• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Thursday, November 26, 2026
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Health

Higher Heart Rate Variability Reduces Coronary Computed Tomography Angiography Image Interpretability

by
November 26, 2026
in Health
Reading Time: 2 mins read
0
Higher Heart Rate Variability Reduces Coronary Computed Tomography Angiography Image Interpretability

Higher Heart Rate Variability Reduces Coronary Computed Tomography Angiography Image Interpretability

Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

Increased heart rate variability significantly impairs subjective image quality and diagnostic interpretability during coronary computed tomography angiography, according to a retrospective clinical evaluation of 2,692 patients published in BMC Cardiovascular Disorders. The research team assessed scans conducted for individuals presenting with chest pain to determine how fluctuations in cardiac rhythm affect arterial visualization across stable heart rate intervals.

The primary objective of the investigation focused on evaluating the precise heart rate variability cut-off thresholds at which computed tomography image quality deteriorates within identical heart rate ranges. Researchers also sought to identify the specific coronary arterial segments most susceptible to motion distortion and to establish whether elevated variability systematically compromises diagnostic image interpretability under controlled scanning conditions.

The study analyzed a cohort of 2,692 patients who underwent coronary computed tomography angiography for chest pain between January and December 2024. All participants included in the final retrospective assessment successfully maintained complete breath-hold and exhibited no bodily movement throughout the active scanning sequence, eliminating gross respiration and patient motion as confounding factors during data acquisition.

Image quality was evaluated using a standardized 4-point Likert scale, categorizing visualizations from score 1 for non-diagnostic quality to score 4 for excellent quality. Investigators applied Youden’s Index to determine optimal heart rate cut-offs corresponding to excellent, good, and poor image quality under sinus rhythm, while also identifying specific heart rate variability cut-offs within matching heart rate tiers to define comparative patient subgroups.

Analysis of objective image quality metrics demonstrated no statistically significant differences across the established subgroups, with all objective comparisons yielding P values greater than 0.05. However, subjective image quality scores declined significantly as heart rate variability increased within each fixed heart rate category, with all comparative evaluations demonstrating consistent statistical significance across the analyzed patient cohorts.

The degradation of image quality selectively impacted particular regions of the coronary tree, as non-diagnostic arterial segments were predominantly located within the distal coronary arteries and small arterial branches. Within each stratified heart rate group, the total proportion of diagnostic segments receiving Likert scores between 2 and 4 decreased significantly as heart rate variability escalated.

The authors concluded that cardiac motion artefacts multiply as heart rate variability rises within any given heart rate boundary, though the exact threshold for quality deterioration varies across different rate strata. Furthermore, at equivalent variability levels, higher absolute heart rates correlated with aggravated motion artefacts, demonstrating that elevated heart rates require lower variability to maintain comparable image interpretability.

Subject of Research: Impact of heart rate variability on coronary computed tomography angiography image quality and segment interpretability

Article Title: Heart rate variability: affected segments, cut‑off, and image interpretability

Article References: Nan, N., Mei, J., Yang, L., Ge, L., Zhu, J., Zhu, Y., Zhou, D., & Ma, H. (2026). Heart rate variability: affected segments, cut‑off, and image interpretability. BMC Cardiovascular Disorders. https://doi.org/10.1186/s12872-026-07046-3

Image Credits: AI Generated

DOI: 10.1186/s12872-026-07046-3

Keywords: coronary computed tomography angiography, heart rate variability, image interpretability, motion artefacts, coronary arteries, chest pain, Likert scale, Youden index, sinus rhythm, distal coronary arteries, cardiac imaging, retrospective analysis, arterial segments, objective image quality, subjective image quality, heart rate thresholds

News Source: Ophelia Keating. (November 26, 2026). Higher Heart Rate Variability Reduces Coronary Computed Tomography Angiography Image Interpretability. Scienmag.

Tags: arterial segmentscardiac imagingchest paincoronary arteriescoronary computed tomography angiographydistal coronary arteriesheart rate thresholdsheart rate variabilityimage interpretabilityLikert scalemotion artefactsobjective image qualityretrospective analysissinus rhythmsubjective image qualityYouden index
Share12Tweet7Share2ShareShareShare1

Related Posts

Grandmaternal Air Pollution Exposure Linked to Preterm Birth Across Three Generations

Grandmaternal Air Pollution Exposure Linked to Preterm Birth Across Three Generations

November 26, 2026
Fruit Fly Lifespan Extension by Lithocholic Acid Requires AlaRS Protein Modification

Fruit Fly Lifespan Extension by Lithocholic Acid Requires AlaRS Protein Modification

November 26, 2026

Dual-Tracer PET/CT Enhances Localization and Accuracy for Suspected Insulinoma

November 26, 2026

Island Soil Streptomyces Yields Novel Phenazinone Antibiotic With Varying Prenyl Chains

November 26, 2026

POPULAR NEWS

  • Many Australian Parents Struggle With Cot-Only Infant Sleep Guidelines

    Many Australian Parents Struggle With Cot-Only Infant Sleep Guidelines

    29 shares
    Share 12 Tweet 7
  • Trauma-Focused Cognitive Behavioral Therapy Reduces Trauma Symptoms in Young Georgian Children

    29 shares
    Share 12 Tweet 7
  • Tissue Stiffening Drives Histone Serotonylation to Prime Embryonic Cell Migration in Vivo

    29 shares
    Share 12 Tweet 7
  • Amaranthus Cruentus Demonstrates Resilient Physiological Adaptations Under Drought and Salinity Stresses

    29 shares
    Share 12 Tweet 7

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

Specific Ancient Viral Sequences Reactivate Across Viral Hepatitis Driven Liver Tumors

Boosting Agricultural Methanotrophic Microbes Could Abate Over 1.5 Gigatonnes of Methane

Genomic Study Reveals Convergent Evolution of White Elytra in Namib Darkling Beetles

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 89 other subscribers
  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.