• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Thursday, November 26, 2026
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Health

Study Sets Baseline Radiation Doses for CTPA Scans During Pregnancy

by
November 26, 2026
in Health
Reading Time: 6 mins read
0
Study Sets Baseline Radiation Doses for CTPA Scans During Pregnancy

Study Sets Baseline Radiation Doses for CTPA Scans During Pregnancy

Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

A retrospective investigation conducted at a tertiary medical institution in Riyadh, Saudi Arabia, has established baseline institutional diagnostic reference levels for pregnant patients undergoing computed tomography pulmonary angiography to assess suspected pulmonary embolism. Documenting ten years of clinical practice involving 120 consecutive pregnant patients between October 2016 and March 2026, the investigation established a proposed 75th-percentile institutional benchmark of 14.43 milligrays for the volume computed tomography dose index and 357.36 milligray-centimetres for the dose–length product. Across the entire cohort, examinations generated a mean volume computed tomography dose index of 12.15 plus or minus 4.30 milligrays, with an observed median of 11.84 milligrays, and a mean dose–length product of 307.89 plus or minus 123.89 milligray-centimetres, accompanied by a median of 299.36 milligray-centimetres. Converting these acquisition measurements into normalized population-level figures yielded an estimated mean maternal effective dose of 4.31 plus or minus 1.73 millisieverts, matching the lower range of exposures documented in international medical literature.

Diagnosing acute pulmonary embolism during pregnancy represents a formidable clinical dilemma because the physiological adaptations inherent to gestation closely mirror the classical hallmarks of thrombotic disease, including exertional dyspnoea, resting tachycardia, and lower-extremity oedema. Under normal physiological circumstances, deep venous thromboembolism risk increases fivefold to tenfold throughout pregnancy and climbs up to sixtyfold during the postpartum stage. Despite this heightened vulnerability, objective diagnostic investigations confirm an actual clinical incidence ranging between 0.5 and 1.7 cases per 1000 deliveries. Compounding the diagnostic challenge, established clinical pre-test evaluation algorithms and serum D-dimer blood assays demonstrate diminished clinical reliability in pregnant cohorts, as circulating maternal D-dimer concentrations rise physiologically throughout gestational maturation. Consequently, clinicians must rely on objective diagnostic cross-sectional imaging, primarily computed tomography pulmonary angiography or ventilation-perfusion lung scintigraphy, to rule out life-threatening intravascular thromboembolism while minimizing ionizing exposure.

The study protocol captured every eligible patient examined at the facility under institutional review board ethical approval H-01-R-069, forming a complete institutional census across the decade-long window. Maternal ages ranged from 16 to 52 years, yielding a cohort mean of 33.53 plus or minus 6.78 years. Gestational trimester distribution was formally documented for 118 patients, revealing that 10.0 percent underwent scanning during the first trimester, 47.5 percent during the second trimester, and 40.8 percent during the third trimester, leaving two individuals with unrecorded gestational timing. Recorded maternal body mass index was retrieved for 92 patients, yielding a mean of 31.10 plus or minus 6.23 kilograms per square metre. Missing clinical variables were not statistically imputed, preserving empirical integrity across separate analytical evaluations. Out of 119 completed diagnostic interpretations, objective vascular filling defects positive for pulmonary embolism were confirmed in only 6 women, demonstrating an institutional diagnostic yield of 5.0 percent with an associated 95 percent confidence interval spanning from 2.3 percent to 10.6 percent.

Every patient examination was executed using the identical 64-slice GE LightSpeed VCT scanner equipped with a 64 by 0.625 millimetre detector geometry providing a maximum nominal coverage of 40 millimetres per gantry rotation. Technologists maintained a beam collimation width of 40 millimetres while operating in helical acquisition mode alongside automated tube-current modulation. Reconstructed axial slice thickness remained fixed at 1.25 millimetres across all scans. Gantry rotation times averaged 0.45 plus or minus 0.07 seconds within an operational range of 0.40 to 0.80 seconds, accompanied by an average pitch factor of 1.11 plus or minus 0.20 varying from 0.52 to 1.38. Image datasets were processed via filtered back projection combined with adaptive statistical iterative reconstruction blending, maintaining an average iterative blending strength of 67.58 plus or minus 14.61 percent across the cohort. Intravenous contrast administration utilized 50 to 60 millilitres of iso-osmolar iodixanol injected at 4.5 to 5.0 millilitres per second, monitored through main pulmonary artery bolus tracking triggering at 150 to 180 Hounsfield units with an aggregate diagnostic delay of 8 to 11 seconds.

Because clinical radiation dose indices regularly exhibit skewed distributional shapes, formal statistical tests were performed to verify distributional characteristics. Shapiro–Wilk assessments yielded significance levels below 0.001 for both volume computed tomography dose index and dose–length product, necessitating non-parametric analytical techniques to characterize institutional baselines and parameter relationships. The interquartile range for the volume computed tomography dose index spanned from 9.27 to 14.43 milligrays, around a facility-specific typical median of 11.84 milligrays. Simultaneously, the dose–length product interquartile range extended from 226.90 to 357.36 milligray-centimetres, around a median benchmark of 299.36 milligray-centimetres. Size-specific dose estimates, calculated across 116 available examinations, documented a mean of 14.41 plus or minus 4.75 milligrays, an observed median of 14.20 milligrays, and a 75th-percentile distribution ceiling of 16.56 milligrays, offering normalized tissue-level references across variable patient anatomies.

Estimated maternal effective doses were derived mathematically by applying a normalized anatomical region coefficient factor of 0.014 millisieverts per milligray-centimetre to each diagnostic acquisition dose–length product. This calculation generated an overall cohort 75th percentile of 5.00 millisieverts. Researchers stressed that this conventional mathematical formulation utilizes standardized reference phantoms to provide population-level indicators for departmental quality management, dose optimization, and protocol audits. The resulting metric does not account for idiosyncratic maternal internal anatomy, dynamic body habitus, physiological tissue alterations during pregnancy, or scanner-specific geometries. Accordingly, these effective dose figures cannot be construed as direct experimental measurements of individual maternal absorbed organ dose, maternal glandular breast tissue absorbed dose, or fetal whole-body absorbed dose, nor do they represent personalized biological radiation risk calculations.

To assess potential changes in radiation safety practices across the ten-year duration of scanner utilization, investigators stratified all 120 procedures across three temporal periods: 2016 through 2019 comprising 24 examinations, 2020 through 2022 comprising 21 examinations, and 2023 through 2026 comprising 75 examinations. The highest mean volumetric dose index and dose–length product emerged during the 2020 to 2022 block, averaging 14.16 plus or minus 5.50 milligrays and 364.90 plus or minus 162.68 milligray-centimetres, respectively. Nevertheless, non-parametric Kruskal–Wallis comparisons demonstrated no statistically significant differences across chronological blocks for the volume computed tomography dose index, the diagnostic dose–length product, or estimated effective dose. Although Spearman rank correlation identified a significant longitudinal reduction in tube voltage alongside a significant rise in iterative reconstruction strength, overall volumetric and accumulated doses remained steady over time. A temporal sensitivity analysis isolating the 75 examinations performed between 2023 and 2026 revealed 75th percentiles of 14.41 milligrays and 355.23 milligray-centimetres, confirming close alignment with full-cohort figures.

Correlative analyses identified significant relationships between specific physical parameters and delivered radiation doses. Maternal body mass index, available in 92 patients, displayed moderate positive correlations with both the volume computed tomography dose index and the dose–length product, confirming that maternal body bulk acts as a primary operational driver of radiation output when automated tube-current modulation dynamically adjusts photon flux. Total anatomical scan length, averaging 249.87 plus or minus 29.17 millimetres, exhibited a positive correlation with volume computed tomography dose index and an even stronger correlation with total dose–length product, underscoring that strict restriction of craniocaudal scan coverage directly curtails unnecessary exposure. Conversely, maternal age displayed only weak positive correlations with dose metrics and produced no statistically significant dose variation across stratified chronological age groupings.

Technical comparisons across tube voltage settings demonstrated significant shifts in volumetric dose density across the three applied peak potential levels. Out of 120 scans, 11 were acquired at 100 kilovolts peak, 105 at 120 kilovolts peak, and 4 at 140 kilovolts peak. Mean volume computed tomography dose index increased progressively from 10.94 plus or minus 2.56 milligrays at 100 kilovolts peak to 12.09 plus or minus 4.39 milligrays at 120 kilovolts peak and 16.87 plus or minus 2.75 milligrays at 140 kilovolts peak, representing a statistically significant overall group difference. Pairwise comparisons confirmed significantly higher volume computed tomography dose index at 140 kilovolts peak relative to both lower settings. However, neither total dose–length product nor estimated maternal effective dose reached statistical significance across tube voltage groups. Investigators cautioned against deriving definitive generalized clinical rules from these voltage stratifications, given that only four patients were imaged using the 140 kilovolts peak setting.

Evaluation across gestational trimesters demonstrated no statistically significant divergence in radiation exposure metrics. Mean estimated effective doses measured 4.47 plus or minus 1.52 millisieverts among 12 first-trimester patients, 4.19 plus or minus 1.24 millisieverts among 57 second-trimester patients, and 4.33 plus or minus 2.22 millisieverts among 49 third-trimester patients. These steady values contrast with published observations from earlier international cohorts that documented higher first-trimester effective exposures. Exploratory comparisons evaluating maternal characteristics and scanner parameters according to final pulmonary embolism outcomes likewise identified no statistically significant differences in age, body mass index, volume computed tomography dose index, or dose–length product between the 6 positive patients and the 113 negative patients, although authors noted that the very small number of confirmed positive cases precludes definitive conclusions.

Contextualized against external published cohorts, the observed institutional mean effective dose of 4.31 millisieverts aligns closely with multicentre findings of 3.96 millisieverts reported by Cohen and colleagues, while remaining substantially below older historical publications that recorded average doses of 9.8 millisieverts and 21.02 millisieverts. In the absence of published Saudi national reference levels dedicated specifically to pregnant cohorts, the proposed institutional reference level of 14.43 milligrays for volume computed tomography dose index was slightly below general adult Saudi national figures of 15 milligrays, while the proposed dose–length product reference level of 357.36 milligray-centimetres was markedly lower than the adult national level of 475 milligray-centimetres. International comparisons revealed that the proposed institutional values were higher than United Kingdom and European Union adult diagnostic reference levels but lower than United States national benchmarks, reflecting differing international acquisition standards.

The authors identified several key methodological limitations that temper direct extrapolation of their findings. The retrospective, single-scanner, single-centre framework precludes direct generalization to dissimilar scanner models, alternative detector geometries, or distinct patient populations across other healthcare centres. Furthermore, because observed bivariate correlations cannot prove independent or causal mechanisms, complex interactions between patient size, scan length, and automatic modulation require prospective validation. Crucially, the study did not measure direct uterine or breast absorbed doses, relying instead on reference phantom coefficients that cannot quantify individual biological risks. Nonetheless, when clinically indicated for suspected pulmonary embolism, an optimized computed tomography pulmonary angiography protocol provides crucial life-saving diagnostic benefits while establishing reproducible local baselines to govern continuous clinical quality monitoring.

Subject of Research: Institutional diagnostic reference levels and radiation dose assessment for CT pulmonary angiography in pregnant patients

Article Title: Radiation dose and institutional diagnostic reference level for CT pulmonary angiography among pregnant women: A single-centre study

Article References: Albeshan, S., Alghamdi, S. B., Alanazi, A., & Almasoud, M. I. (2026). Radiation dose and institutional diagnostic reference level for CT pulmonary angiography among pregnant women: A single-centre study. Journal of Radiation Research and Applied Sciences, 19(4), Article 102846. https://doi.org/10.1016/j.jrras.2026.102846

Image Credits: AI Generated

DOI: 10.1016/j.jrras.2026.102846

Keywords: computed tomography pulmonary angiography, diagnostic reference levels, radiation dose, pregnancy, pulmonary embolism, volume CT dose index, dose length product, effective dose, maternal imaging, automatic tube current modulation, tube voltage, body mass index, scan length, retrospective cohort, thoracic radiology, radiation protection, medical physics, helical CT

News Source: Harold Sullivan. (November 26, 2026). Study Sets Baseline Radiation Doses for CTPA Scans During Pregnancy. Scienmag.

Tags: automatic tube current modulationbody-mass indexcomputed tomography pulmonary angiographydiagnostic reference levelsdose-length producteffective dosehelical CTmaternal imagingmedical physicsPregnancypulmonary embolismRadiation Doseradiation protectionRetrospective Cohortscan lengthThoracic Radiologytube voltagevolume CT dose index
Share12Tweet7Share2ShareShareShare1

Related Posts

Sex Hormones Shape Brain Plasticity and Cognitive Function Across Human Lifespan

Sex Hormones Shape Brain Plasticity and Cognitive Function Across Human Lifespan

November 26, 2026
Saudi Arabia Faces 16-Fold Clinical Trial Gap Despite Pharmaceutical Growth

Saudi Arabia Faces 16-Fold Clinical Trial Gap Despite Pharmaceutical Growth

November 26, 2026

Hospital Study in Kenya Finds Household Energy Causes Most Severe Burns

November 26, 2026

Young Women View Cosmetic Injectables as Low Risk Routine Adjustments

November 26, 2026

POPULAR NEWS

  • Precision Public Health Conference Emphasizes Workforce Capacity and Diverse Genomic Reference Data

    Precision Public Health Conference Emphasizes Workforce Capacity and Diverse Genomic Reference Data

    29 shares
    Share 12 Tweet 7
  • Trigger-Point Acupuncture Alleviates Synovial Inflammation in Osteoarthritic Rabbits

    29 shares
    Share 12 Tweet 7
  • Electrospun Ferula Gum and Postbiotic Nanofibers Extend Refrigerated Chicken Fillet Shelf Life

    29 shares
    Share 12 Tweet 7
  • NHS Study Finds Inpatient Restraint Rates Vary Widely Across Psychiatric Wards

    29 shares
    Share 12 Tweet 7

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

Sex Hormones Shape Brain Plasticity and Cognitive Function Across Human Lifespan

Review Outlines Blueberry Pomace Valorisation Strategies Across Food And Materials Sectors

Saudi Arabia Faces 16-Fold Clinical Trial Gap Despite Pharmaceutical Growth

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 89 other subscribers
  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.