACE Excel C18-PFP column containing pentafluorophenyl functionality packed with 1.7-micrometer particles, which supplied complementary retention mechanisms encompassing hydrophobic interactions, pi-pi interactions, dipole-dipole forces, and hydrogen bonding. Utilizing a mobile phase of 0.01 percent formic acid in water paired with 0.01 percent formic acid in acetonitrile pumped at 0.4 milliliters per minute under a 25-minute multi-step gradient ramp from 30 percent to 96.5 percent organic modifier, the system achieved baseline separation with resolution factors exceeding 2.0 across all critical analyte pairs while keeping the column temperature at 40 degrees Celsius.

Instrumental detection was established at an optimized single monitoring wavelength of 210 nanometers using a photodiode array detector equipped with a median baseline filter to suppress low-frequency baseline fluctuations without sacrificing peak integration symmetry. Testing alternative wavelengths between 210 and 254 nanometers confirmed that higher wavelengths progressively diminished detector responses for multiple plastic additives that lack extensive conjugated chromophores. To reach single-digit nanogram per milliliter sensitivity without introducing peak distortion, the researchers investigated sample diluent compositions across various water and acetonitrile ratios. Formulating standard and sample solutions in 100 percent water suppressed band broadening for early-eluting polar constituents, allowing an injection volume of 100 microliters into a 250-microliter autosampler loop. In parallel, fine-tuning the mobile phase acid modifier showed that dropping formic acid content down to 0.01 percent reduced baseline noise substantially, thereby maximizing signal-to-noise ratios across the run while preserving chromatographic compatibility with downstream electrospray ionization mass spectrometry.

The multi-analyte chromatographic method underwent comprehensive performance validation across all core parameters outlined in the ICH Q2(R2) regulatory guidelines. Linearity was validated over individual dynamic ranges spanning from the respective limit of quantitation of each target compound up to 1000 nanograms per milliliter, yielding least-squares linear regression coefficients of determination between 0.994 and 1.000. Experimental limits of quantitation, established practically at signal-to-noise ratios between 10:1 and 20:1, ranged from 1.0 to 30.4 nanograms per milliliter, comfortably below the calculated 429 nanogram per milliliter analytical evaluation threshold. Accuracy and precision were confirmed through triplicate recovery trials in tranexamic acid drug matrix spiked at the quantitation limit, 500 nanograms per milliliter, and 750 nanograms per milliliter. Mean analytical recoveries ranged from 83.60 percent to 118.8 percent across all spiked concentrations with relative standard deviations consistently below 2.0 percent, satisfying predefined acceptance criteria. Method robustness was demonstrated by systematically introducing deliberate minor variations in flow rate, column temperature, mobile phase acidity, and cross-instrument testing on a second equivalent chromatographic system.

To eliminate the burdensome requirement of preparing fourteen individual reference standards for every routine analytical sequence, the methodology adopted a surrogate standardization workflow utilizing 3,5-di-tert-butyl-4-hydroxybenzoic acid. This target analyte was selected as the internal surrogate calibrant because its ultraviolet absorption response closely approximated the mean detector response of the fourteen target analytes and it exhibited superior chemical stability in aqueous solutions compared to sensitive antioxidants like butylated hydroxytoluene. Stability assessments demonstrated that working solutions of the surrogate compound stored at ambient temperature of 25 degrees Celsius and refrigerated storage at 5 degrees Celsius retained peak area recoveries within 90 to 110 percent of initial values for up to 21 days. Experimentally determined relative response factors calculated from calibration slope ratios enabled accurate direct quantification of target migrants and reliable semi-quantitation of newly emerging unknown peaks, substantially accelerating screening throughput while maintaining high analytical fidelity in routine quality environments.

The validated method was systematically deployed to profile chemical extractables released from commercial 100-milliliter polypropylene infusion bags subjected to exaggerated accelerated thermal stress at 60 degrees Celsius over intervals of one, three, and seven days. To simulate diverse formulation matrices, extractions were conducted across purified water and 0.7 percent sodium chloride saline adjusted to acidic pH 2.0, physiological pH 6.5, and alkaline pH 9.5, alongside organic extractions using an equal-volume mixture of isopropanol and water. Contact geometry was maintained at a surface-area-to-volume ratio of 6 square centimeters per milliliter by venting container headspace prior to thermal incubation. Comparative aqueous profiling revealed no meaningful differences in migrant identity or concentration between pure water and saline at pH 2.0 or 6.5, showing that dissolved sodium chloride does not influence migration under acidic or neutral conditions. However, under alkaline conditions at pH 9.5, migration of 3-(3,5-di-tert-butyl-4-hydroxyphenyl)propionic acid exhibited noticeably lower measured concentrations in saline than in purified water, confirming that ionic strength alters extraction behavior in basic environments.

Thermal extraction testing revealed distinct chemical kinetics and secondary degradation pathways occurring within the polypropylene containers over the seven-day heating duration. Concentrations of degraded carboxylic acid derivatives such as 3-(3,5-di-tert-butyl-1-hydroxy-4-oxocyclohexa-2,5-dien-1-yl)propionic acid and 3-(3,5-di-tert-butyl-4-hydroxyphenyl)propionic acid increased progressively over time, whereas levels of the parent spiro compound 7,9-di-tert-butyl-1-oxaspiro[4.5]deca-6,9-diene-2,8-dione and 2,4-di-tert-butylphenol declined. In aqueous solutions, the spiro intermediate undergoes hydrolytic ring opening to form the corresponding cyclohexadienyl propionic acid derivative. Strikingly, organic extraction with isopropanol and water yielded 2,4-di-tert-butylphenol as the most abundant migrant, reaching 5608.4 nanograms per milliliter at seven days, but showed a complete absence of the cyclohexadienyl transformation product, verifying that the latter compound arises entirely through secondary aqueous hydrolysis. Furthermore, benzyl butyl phthalate was observed only transiently at early time points before hydrolyzing into phthalic acid under continued thermal stress, and twenty hydrophobic unknown compounds were detected in organic extracts.

To resolve the molecular structures of unknown late-eluting migrants detected during organic solvent extractions, the authors coupled their chromatographic separation to high-resolution quadrupole time-of-flight mass spectrometry operating in electrospray ionization mode. Using alternating low-energy and high-energy collision ramps within an MSe acquisition mode, intact precursor ions and diagnostic product fragments were gathered simultaneously with mass measurement errors under 5 parts per million. This structural elucidation platform yielded putative identifications for four high-molecular-weight hindered phenolic antioxidants: pentaerythritol bis(3,5-di-tert-butyl-4-hydroxyhydrocinnamate) eluting at 18.11 minutes with a precursor ion at m/z 655.4213, pentaerythritol tris(3,5-di-tert-butyl-4-hydroxyhydrocinnamate) eluting at 19.58 minutes with m/z 915.5983, intact Irganox 1010 eluting at 21.24 minutes with m/z 1175.7739, and the oxidized secondary antioxidant Irgafos 168 phosphate eluting at 21.81 minutes with m/z 663.4212. Sequential neutral losses of approximately 260 Daltons observed across the pentaerythritol cluster confirmed the stepwise loss of repeating hindered phenolic ester substituents, providing robust chemical identification despite the absence of commercially available reference standards.

Finally, the authors evaluated the practical fitness-for-purpose of their analytical platform by monitoring real-time leachable migration in finished tranexamic acid drug product stored inside polypropylene infusion bags at room temperature over a six-month stability interval. Baseline analyses conducted immediately upon filling revealed no detectable target leachables. After three and six months of ambient storage, three known leachables emerged alongside four trace unknown components that each remained below 6 nanograms per milliliter. Among the identified migrants, 3-(3,5-di-tert-butyl-4-hydroxyphenyl)propionic acid was the most abundant species, stabilizing at 217.7 nanograms per milliliter at three months and 203.7 nanograms per milliliter at six months, followed by 3-(3,5-di-tert-butyl-1-hydroxy-4-oxocyclohexa-2,5-dien-1-yl)propionic acid at 97.3 and 85.7 nanograms per milliliter, and 3,5-di-tert-butyl-4-hydroxybenzoic acid at 3.6 and 2.8 nanograms per milliliter. Every observed leachable concentration remained well below the established 429 nanogram per milliliter analytical evaluation threshold throughout the six-month storage window, demonstrating the method’s real-world capability for packaging safety screening while confirming that definitive toxicological risk qualification remains an essential subsequent stage of comprehensive patient risk assessment.

Subject of Research: Chromatographic quantification and structural characterization of extractable and leachable chemical contaminants from polypropylene pharmaceutical packaging

Article Title: Development and validation of a highly sensitive UHPLC–UV method for quantitative analysis of extractables and leachables, complemented by lc-qtof for structural characterization of trace levels unknowns in pharmaceutical packaging

Article References: Elhawi, M., Cook, J., Rahman, M. A. A., Ramadan, A. E.-M. M., Sallam, S. A., & Abdel-Megied, A. M. (2026). Development and validation of a highly sensitive UHPLC–UV method for quantitative analysis of extractables and leachables, complemented by lc-qtof for structural characterization of trace levels unknowns in pharmaceutical packaging. Talanta Open, 14, Article 100702. https://doi.org/10.1016/j.talo.2026.100702

Image Credits: AI Generated

DOI: 10.1016/j.talo.2026.100702

Keywords: ultra-high-performance liquid chromatography, extractables and leachables, pharmaceutical packaging, polypropylene infusion containers, high-resolution mass spectrometry, quadrupole time-of-flight, tranexamic acid injection, analytical evaluation threshold, safety concern threshold, chromatographic method validation, pentaerythritol antioxidants, irganox 1010, irgafos 168 phosphate, hydrolytic degradation pathways, surrogate standardization, chemical impurity profiling, single-use systems, container closure systems

News Source: Bethany Barker. (November 26, 2026). UHPLC-UV Method Quantifies Trace Packaging Leachables Below Pharmaceutical Safety Reporting Thresholds. Scienmag.

Tags: analytical evaluation thresholdchemical impurity profilingchromatographic method validationcontainer closure systemsextractables and leachableshigh-resolution mass spectrometryhydrolytic degradation pathwaysirgafos 168 phosphateirganox 1010pentaerythritol antioxidantspharmaceutical packagingpolypropylene infusion containersquadrupole-time of flightsafety concern thresholdsingle-use systemssurrogate standardizationtranexamic acid injectionultra-high-performance liquid chromatography
Share12Tweet7Share2ShareShareShare1

Related Posts

Volatile Fingerprinting Establishes Hierarchical Biomarker Framework for Virgin Olive Oil Authentication

Volatile Fingerprinting Establishes Hierarchical Biomarker Framework for Virgin Olive Oil Authentication

November 26, 2026
Machine Learning and Rapid Screening Accelerate Design of Artificial Enzyme Catalysts

Machine Learning and Rapid Screening Accelerate Design of Artificial Enzyme Catalysts

November 26, 2026

Computational Modeling Maps Defect Chemistry and Carrier Dynamics in Perovskite Quantum Dots

November 26, 2026

Karlsruhe Researchers Win German Future Prize for 3D-Printed Optical Chip Connections

November 26, 2026

POPULAR NEWS

  • Deep Learning and IoT Architecture Enhances College Physical Education Performance Tracking

    Deep Learning and IoT Architecture Enhances College Physical Education Performance Tracking

    29 shares
    Share 12 Tweet 7
  • Medical Student Summer Research Shows No Association With Residency Match Prestige

    29 shares
    Share 12 Tweet 7
  • Computational Compound Bypasses Defective Insulin Receptors to Treat Severe Resistance in Mice

    29 shares
    Share 12 Tweet 7
  • Artificial Intelligence Predicts Hip Fracture Outcomes but Lacks Formal Economic Evaluation

    29 shares
    Share 12 Tweet 7

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

Collaborative Vision System Sorts Corn Ears Across Four Parallel High-Throughput Channels

Theoretical Framework Proposes Sociological and Tiered Architectures to Address AI Scaling Limits

Volatile Fingerprinting Establishes Hierarchical Biomarker Framework for Virgin Olive Oil Authentication

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 89 other subscribers
  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.