A research team has designed and demonstrated a benchtop optically emulated computed tomography scanner that relies on visible light rather than ionizing radiation to reconstruct the internal structures of semi-transparent specimens. Traditional clinical and industrial computed tomography systems depend heavily on penetrating X-rays, which necessitate substantial capital investment, heavy lead shielding infrastructure, trained technical operators, and rigorous regulatory compliance. These operational and safety constraints have historically prevented schools, undergraduate laboratories, and low-resource academic settings from providing students with direct, hands-on experience in tomographic data collection and volume reconstruction. To overcome these institutional barriers, investigators engineered an open, accessible imaging platform that substitutes hazardous radiation with an energy-efficient light-emitting diode backlight, allowing learners to safely inspect specimens and explore cross-sectional imaging principles in open classroom spaces.
The physical architecture of the optical scanner is organized into four modular, decoupled subsystems comprising a light box enclosure, a motorized rotating stage mechanism, an optical acquisition unit, and embedded control circuitry. The outer housing was custom-built from rigid plywood sheets selected for structural stability, affordability, and ease of mechanical modification. To suppress internal optical reflections and isolate the optical path from ambient classroom lighting, all internal surfaces of the enclosure were coated with a matte black finish. Strategically cut side apertures accommodate external wiring, physical operation switches, and the camera lens. Inside the box, a vertical midwall supports a compact battery-operated Milwaukee light-emitting diode light bar measuring 12 centimeters by 2.5 centimeters by 2.5 centimeters, held securely by integrated magnetic fixtures. A square-frame optical diffuser positioned immediately downstream of the light bar scatters the light evenly across the sample area, eliminating severe shadows and creating a uniform backlight field critical for transmission measurements.
To simplify mechanical motion and avoid rotating heavy diagnostic equipment around an object, the scanner keeps the illumination source and detector stationary while rotating the specimen on a motorized turntable. The stage platform and dedicated motor bracket were fabricated from polylactic acid thermoplastic using fused deposition modeling three-dimensional printing, followed by light sanding and drilling to align securely with the drive shaft of a stepper motor. To mitigate movement artifacts and prevent specimen slippage during incremental rotations, a thin friction layer composed of a paper towel strip is placed beneath the sample mounting base. The sample itself, such as a thin lemon cross-section mounted upright on a cork platform using a slender pin or toothpick, sits precisely centered in front of the diffused light source. This geometry ensures that the object remains within the optical axis throughout a complete revolution, preserving axial symmetry across projection datasets.
Image capture is performed using an external consumer-grade Nikon D5600 digital single-lens reflex camera equipped with an Advanced Photo System type-C sensor and a 50-millimeter f/1.8 prime lens. The optical assembly is secured to the exterior wall of the light box by a stabilizing frame constructed from polyvinyl chloride piping and three-dimensional printed polylactic acid connectors engineered in Siemens NX. The camera is aligned through a dedicated circular port so that its optical axis intersects the rotational center of the specimen stage at right angles. The prime lens provides a wide physical aperture that captures adequate transmission signals under low illumination levels while maintaining low geometric distortion and edge sharpness. The camera operates in Program mode with manual focus locked and live view disabled to conserve battery power, utilizing an automated interval timer to record single exposures every second across the scanning session.
Mechanical rotation and data capture coordination are governed by an electronic circuit built on a solderless breadboard and powered via a universal serial bus link to an external computer. At the core of the electronics is a Teensy 2.0 microcontroller board, chosen for its small physical footprint and compatibility with standard Arduino software libraries. The microcontroller directs pulse timing and directional signaling to an adjacent stepper motor driver module fitted with an aluminum heat sink to dissipate thermal loads during sustained scanning sequences. A dedicated external toggle switch on the chassis allows manual on-off power control over the motor circuit. Stepper actuation enables discrete, repeatable angular displacement without the complexity of closed-loop optical encoders, ensuring that projection frames correspond to evenly spaced angular intervals spanning an entire 360-degree rotation.
The standard scanning protocol entails preparing a semi-transparent sample, such as a five-to-eight millimeter thick lemon slice, centering it upon the stage, and closing the light-tight lid of the enclosure. The operator flips the manual power toggle to start the stepper motor rotation and immediately activates the camera interval timer to begin synchronized acquisition. Across a complete 200-second scanning run, the camera captures exactly 200 sequential projection images as the stage completes a continuous 360-degree rotation. Once the scan finishes, the operator switches off the motor circuit to prevent motor overheating and transfers the image files from the digital memory card to a computer workstation. Batch processing utilities are then employed to order the files numerically, crop extraneous background pixels around the rotating object, and standardize image resolution to prevent excessive memory consumption during numerical processing.
The computational reconstruction pipeline executes inside MATLAB, taking advantage of matrix operations and tomographic filtering algorithms. For each preprocessed projection image, the system converts pixel values to grayscale and extracts a single, fixed central vertical column corresponding to light attenuation along that line of sight. By stacking these 200 one-dimensional profiles horizontally in chronological order, the software constructs a two-dimensional sinogram matrix that documents the specimen’s light attenuation across rotation angles. High-density structures like outer rinds and dense seeds attenuate more transmitted light, appearing as consistent, high-contrast traces across the sinogram, while translucent pulp sections exhibit smoother and lower attenuation trajectories.
Two-dimensional cross-sectional slices are reconstructed from the sinogram matrix by applying the inverse Radon transform via the filtered backprojection algorithm implemented in MATLAB’s iradon function. The calculation utilizes a Ram-Lak filter to suppress low-frequency blurring artifacts while sharpening anatomical boundaries over angles evenly spaced between zero and 180 degrees. In the reconstructed grayscale slices, darker pixel values correspond mathematically to areas of higher optical attenuation that blocked incoming illumination. When applied to experimental lemon slice scans, the reconstruction distinctly delineated the dense outer peel as an attenuating ring, resolved internal pulp compartments, and located compact seeds positioned near the center of the fruit.
To quantitatively evaluate the contrast fidelity of the resulting tomograms, investigators carried out a region-of-interest analysis across the reconstructed cross-sections. Manually selected regions within the specimen showed that the outer peel exhibited a mean grayscale intensity of 0.99 with a standard deviation of 0.02 arbitrary units. In contrast, the internal seed structures registered a mean intensity of 0.71 with a standard deviation of 0.04 arbitrary units. The measured contrast difference of 0.28 arbitrary units between the peel and seeds proved statistically significant with a P-value of less than 0.001. This metric confirmed the system’s capacity to discriminate between distinct internal tissues based on differential optical attenuation, despite subtle contrast variations in visible-light projection photography.
For three-dimensional volumetric interpretation, the calculated cross-sectional slices were loaded into the open-source Vol3D toolbox in MATLAB, which employs graphics processing unit acceleration to render three-dimensional volumes interactively. Within this digital rendering environment, users can adjust opacity thresholds, reposition virtual lighting angles, and slice through coordinate planes to examine spatial relationships among anatomical compartments. The resulting volume model highlighted the outer rind with substantial opacity to delineate surface boundaries, retained semi-transparency across internal pulp segments to reveal underlying depth, and rendered the dense seeds as distinct inclusions suspended within the fruit matrix, offering intuitive visualization for students studying spatial geometries.
In evaluating the system relative to previous optical CT configurations, the authors noted key performance trade-offs. Earlier platforms developed by researchers such as Zakariaee or Stavroulakis focused on high-precision radiation dosimetry or industrial container inspection, often requiring laser sources, photodiode detectors, or index-matching fluid baths. In contrast, the current setup achieves a spatial resolution between 0.1 and 0.2 millimeters and an overall acquisition time of 200 seconds while utilizing consumer-grade photography equipment and open-source code. When contrasted with the educational prototype by Lim and colleagues, this system demonstrates an integrated, reproducible pipeline linking motorized breadboard control directly to interactive three-dimensional volumetric visualization.
The authors identified several practical limitations inherent to visible-light transmission scanning. Because the technique relies entirely on photons penetrating through the sample, it is strictly restricted to translucent or semi-transparent materials, rendering opaque biological tissues and whole fruits unsuitable due to high scattering and light absorption. Additionally, surface refraction at curved specimen interfaces creates bright edge artifacts that conventional optical systems suppress using fluid immersion. The current workflow also involves manual steps for sample centering, motor switching, and image formatting, while mathematical backprojection emulates depth slices without true axial physical sectioning. Future enhancements proposed by the team include automated shutter-motor synchronization, precision clamp fixtures, graphical software interfaces, and the introduction of collimated laser backlighting to more accurately represent mathematical line integrals.
Subject of Research: Design and evaluation of an optically emulated computed tomography scanner for educational environments
Article Title: Development of an optically emulated computed tomography scanner for college education
Article References: Hossen Manik, M. M., Muldowney, W., Islam, M. Z., & Wang, G. (2026). Development of an optically emulated computed tomography scanner for college education. Visual Computing for Industry, Biomedicine, and Art, 9(1), Article 2. https://doi.org/10.1186/s42492-025-00211-z
Image Credits: AI Generated
DOI: 10.1186/s42492-025-00211-z
Keywords: computed tomography, optical tomography, inverse Radon transform, visible light imaging, educational technology, filtered backprojection, Vol3D, Teensy 2.0, DSLR imaging, sinogram, specimen scanning, 3D volume rendering, optical attenuation, stepper motor, laboratory education, non-ionizing imaging, Ram-Lak filter
News Source: Drew Townsend. (November 28, 2026). Desktop Optical CT Scanner Emulates Tomographic Imaging Using Visible Light and Citrus. Scienmag.