• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Friday, August 29, 2025
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Health

A study reveals the need to review temperature control measures in hospitals to manage legionella

Bioengineer by Bioengineer
May 10, 2024
in Health
Reading Time: 3 mins read
0
Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

A work of the Clinical and Environmental Infectious Diseases Study Group (CEID) at Germans Trias i Pujol Research Institute (IGTP), led by Dr. Laura Gavaldà from the Bellvitge University Hospital, in collaboration with Institut Català d’Oncologia and Barcelona Public Health Agency, has disclosed significant findings on the survival of the Legionella pneumophila bacterium in hospital water systems.

Roger Cortés, Noemí Párraga and Laura Gavaldà, authors of the study.

Credit: IGTP

A work of the Clinical and Environmental Infectious Diseases Study Group (CEID) at Germans Trias i Pujol Research Institute (IGTP), led by Dr. Laura Gavaldà from the Bellvitge University Hospital, in collaboration with Institut Català d’Oncologia and Barcelona Public Health Agency, has disclosed significant findings on the survival of the Legionella pneumophila bacterium in hospital water systems.

Recently published in the journal Science of The Total Environment, the study suggests adjustments to control policies to effectively combat legionellosis. The study examined 80 isolates of Legionella pneumophila serogroup 6 from two independent hot water systems in a hospital, highlighting the genotypic variability and thermotolerance of the strains. By using flow cytometry to assess membrane integrity after exposing the bacteria to temperatures of 50°C, 55°C, and 60°C for 24 hours, it was found that a significant percentage of bacteria showed no growth on plate cultures, but remained in a viable but non-culturable (VBNC) state. Specifically, 52% of the bacteria at 50°C and 23% at 55°C retained their membrane integrity, while less than 5% did so at 60°C. These findings underscore the limitation of the plate culture method for detecting Legionella under thermal stress conditions.

Noemí Párraga, the first author of the study, emphasises: “The plate culture technique for Legionella control, required by Spanish legislation, underestimates the presence of this bacteria under stress factors, as it may remain in a viable but non-culturable state. This state can be reversed, recovering the microorganism’s infective capability.”

This study suggests the possibility of improving detection methods to ensure safe hospital environments, acknowledging that Legionella can withstand regulatory temperatures and remain in a viable but non-culturable state. It is advisable to consider this subpopulation in assessments, as it has the potential to become infectious.

“Increasing the temperature by 5˚C at the endpoints of hot water circuits could significantly reduce cases of legionellosis, especially in centres with a high presence of at-risk individuals,” points out Dr Gavaldà.


In 2022, the new Royal Decree 487/2022 was published in Spain, establishing the sanitary requirements for the prevention and control of legionellosis. This document sets out a series of measures for the prevention and control of Legionella in water installations. One of the defined measures is the temperature in hot and cold water circuits. A minimum temperature of 60°C is established in accumulators and 50°C at the endpoints (taps and showers) and on the return. The minimum required by the current royal decree are the microbiological controls through plate culture.


Dr Laura Gavaldà was a specialist in the Preventive Medicine and Hospital Hygiene Service at Bellvitge Hospital at the time of the study. She left the hospital a few months ago and is currently the head of the Tuberculosis Prevention and Control Service and Specific Programs at the Public Health Agency of Catalonia.



Journal

Science of The Total Environment

DOI

10.1016/j.scitotenv.2024.172410

Method of Research

Experimental study

Subject of Research

Cells

Article Title

Persistence of viable but nonculturable Legionella pneumophila state in hospital water systems: A hidden enemy?

Article Publication Date

1-Jun-2024

COI Statement

The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Share12Tweet8Share2ShareShareShare2

Related Posts

Dexamethasone’s Role in High-Altitude Illness Prevention

August 29, 2025

Chinese Nursing Graduates: Facing Clinical Transition Challenges

August 29, 2025

CellSpark: Ignite Electrophysiology Discovery Through Simulation

August 29, 2025

SAFeguard Study: Insulin Glargine’s Efficacy in Diabetes

August 29, 2025

POPULAR NEWS

  • blank

    Breakthrough in Computer Hardware Advances Solves Complex Optimization Challenges

    151 shares
    Share 60 Tweet 38
  • Molecules in Focus: Capturing the Timeless Dance of Particles

    142 shares
    Share 57 Tweet 36
  • New Drug Formulation Transforms Intravenous Treatments into Rapid Injections

    116 shares
    Share 46 Tweet 29
  • Neuropsychiatric Risks Linked to COVID-19 Revealed

    82 shares
    Share 33 Tweet 21

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

Dexamethasone’s Role in High-Altitude Illness Prevention

Chinese Nursing Graduates: Facing Clinical Transition Challenges

CellSpark: Ignite Electrophysiology Discovery Through Simulation

  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.