• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Thursday, July 24, 2025
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Health

French-German team refutes standard model of electroporation

Bioengineer by Bioengineer
March 9, 2023
in Health
Reading Time: 5 mins read
0
ADVERTISEMENT
Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

Strong electric fields can be used to create pores in biomembranes. The method is known as electroporation. Inducing such defects in membranes in a targeted manner is an important technique in medicine and biotechnology, but also in the treatment of foodstuffs. A French-German research group led by Dr. Carlos Marques from the Ecole Normale Supérieure in Lyon/France and Prof. Dr. Jan Behrends from the University of Freiburg’s Institute of Physiology has now collected data that casts fundamental doubt on what has been accepted for decades as the standard model of this mechanism. “This is a challenge for theory building and numerical simulations in this field,” says Marques. The results have now been published in the Proceedings of the Academy of Sciences of the United States of America (PNAS). They could help to improve the transport of active substances in cells.

French-German Team Refutes Standard Model of Electroporation

Credit: Carlos Marques, ENS Lyon

Strong electric fields can be used to create pores in biomembranes. The method is known as electroporation. Inducing such defects in membranes in a targeted manner is an important technique in medicine and biotechnology, but also in the treatment of foodstuffs. A French-German research group led by Dr. Carlos Marques from the Ecole Normale Supérieure in Lyon/France and Prof. Dr. Jan Behrends from the University of Freiburg’s Institute of Physiology has now collected data that casts fundamental doubt on what has been accepted for decades as the standard model of this mechanism. “This is a challenge for theory building and numerical simulations in this field,” says Marques. The results have now been published in the Proceedings of the Academy of Sciences of the United States of America (PNAS). They could help to improve the transport of active substances in cells.

Therapeutic substances enter cells through electropores

Direct current electric fields above a certain intensity disrupt the organization of lipids, fat-like molecules that form the basic structure of biological membranes in a bilayer, stacked together in a kind of liquid crystal. The resulting electropores, which are usually only stable for a very short time, allow water and solutes in the surrounding medium – such as drugs or other active substances, including RNA or DNA – to enter a cell.

Since the bilayer of lipids is very thin, measuring only five millionths of a millimeter, it is not necessary to apply very high voltages to generate very high field strengths (volts per meter). Thus, even at a voltage of 0.1 volt across the membrane, the field strength is 20 million volts per meter. In air, for example, spark discharge already occurs at three million volts per meter. However, it must be direct current voltage; alternating current fields in the megahertz-gigahertz range such as those generated by cell phones do not cause pores. While technique is well established, there is still a need to optimize electroporation of cell membranes for various purposes, such as to introduce genetic material for gene therapy. For this purpose, it is important to understand precisely the mechanism of pore formation under electric fields.

A standard model with little experimental verification

A standard theoretical model of electroporation from the 1970s assumes that the electric field applies pressure to the lipids, thereby increasing the probability of pore formation. So far, however, there is only little experimental verification of the model. This is due, first, to the difficulty of directly detecting the formation of electropores and, second, to the necessity of carrying out a very large number of such experiments in order to arrive at statistically tenable conclusions. This is because, in contrast to pores formed by proteins, electropores exhibit a very diverse, less stereotypical behavior.

A method that is capable of detecting the formation of pores with great accuracy and high time resolution is the electrical measurement of ionic current. Ions are positively or negatively charged constituents of the salts present in all biological fluids and, thus, inside and outside the cell. They are practically incapable of penetrating intact membranes, but as soon as a pore is opened, they are transported through it in the electric field. This transport of charged particles can be measured with highly sensitive amplifiers as a tiny electric current of a few billionths to millionths of an ampere. For this purpose, artificial lipid bilayers are created in thin Teflon layers via tiny openings of around 0.1 millimeter in diameter and placed between two electrodes. This technique of membrane formation is highly susceptible to failure – only one membrane is formed at a time, which breaks easily, especially during tests with higher voltages.

New method for creating lipid layers

For their experiments, the research group used a microchip with many openings, through which significantly more stable lipid layers can be generated very quickly and repeatedly using simplified procedures. This so-called microelectrode cavity array (MECA) was developed by Jan Behrends’s research group and has been produced and made commercially available by the Freiburg start-up company Ionera Technologies GmbH founded in 2014.

With the help of this device, it was now possible for the doctoral candidate Eulalie Lafarge from the Charles Sadron Institute at the University of Strasbourg and Dr. Ekaterina Zaitseva from the Freiburg research group to generate hundreds of membranes in a relatively short time and to measure and quantify pore formation as a function of the strength of the direct current field. The results demonstrated that, contrary to the prediction of the old standard model, the energy barrier for pore formation decreases not with the square of the field strength but proportionally to the field strength. In other words, doubling the field strength reduces the energy barrier only by half, not fourfold. This suggests a fundamentally different mechanism: a destabilization of the interface between lipid and water due to a reorientation of the water molecules in the electric field.

Oxidized membranes also studied

This result was also confirmed for membranes whose lipids were oxidized to varying degrees. This is interesting because lipid oxidation is a natural process in the regulation of cell membrane function and plays a role in the natural aging of the organism and possibly also in diseases such as Parkinson’s and Alzheimer’s. “Particularly in view of the medical significance of this topic, we want to pursue it further, also including optical methods, in order to reach a real understanding of this important phenomenon,” says Behrends.

 

Factsheet:

  • Original publication: Lafarge, E.J., Muller, P., Schroder, A.P., Zaitseva, E., Behrends, J.C., Marques, C. M.: Activation energy for pore opening in lipid membranes under an electric field. In: Proc. Natl. Acad. Sci. USA 120 (11) e2213112120. DOI: https://doi.org/10.1073/pnas.2213112120
  • Jan C. Behrends is professor of physiology at the University of Freiburg’s Faculty of Medicine. His research foci include single molecule detection and characterization of synthetic and natural polymers with nanopores as well as the development of methods for electrophysiology.
  • Eulalie Lafarge was supported by a scholarship from the Franco-German University (FGU).

 

Contact:
Annette Kollefrath-Persch
University and Science Communications
University of Freiburg
Tel.: 0761/203-8909
Email: annette.persch@pr.uni-freiburg.de



DOI

10.1073/pnas.2213112120

Share12Tweet8Share2ShareShareShare2

Related Posts

Single-Cell Atlas Links Chemokines to Type 2 Diabetes

July 20, 2025
blank

AI Diagnoses Structural Heart Disease via ECG

July 17, 2025

Functional Regimes Shape Soil Microbiome Response

July 17, 2025

Stealth Adaptations in Large Ichthyosaur Flippers

July 17, 2025

POPULAR NEWS

  • Blind to the Burn

    Overlooked Dangers: Debunking Common Myths About Skin Cancer Risk in the U.S.

    60 shares
    Share 24 Tweet 15
  • AI Achieves Breakthrough in Drug Discovery by Tackling the True Complexity of Aging

    70 shares
    Share 28 Tweet 18
  • USF Research Unveils AI Technology for Detecting Early PTSD Indicators in Youth Through Facial Analysis

    42 shares
    Share 17 Tweet 11
  • Dr. Miriam Merad Honored with French Knighthood for Groundbreaking Contributions to Science and Medicine

    46 shares
    Share 18 Tweet 12

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

Additive Manufacturing of Monolithic Gyroidal Solid Oxide Cells

Machine Learning Uncovers Sorghum’s Complex Mold Resistance

Pathology Multiplexing Revolutionizes Disease Mapping

  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.