• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Thursday, March 26, 2026
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Health

A test of a customized implant for hip replacement

Bioengineer by Bioengineer
December 13, 2019
in Health
Reading Time: 3 mins read
0
IMAGE
Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

Scientists developed a mathematical model of an ‘endoprosthesis-skeleton’ system; special attention was paid to the geometry and internal structure of hip bones

IMAGE

Credit: Peter the Great St.Petersburg Polytechnic University


A team of scientists from the Advanced Manufacturing Technologies Center of the National Technology Initiative (NTI) of Peter the Great St.Petersburg Polytechnic University (SPbPU) (head — Prof. A.I. Borovkov, the Vice-rector for Advanced Projects of Peter the Great St. Petersburg Polytechnic University) developed a mathematical model of an “endoprosthesis-skeleton” system. Special attention was paid to the geometry and internal structure of hip bones. Using advanced computer modeling technologies, the team assessed the integrity of the biomechanical structure for a typical case (a patient standing on two legs). Currently the team is working on a methodology that would reduce the time of such analysis to several days. The results of the study were published in the Vibroengineering PROCEDIA journal and presented at the 12th All-Russia Congress on Fundamental Issues of Theoretical and Applied Mechanics.

Hip joint arthroplasty is a relatively common procedure today. During arthroplasty the upper part of a patient’s hip bone is replaced with a metal stem with a spherical joint element, and a cup to allow the head of the joint to rotate inside the pelvis. Medical companies manufacture standard elements with different parameters for ordinary hip replacement operations. However, after some time a certain share of patients experiences issues with implants and requires their replacement. As a rule, this happens due to the insufficient (or excessive) load the endoprosthesis puts on the hip bone causing its tissue to change. Moreover, bone strength can be affected by osteoporosis and other diseases. By the time of the second surgery (the removal of the initial implant and the installation of a revision one) a part of the hip bone becomes unfit as it is unable to bear the load. Therefore, when a patient comes to a secondary operation with a damaged hip bone, standard implants are of no use for them, and a regular cup (even if it is of a bigger size) might not work.

The manufacturers produce special sets of elements that can be combined with each other in different ways to be used in revision operations as well as in patients with compound fractures or cancer. However, such surgeries have high risk rates: any issue with a revision structure or additional bone tissue loss may cause grave health issues. It is extremely important to understand if the prosthesis is able to bear the load, and if the damage to the patient’s bone can be avoided. Virtual testing before installation could help eliminate numerous post-surgical complications. However, there is currently no universal assessment method to do so. It takes a long time to build a model on the basis of bone CT results, while the patient’s health parameters keep constantly changing. Therefore, the window between diagnostics and the surgery should be as short as possible.

A team of engineers from the Advanced Manufacturing Technologies Center of the National Technology Initiative (NTI) of Peter the Great St. Petersburg Polytechnic University (SPbPU) analyzed the integrity of an “endoprosthesis-skeleton” system for a case of hip joint revision arthroplasty and assessed the durability of the implanted structure and pelvis bones, as well as the distribution of load when a patient stands on two feet. The work describes the peculiarities of simulation model preparation. Currently, this process takes a long time, but the team is working on a method to reduce the whole calculation to several days.

Other groups tend to entirely ignore pelvic bones in their studies or to consider only their simplified models. However, in this case the researchers paid special attention to detailed description of pelvic bones including their external and porous internal layers. This was done due to the fact that the pelvis is often at risk in its entirety.

“If we consider the work done by us as a virtual test, the article described the load we put on the patient’s skeleton and the implant, as if they were tested in reality. Studies like this help reduce the risk of complications in patients with individually designed implants. Hopefully, they would help prioritize prevention over cure,” commented Mikhail Zhmaylo, a lead engineer at the Advanced Manufacturing Technologies Center of the National Technology Initiative (NTI) of Peter the Great St. Petersburg Polytechnic University (SPbPU)

###

Among active participants of the study were graduate students of the “Dynamics and Integrity of Complex Mechanical Systems” program supervised by L.B. Maslov, the Head of the Department of Theoretical and Applied Mechanics of Ivanovo State Energy University, as well as medical practitioners from Vreden Russian Science and Research Institute of Traumatology and Orthopedics.

Media Contact
Raisa Bestugina
[email protected]
7-812-591-6675

Related Journal Article

http://dx.doi.org/10.21595/vp.2019.20961

Tags: DiagnosticsNanotechnology/MicromachinesPublic HealthResearch/DevelopmentSoftware EngineeringSurgeryTechnology/Engineering/Computer ScienceTelecommunicationsTransplantationTrauma/Injury
Share12Tweet8Share2ShareShareShare2

Related Posts

Aversive Learning Hijacks Brain Sugar Sensor

March 25, 2026

Can Psychosocial Factors Influence Cancer Risk?

March 23, 2026

Depression Factors in Elderly: Pre vs. Post-COVID Analysis

March 23, 2026

Hidden Health Crises Among US and UK Volunteers in Ukraine Uncovered in New Study

March 23, 2026
Please login to join discussion

POPULAR NEWS

  • blank

    Revolutionary AI Model Enhances Precision in Detecting Food Contamination

    96 shares
    Share 38 Tweet 24
  • Imagine a Social Media Feed That Challenges Your Views Instead of Reinforcing Them

    1003 shares
    Share 397 Tweet 248
  • Uncovering Functions of Cavernous Malformation Proteins in Organoids

    54 shares
    Share 22 Tweet 14
  • Promising Outcomes from First Clinical Trials of Gene Regulation in Epilepsy

    51 shares
    Share 20 Tweet 13

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

In-Sensor Cryptography Links Physical Process to Digital Identity

Can Psychosocial Factors Influence Cancer Risk?

Depression Factors in Elderly: Pre vs. Post-COVID Analysis

Subscribe to Blog via Email

Success! An email was just sent to confirm your subscription. Please find the email now and click 'Confirm' to start subscribing.

Join 78 other subscribers
  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.