• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Monday, November 16, 2026
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Biology

Device-Restricted Ankle Dorsiflexion Associated With Squat Mechanical Changes

by
November 16, 2026
in Biology
Reading Time: 3 mins read
0
Device-Restricted Ankle Dorsiflexion Associated With Squat Mechanical Changes

Device-Restricted Ankle Dorsiflexion Associated With Squat Mechanical Changes

Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

An experimental investigation by researchers at the School of Athletic Training at Guangzhou Sport University observed that a device-restricted ankle condition during high-load back squats was associated with lower knee flexion, lower peak knee and ankle joint moments, and greater trunk inclination.

Published in Frontiers in Bioengineering and Biotechnology, the study investigated how restricting ankle movement influences lower-body mechanics during heavy resistance exercise. The authors noted that although ankle dorsiflexion is known to affect lower-limb mechanics during squatting movements, its specific mechanical role during high-load resistance training has remained unclear. To evaluate this question, the research team compared sagittal-plane kinematics and kinetics between unrestricted and device-restricted ankle conditions and analyzed whether biomechanical responses differed between limbs.

The experiment enrolled eleven participants who completed both test conditions in a fixed-order within-subject design. During the squat sessions, participants lifted a high resistance load corresponding to 100 percent of their individual five-repetition maximum (5RM). In the restricted condition, an external restriction device was mechanically adjusted to limit dorsiflexion to a maximum angle of 10 degrees at each ankle joint.

To assess biomechanical performance, the investigators recorded three-dimensional kinematics and ground-reaction forces during the squat repetitions. Net internal joint moments at the ankle, knee, and hip joints were subsequently calculated using inverse dynamics to characterize lower-limb sagittal-plane joint loading across conditions.

The comparisons revealed several significant mechanical differences between the unrestricted and device-restricted squats. When squats were performed with the restriction device, participants exhibited lower knee flexion angles and greater forward trunk inclination. Kinetic measurements demonstrated lower peak net internal joint moment magnitudes at both the knee and ankle joints under the restricted condition. Furthermore, participants produced lower peak total vertical ground reaction force as well as lower limb-specific vertical ground reaction force at the instant of peak total vertical ground reaction force. Peak net internal hip joint moment magnitude, however, showed no statistically significant difference between the two conditions.

An exploratory finding emerged from the bilateral kinetic comparisons, where the researchers observed a statistically significant Condition by Side interaction for peak net internal knee joint moment magnitude. Despite this interaction, the authors pointed out that both limbs demonstrated lower peak knee joint moment values under the restricted condition.

Overall, the authors concluded that restricting ankle dorsiflexion to 10 degrees is associated with altered squat mechanics during high-load resistance exercise. Crucially, the researchers cautioned that the findings must not be interpreted as isolating a causal effect of ankle dorsiflexion restriction, citing key experimental limitations such as the fixed order of conditions and differences in footwear and device characteristics between the test conditions.

Their report was published as an open-access original research article in the Musculoskeletal, Movement and Assistive Biomechanics section of Frontiers in Bioengineering and Biotechnology under a Creative Commons Attribution license.

Subject of Research: Lower-limb biomechanics during high-load back squats with restricted ankle dorsiflexion

Article Title: Lower-limb biomechanics during high-load back squats with device-restricted ankle dorsiflexion

Article References: Chen, C., Tao, J., Lu, D., & He, J. (2026). Lower-limb biomechanics during high-load back squats with device-restricted ankle dorsiflexion. Frontiers in Bioengineering and Biotechnology, 14, 1979540. https://doi.org/10.3389/fbioe.2026.1979540

Image Credits: AI Generated

DOI: 10.3389/fbioe.2026.1979540

Keywords: ankle dorsiflexion, back squat, biomechanics, joint moments, resistance training, five-repetition maximum, sagittal-plane kinematics, ground-reaction forces, inverse dynamics, knee flexion, trunk inclination, knee joint moment, ankle joint moment, hip joint moment, vertical ground reaction force, bilateral asymmetry, Guangzhou Sport University

News Source: Gregory Coleman. (November 16, 2026). Device-Restricted Ankle Dorsiflexion Associated With Squat Mechanical Changes. Scienmag.

Tags: ankle dorsiflexionankle joint momentback squatbilateral asymmetryBiomechanicsfive-repetition maximumground reaction forcesGuangzhou Sport Universityhip joint momentinverse dynamicsjoint momentsknee flexionknee joint momentresistance trainingsagittal-plane kinematicstrunk inclinationvertical ground reaction force
Share12Tweet7Share2ShareShareShare1

Related Posts

EroMapper Plugin Enables Standardized Digital Mapping of Agricultural Soil Erosion

EroMapper Plugin Enables Standardized Digital Mapping of Agricultural Soil Erosion

November 16, 2026
Decellularized Silk Scaffolds Retain Mineral Matrix After 99 Percent Cell Removal

Decellularized Silk Scaffolds Retain Mineral Matrix After 99 Percent Cell Removal

November 16, 2026

Organoid Chip Models Require Functional Validation Beyond Structural Complexity

November 16, 2026

Emerald Ash Borer Infestation Triggers Divergent Root Bacterial Shifts in Ash

November 16, 2026

POPULAR NEWS

  • Emerald Ash Borer Infestation Triggers Divergent Root Bacterial Shifts in Ash

    Emerald Ash Borer Infestation Triggers Divergent Root Bacterial Shifts in Ash

    29 shares
    Share 12 Tweet 7
  • Lespedeza cyrtobotrya Stem Extracts Inhibit Monoamine Oxidase Enzymes In Vitro

    29 shares
    Share 12 Tweet 7
  • Sports Ethicists Urge Strict Limits on Performance Enhancing Swimming and Running Technologies

    29 shares
    Share 12 Tweet 7
  • Case Study Links Antipsychotic Drug Clozapine to Rare Colon Eosinophilic Cryptitis

    29 shares
    Share 12 Tweet 7

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

Language Models Classify Clinical Stroke Registry Free Text to Reveal Overlooked Complications

EroMapper Plugin Enables Standardized Digital Mapping of Agricultural Soil Erosion

Gelified Ethanol Demonstrates Feasible Hepatic Ablation in Preclinical Porcine Trials

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 89 other subscribers
  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.