In an experimental investigation evaluating power electronics regulation, an engineering researcher has demonstrated that a fractional-order proportional-integral-derivative controller tuned through a serial hybrid metaheuristic algorithm achieves superior dynamic stability and error minimization in a continuous-conduction-mode step-up direct-current converter. Published in the Arabian Journal for Science and Engineering, the study developed and validated a controller architecture that integrates particle swarm optimization with the artificial bee colony algorithm to overcome the labor-intensive challenge of tuning fractional-order controllers. Modern switched-mode power supplies, such as non-isolated boost converters, are extensively utilized in renewable energy systems and battery charging units, yet they present challenging non-minimum phase system characteristics alongside nonlinear switching dynamics. When operating under continuous conduction mode, source voltage fluctuations and load resistance variations shift the operating point of the circuit. While fractional-order proportional-integral-derivative controllers provide two additional degrees of freedom compared to classical three-parameter integer-order implementations, establishing the optimal balance among all five parameters has historically posed significant computational hurdles.
To establish a rigorous mathematical foundation for the control system, the study derived an analytical model of the step-up direct-current converter accounting for parasitic resistances across all components. The physical circuit architecture incorporates a power switch, an energy-storage inductor with equivalent series resistance, a diode with threshold voltage and internal resistance, and an output filter capacitor with equivalent series resistance driving a resistive load. State-space representations were formulated for both switching intervals, describing the rate of change of inductor current and capacitor voltage when the switch is closed and when the switch is open. By combining these switched operational states using the duty ratio within an average modeling approach, the author formulated a unified average system model. Applying small-signal perturbation approximations, where variables are decomposed into their direct-current steady-state components and dynamic small-signal components, yielded a second-order linear state-space representation. From this formulation, a single-input single-output transfer function was established, confirming the non-minimum phase characteristics of the voltage feedback boost converter with right-half-plane zero dynamics.
Addressing the inherent complexity of fractional calculus in closed-loop systems, the study structured the control law around non-integer integration and differentiation operators. Mathematical foundations of fractional calculus typically rely on either the Grünwald-Letnikov definition, which expresses non-integer derivatives through infinite series limits, or the Riemann-Liouville formulation, which incorporates convolution integrals bounded by the Gamma function. In the Laplace transform domain under assumed zero initial conditions, fractional differential operations of non-integer order simplify to an s-domain operator raised to an arbitrary real power. The fractional-order proportional-integral-derivative controller transfer function was consequently formulated with five distinct parameters: proportional gain, integral gain, derivative gain, fractional integration order lambda, and fractional differentiation order mu. Because continuous fractional-order operators inherently maintain infinite memory of prior states, direct digital implementation is impractical; therefore, the study utilized Oustaloup’s recursive filter approximation within a specified frequency band to generate high-order rational transfer functions, which were then decomposed into partial fraction expansions to eliminate numerical instability arising from large polynomial coefficients.
The central optimization challenge was addressed by formulating a serial hybrid optimization strategy that couples particle swarm optimization with the artificial bee colony framework. Classical particle swarm optimization models the collective navigation of bird flocks, updating particle velocities and spatial coordinates using cognitive memory components and social swarm information. Although particle swarm optimization converges rapidly, it suffers from susceptibility to stagnation and premature trapping in local optima. Conversely, the artificial bee colony algorithm simulates the foraging dynamics of honeybees, employing employed bees to explore local nectar patches, onlooker bees to allocate search effort through roulette-wheel selection based on relative fitness values, and scout bees to perform spontaneous global exploration when sources become exhausted. While artificial bee colony routines exhibit robust global search capabilities and reliably escape local minima, their convergence speed is inherently slow. By linking both algorithms consecutively into a serial structure, the author leveraged the initial high-speed convergence of the swarm mechanics alongside the thorough refinement and local optima avoidance of the colony mechanism.
To evaluate parameter search efficiency, six distinct fractional-order controllers were developed across different combinations of metaheuristic algorithms and objective cost functions. Two controllers were optimized using standalone particle swarm optimization, two were tuned via the artificial bee colony algorithm, and two were produced by the hybrid optimization pipeline. Each optimization methodology was tested against both the Integral of Absolute Error and the Integral of Squared Error cost functions over dynamic training scenarios where input voltages ranged between 6.5 volts and 13.5 volts and load resistances spanned from 10 ohms to 95 ohms. To ensure a balanced and fair comparison, population sizes and iteration counts were systematically standardized: the particle swarm size was fixed at 30 particles with acceleration constants set to 0.67, while the artificial bee colony employed 30 employed bees, 30 onlooker bees, and an abandonment limit of 25 over a strict cap of 30 total iteration epochs. For benchmark comparison, an integer-order proportional-integral controller was simultaneously synthesized through frequency-domain analysis, achieving a phase margin of 94.2 degrees at 102 radians per second.
Following optimization, the synthesized controllers were translated into discrete-time formats suitable for implementation on digital signal processing hardware. The rational continuous transfer functions derived from Oustaloup approximations were expanded into sixth-order partial fractions, and the Backward Euler transformation was applied at an 8-kilohertz sampling frequency. Bode frequency response analyses verified that the partial fraction decomposition and discrete approximations maintained harmonic alignment with theoretical frequency curves across a wide bandwidth, preventing any distortion or performance degradation. Simulation experiments were subsequently executed in Matlab utilizing a simulation time step of 100 nanoseconds, a control loop execution interval of 125 microseconds, and injected output voltage white noise with a variance of 4.47 multiplied by 10 to the negative fifth power to emulate physical measurement disturbances. The simulation evaluated transient performance under a complex twelve-stage disturbance sequence encompassing abrupt source voltage transitions and substantial load resistance shifts.
The simulation results demonstrated that all fractional-order controller variants successfully maintained continuous conduction mode operation and regulated output voltage to the 20-volt setpoint, outperforming the benchmark proportional-integral controller. Across twelve operational stages, twenty-five separate performance indices—including settling time, percentage overshoot, and mean squared error—were tracked. The fractional controller tuned via the artificial bee colony algorithm under the Integral of Squared Error criterion secured the top ranking in ten of the twenty-five metrics, while the hybrid-tuned counterpart operating under the same error criterion secured first place in nine metrics. Notable transient enhancements included a 49.4 percent reduction in output voltage overshoot achieved by the hybrid Integral of Squared Error controller relative to the classical proportional-integral baseline during Stage-3 disturbance conditions.
The hardware apparatus comprised a programmable direct-current voltage source modulated by an analog programming circuit, the prototype boost converter with component parameters pre-measured via an LCR meter, dual resistive load banks configured at 10 ohms and 83 ohms switched via relay circuits, MOSFET gate drive circuitry, current sensors, and digital oscilloscopes. Data acquisition channels captured source voltage, output current, output voltage, and duty cycle control signals at a 2-kilohertz sampling rate, while inductor current was sampled at 32 kilohertz to capture high-frequency current ripple across the 16-kilohertz power switching cycle. Across the entire 2.1-second physical test schedule, duty ratio outputs remained bounded within the legitimate operational range between zero and unity without encountering control saturation.
Experimental outcomes demonstrated that the hybrid-optimized fractional-order controller using the Integral of Squared Error criterion outperformed all other designs, securing the most favorable scores across eight of twenty-three calculated experimental indices. In terms of percentage overshoot, the hybrid design achieved the best result in three operational stages and second best in two stages, while also ranking first or second in settling time across seven of the twelve stages. Discrepancies observed between numerical simulations and laboratory measurements were attributed to inductor magnetic saturation during high-current low-voltage stages, parasitic parameter estimation limits, and lower hardware signal sampling rates relative to simulation models. Specifically, during experimental Stages 2, 9, and 11, low input voltage combined with high current demands drove the inductor core into magnetic saturation, illustrating hardware boundary constraints.
The author noted that while the standalone artificial bee colony algorithm exhibited slightly lower final cost function values during numerical training epochs, the hybrid algorithm yielded superior empirical control when deployed on real hardware. This divergence occurred because conventional time-integral error metrics omit explicit penalties for transient overshoot and settling duration during offline optimization. The research verified that serial hybridization successfully mitigates premature convergence and local minima stagnation within a constrained budget of only thirty iteration epochs, validating the practical viability of fractional-order control for high-speed switched-mode power supplies. Future investigations are planned to explore alternative metaheuristic frameworks, higher iteration counts, and modified objective cost functions that directly incorporate settling time and overshoot criteria into the parameter optimization routine.
Subject of Research: Fractional-order PID controller optimization for boost converters using hybrid metaheuristics
Article Title: The Fractional-Order Proportional-Integral-Derivative Controller Tuned with Hybrid Particle Swarm Optimization-Artificial Bee Colony Algorithm for Boost Converters: An Experimental Study
Article References: Aliskan, I. (2026). The Fractional-Order Proportional-Integral-Derivative Controller Tuned with Hybrid Particle Swarm Optimization-Artificial Bee Colony Algorithm for Boost Converters: An Experimental Study. Arabian Journal for Science and Engineering, 51(16), 19601-19618. https://doi.org/10.1007/s13369-026-11423-7
Image Credits: AI Generated
DOI: 10.1007/s13369-026-11423-7
Keywords: boost converter, fractional-order PID, particle swarm optimization, artificial bee colony, hybrid optimization, continuous conduction mode, power electronics, digital signal processor, Oustaloup approximation, small-signal model, settling time, voltage regulation, non-minimum phase, integral of squared error, mean squared error, TMS320F28379D, backward Euler method
News Source: Denise Maddox. (November 25, 2026). Hybrid Swarm-Bee Algorithm Enhances Fractional-Order Control Performance in Experimental Boost Converters. Scienmag.