HOUSTON – (July 14, 2022) – A strain-sensing smart skin developed at Rice University that uses very small structures, carbon nanotubes, to monitor and detect damage in large structures is ready for prime time.
Credit: Nagarajaiah and Weisman Research Groups/Rice University
HOUSTON – (July 14, 2022) – A strain-sensing smart skin developed at Rice University that uses very small structures, carbon nanotubes, to monitor and detect damage in large structures is ready for prime time.
The “strain paint” first revealed by Rice in 2012 uses the fluorescent properties of nanotubes to show when a surface has been deformed by stress.
Now developed as part of a non-contact optical monitoring system known as S4, the multilayered coating can be applied to large surfaces — bridges, buildings, ships and airplanes, for starters — where high strain poses an invisible threat.
The project led by Rice chemist Bruce Weisman, structural engineer Satish Nagarajaiah and lead author and graduate student Wei Meng springs from the 2002 discovery by Weisman that semiconducting carbon nanotubes fluoresce at near-infrared wavelengths. He subsequently developed optical instruments to explore the physical and chemical properties of nanotubes, including spectroscopic strain effects in 2008.
Independently in 2004, Nagarajaiah proposed and developed a non-contact optical strain sensor using carbon nanotube films bonded to structural members with epoxy and probed with Raman spectroscopy.
Their independent research paths merged into a common project in 2008 when Weisman and Nagarajaiah discovered that single-walled carbon nanotubes embedded in a polymer and bonded to a structural member will experience the same strain and can report it optically through spectral shifts in their near-infrared fluorescence. They reported that finding in a 2012 paper.
“Strain measurements are often made as part of safety-related inspections,” Weisman said. “That technical community is rightfully conservative, because their measurements must be reliable. So we need to overcome skepticism about new methods by proving that ours is as valid as the established ones.
“This paper presents our method’s credentials as a serious strain measurement technology,” he said.
Details of the next-generation, non-contact system appear in Nature’s Scientific Reports.
Strain mapping has relied on two technologies: physical gauges attached to structures and digital image correlation(DIC), used to compare images taken over time of surfaces with embedded “speckles.”
Weisman said S4 easily stands up to DIC. Better yet, the two techniques can work together. “We wanted to make a direct comparison to DIC, which is the only commercialized mapping method for strain out there,” he said. “It’s used in a number of industries, and people have a fairly high level of confidence in it.
“To demonstrate that our method can stand side by side with it and get results that are similar or better, Wei devised a method to incorporate S4 and DIC so both techniques can be used simultaneously and even complement each other,” Weisman said.
The skin itself has three layers, their configuration geared to the surface they cover. Typically, an opaque primer containing the DIC speckles is painted first. The second layer is a clear polyurethane that isolates the base from the nanotubes. Finally, the sensing layer of individually coated nanotubes, suspended in toluene, is sprayed on top. The toluene evaporates, leaving a sub-micron-thick sensing layer of nanotubes bonded to the structural member. An additional protective layer can be applied on top to keep the skin active for years.
The system also requires a reader, in this case a small visible laser to excite the nanotubes and a portable spectrometer to see how they’re strained.
Meng carefully compared S4 to both DIC and computer simulations in tests on I-shaped acrylic bars with a hole or a cutout, and on concrete blocks and aluminum plates with holes drilled into them to focus strain patterns. In every case, S4 gave a high-resolution, accurate view of the stressed specimens that was comparable to or better than the simultaneous DIC results.
Measuring concrete posed an optical challenge. “We found that cement in the concrete has intrinsic near-infrared emission that was interfering with our strain measurements,” Nagarajaiah said. “Wei spent an enormous amount of time, especially during the pandemic, carefully working on a new architecture to block those signals.”
Rather than the usual white base layer, a black base that also holds the speckles served the purpose, he said.
“There’s one additional advantage of S4 over DIC that we hadn’t appreciated until recently,” Weisman said. “That’s the fact that to get good results from DIC requires a high level of expertise on the part of the operator. Companies tell us that only their engineers are qualified to use it. It’s simple to take the data, but the interpretation requires a lot of judgment.
“Our method is quite different,” he said. “It’s nearly as easy to take the data, but the analysis to get the S4 strain map is automatic. In the long run that will be an advantage.”
“I have no doubt that this is a state-of-the-art strain-mapping method,” Nagarajaiah said. “We’ve tested it on structural members made of metals, plastics and concrete with complex micro-cracks and subsurface damage, and it works in all cases. I believe we’ve reached the stage where it’s ready for implementation, and we are engaging with industry to learn how it can help them.”
Rice research scientist Sergei Bachilo and graduate student Ashish Pal are co-authors of the study. Weisman is a professor of chemistry and of materials science and nanoengineering. Nagarajaiah is a professor of civil and environmental engineering, of materials science and nanoengineering and of mechanical engineering.
The Office of Naval Research (N00014-14-1-0013) and the National Science Foundation (1803066) supported the research.
-30-
Read the abstract at https://www.nature.com/articles/s41598-022-15332-1.
This news release can be found online at https://news.rice.edu/news/2022/strain-sensing-smart-skin-ready-deploy.
Follow Rice News and Media Relations via Twitter @RiceUNews.
Related materials:
‘Smart skin’ simplifies spotting strain in structures: https://news2.rice.edu/2018/11/15/smart-skin-simplifies-spotting-strain-in-structures-2/
Nano-infused paint can detect strain: https://news2.rice.edu/2012/06/21/nano-infused-paint-can-detect-strain-2/
Weisman Research Group: http://weisman.rice.edu/index
Nagarajaiah Group: http://satishnagarajaiah.rice.edu
Wiess School of Natural Sciences: https://naturalsciences.rice.edu
George R. Brown School of Engineering: https://engineering.rice.edu
Video:
Video produced by Brandon Martin/Rice University
Images for download:
https://news-network.rice.edu/news/files/2022/07/0718_STRAIN-1-WEB.jpg
A three-layer smart skin on a structure can detect strain through the fluorescence of embedded carbon nanotubes, according to its inventors at Rice University. The skin can be painted or sprayed on buildings, bridges, aircraft and ships to provide a non-contact way to monitor the structural health of a structure. (Credit: Nagarajaiah and Weisman Research Groups/Rice University)
https://news-network.rice.edu/news/files/2022/07/0718_STRAIN-2-WEB.jpg
A Rice University lab tests material covered in strain-sensing smart skin. The multilayer coating contains carbon nanotubes that fluoresce when under strain, matching the strain experienced by the material underneath. (Credit: Jeff Fitlow/Rice University)
https://news-network.rice.edu/news/files/2022/07/0718_STRAIN-3-WEB.jpg
Graduate student Wei Meng works at a test rig at a Rice University lab, validating measurements of strain in a variety of materials with strain-sensing smart skin. (Credit: Jeff Fitlow/Rice University)
https://news-network.rice.edu/news/files/2022/07/0718_STRAIN-4-WEB.jpg
Rice University researchers Wei Meng (seated), Sergei Bachilo (left) and Bruce Weisman developed strain-sensing smart skin based on Weisman’s pioneering discovery of fluorescence in carbon nanotubes. They worked with Rice structural engineer Satish Nagarajaiah to develop the non-contact method to efficiently measure strain in large structures. (Credit: Jeff Fitlow/Rice University)
https://news-network.rice.edu/news/files/2022/07/0718_STRAIN-5-WEB.jpg
A comparison of measurements on an acrylic under strain shows Rice University’s S4 system, left, gives a more detailed readout than standard digital image correlation (DIC) at right. (Credit: Weisman Lab/Nagarajaiah Lab/Rice University)
Located on a 300-acre forested campus in Houston, Rice University is consistently ranked among the nation’s top 20 universities by U.S. News & World Report. Rice has highly respected schools of Architecture, Business, Continuing Studies, Engineering, Humanities, Music, Natural Sciences and Social Sciences and is home to the Baker Institute for Public Policy. With 4,240 undergraduates and 3,972 graduate students, Rice’s undergraduate student-to-faculty ratio is just under 6-to-1. Its residential college system builds close-knit communities and lifelong friendships, just one reason why Rice is ranked No. 1 for lots of race/class interaction and No. 1 for quality of life by the Princeton Review. Rice is also rated as a best value among private universities by Kiplinger’s Personal Finance.
Journal
Scientific Reports
DOI
10.1038/s41598-022-15332-1
Method of Research
Experimental study
Subject of Research
Not applicable
Article Title
Next-generation 2D optical strain mapping with strain-sensing smart skin compared to digital image correlation
Article Publication Date
3-Jul-2022
COI Statement
The authors declare no competing interests.