• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Wednesday, November 25, 2026
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Health

Jordan Establishes Diagnostic Reference Levels for Three-Dimensional Breast Tomosynthesis Systems

by
November 24, 2026
in Health
Reading Time: 7 mins read
0
Jordan Establishes Diagnostic Reference Levels for Three-Dimensional Breast Tomosynthesis Systems

Jordan Establishes Diagnostic Reference Levels for Three-Dimensional Breast Tomosynthesis Systems

Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

Medical researchers across Jordan have established the nation’s first baseline diagnostic reference levels for three-dimensional digital mammography, documenting that radiation doses delivered during screening and diagnostic breast tomosynthesis examinations remain well within internationally recognized radiological safety benchmarks. The multicenter retrospective investigation, conducted across major clinical facilities in Jordan’s central province including the capital city of Amman, evaluated comprehensive imaging and dosimetric records from female patients who underwent digital breast tomosynthesis between February 3, 2025, and October 19, 2025. By analyzing technical exposure parameters, breast thickness measurements, and calculated tissue absorption values, the study establishes an empirical foundation for monitoring clinical equipment performance, curbing unwarranted patient radiation exposure, and standardizing radiation protection protocols across Jordanian healthcare institutions.

Mammography examinations represent an essential clinical tool for both screening asymptomatic women to detect breast malignancies at early developmental stages and diagnosing symptomatic patients presenting with palpable clinical abnormalities. An organized screening framework generally recommends bilateral mammography examinations every two years for women between fifty and seventy-four years of age. Data maintained by the Jordan Cancer Registry indicate that breast cancer constitutes the most prevalent malignant neoplasm among women in Jordan, accounting for 37.5 percent of all female cancer diagnoses, with a median age at diagnosis of fifty-one years across a distribution ranging from twenty to ninety-one years, compared to a median age of fifty-four years among affected males. To confront these epidemiological patterns, the Ministry of Health established the Jordan Breast Cancer Program in 2006 as a nationwide screening and early detection initiative. Prior to the program’s inception, breast cancer management focused predominantly on post-diagnostic clinical treatment because more than seventy percent of patients presented with advanced systemic disease, prompting the organization to recommend biennial screening mammography commencing for all women aged forty years and older.

The expansion of nationwide screening services encountered operational hurdles, including a recognized shortage of specialized interpreting radiologists and female-trained radiographic technologists, requiring the Jordan Breast Cancer Program to implement extensive capacity-building workshops for radiologists, radiographers, nurses, and clinical oncologists. Because mammography examinations routinely deliver ionising radiation to radiosensitive mammary glandular tissues, elevating theoretical lifetime risks of radiation-induced carcinogenesis, clinical optimization remains essential. Standard bilateral screening examinations encompass two primary anatomical views per breast: the craniocaudal projection and the mediolateral oblique projection. To assess carcinogenic radiation risk accurately, medical physicists evaluate the average glandular dose, defined as the effective absorbed radiation dose delivered specifically into the glandular tissues of an evenly compressed breast while excluding the superficial skin layers. Mechanical breast compression is systematically applied during imaging to diminish tissue thickness, reduce scattered radiation, improve image clarity, and reduce the overall absorbed dose administered to the patient in accordance with the principle that exposures should remain as low as reasonably achievable without degrading diagnostic image quality.

Diagnostic reference levels function as internationally recognized operational benchmarks established by health regulatory bodies and professional radiation protection commissions to detect abnormally high radiation doses delivered during routine examinations and to drive ongoing optimization. While established guidelines recommend deriving diagnostic reference levels from the seventy-fifth or ninety-fifth percentiles of measured patient dose distributions, prior radiological dose surveys in Jordan focused almost exclusively on computed tomography and intensity-modulated radiation therapy machines, with mammographic studies remaining exceptionally rare. Although a previous single-institution Jordanian investigation recorded local reference levels of 2.03 milligrays and 2.93 milligrays at an established cancer detection facility, national reference benchmarks across modern three-dimensional digital breast tomosynthesis systems had never been systematically quantified. As digital mammography and digital breast tomosynthesis technologies expand across Jordanian diagnostic centers, clinical equipment yields superior structural visualization of overlapping fibroglandular parenchyma but poses risks of elevated cumulative doses if technical parameters and automated exposure settings are not optimized rigorously.

To establish comprehensive local dose benchmarks, investigators reviewed clinical records from four major mammography facilities equipped with modern three-dimensional imaging platforms, collecting data from a cohort of 400 randomly selected female patients aged 18 to 85 years with compressed breast thicknesses ranging between 20 and 100 millimeters. The study cohort was divided into four equal groups distributed evenly among the participating medical centers, incorporating women regardless of baseline radiographic breast density or assigned Breast Imaging-Reporting and Data System classifications. Participating institutions operated a diverse array of advanced digital breast tomosynthesis platforms, including General Electric Healthcare Senographe Pristina systems, a vendor-neutral Philips tomosynthesis imaging unit, a Fujifilm Holdings Corporation Amulet Innovality system, a Siemens Healthineers Mammomat Inspiration PRIME 3D unit, and a modern Planmed Clarity 3D digital mammography system from Shimadzu Medical Systems, reflecting the diverse diagnostic technologies deployed across the central province.

The total analyzed dataset encompassed 1,600 individual mammographic projections comprising the four standard diagnostic views: left craniocaudal, right craniocaudal, left mediolateral oblique, and right mediolateral oblique. For every captured projection, investigators documented seven distinct patient and operational parameters from medical record archives, including the calculated average glandular dose measured in milligrays, compressed breast thickness in millimeters, tube current-exposure time product in milliampere-seconds, entrance skin exposure in milligrays, tube potential in peak kilovoltage, applied mechanical compression force in newtons, and chronological patient age. Imaging units adjusted radiation output automatically using integrated automatic exposure control mechanisms to optimize diagnostic contrast and signal-to-noise ratios. All acquired tomosynthesis series were evaluated by three qualified breast imaging radiologists with ten years of clinical specialization who reviewed image quality alongside confirmed pathological diagnoses, which included confirmed invasive lobular carcinoma and invasive ductal carcinoma cases validated by diagnostic core needle biopsies.

Because one participating tomosynthesis installation lacked automated calculation software to report entrance surface exposure directly, the research team calculated entrance skin exposure using an established radiological transformation equation that factors tube output, current-exposure product, and backscatter factors. In this mathematical formulation, entrance skin exposure equals the product of tube output factor X, exposure time product in milliampere-seconds, and the backscatter factor, where X represents the machine radiation output calibrated in milligrays per 100 milliampere-seconds at a fifty-centimeter focus distance under paddle compression. Backscatter factors for typical mammographic beam energies, exhibiting half-value layers between 0.25 and 0.40 millimeters of aluminum, contribute low correction coefficients ranging from 1.03 to 1.07. Statistical evaluations performed in spreadsheet software utilized paired one-sample Student’s t-tests to evaluate mean dose discrepancies between craniocaudal and mediolateral oblique views, while median diagnostic reference levels were calculated as the mathematical midpoint between the 75th and 95th percentiles of measured dose distributions.

The patient population presented a mean age of 44 years with a standard deviation of 10.39 years across six distinct age brackets. Patients aged 18 to 25 represented 8 percent of the cohort, while 15 percent fell between 26 and 35 years, 25 percent between 36 and 45 years, 20 percent between 46 and 55 years, 18 percent between 56 and 65 years, and 14 percent between 66 and 85 years. Technical analysis revealed that mechanical compression force increased progressively with compressed breast thickness. Across craniocaudal projections, mean compression forces rose from 119 newtons to 135 newtons and 159 newtons across thickness brackets of 37 millimeters, 43 millimeters, and 54 millimeters, alongside average tube potentials of 27.2, 28.4, and 29.6 peak kilovoltage and current-time products of 117.8, 155.9, and 175.7 milliampere-seconds. Corresponding mediolateral oblique projections demonstrated slightly elevated mean compression forces of 123 newtons, 138 newtons, and 165 newtons across identical thickness increments, while maintaining matched tube potential and exposure values across projections.

Analysis of dosimetric distributions revealed that mediolateral oblique projections yielded significantly higher entrance skin exposures and average glandular doses than corresponding craniocaudal projections, reaching statistical significance on paired t-testing with p-values below 0.05. For compressed breast thicknesses of 20 to 29 millimeters and 30 to 39 millimeters, the 75th percentile reference levels for average glandular dose were 0.89 and 0.96 milligrays on craniocaudal views compared to 0.91 and 1.13 milligrays on mediolateral oblique views. Corresponding 75th percentile entrance skin exposures measured 1.7 and 1.9 milligrays for craniocaudal versus 1.8 and 2.2 milligrays for mediolateral oblique projections. At the 95th percentile, craniocaudal and mediolateral oblique glandular doses reached 0.97 and 1.29 milligrays versus 1.16 and 1.47 milligrays across the same thickness ranges, while entrance skin exposures reached 1.9 and 2.4 milligrays versus 2.3 and 2.5 milligrays, confirming that entrance skin dose fluctuated more widely than glandular dose.

Across the entire patient collective, individual average glandular doses spanned from 0.89 to 3.11 milligrays, reflecting a threefold variation, while entrance skin exposures ranged between 1.7 and 10.5 milligrays, representing a sixfold disparity. Entrance skin exposure averaged approximately four times the calculated glandular dose across standard views, with only 3 percent of patients exceeding an entrance exposure of 10 milligrays, an incidence considerably lower than the 10 percent proportion reported in historical mammography studies. When examining thickness dependencies, maximum glandular dose and entrance exposure measured 1.23 and 4.3 milligrays at 45 millimeters compressed thickness, with entrance exposure exceeding glandular dose by a factor of 3.5. At 70 millimeters thickness, peak glandular dose reached 1.79 milligrays while entrance exposure climbed to 9.1 milligrays, exceeding glandular dose by 5.0 times. Evaluated compression forces spanned 87 to 198 newtons, never exceeding 193 newtons on average distributions, with the single largest sample of 305 projections recorded at 160 newtons for 54 millimeters compressed thickness.

Patient age did not emerge as a statistically meaningful independent predictor of glandular dose. Compressed breast thickness functioned as a strong negative predictor within the model formulation (B = 0.0385, p < 0.001), while tube voltage and entrance skin dose operated as significant positive predictors. Concurrently, tube current-exposure product and applied mechanical compression force exhibited statistically significant inverse correlations with average glandular dose (B = 0.0024, p < 0.001, and B = 0.0156, p < 0.002, respectively), highlighting how paddle pressure, tissue displacement, and automatic beam adjustments govern absorbed radiation delivery.

Comparing Jordan’s dosimetric figures with international registries demonstrated that local three-dimensional digital tomosynthesis protocols maintain competitive radiation safety profiles. The overall median diagnostic reference level across all projections in Jordan stood at 1.77 milligrays, which proved notably lower than median benchmarks reported in Dubai (3.75 milligrays) and Ghana (1.8 milligrays). At the 75th percentile, Jordan’s glandular dose level of 1.61 milligrays remained below figures from Dubai (4.60 milligrays) and Malaysia (2.05 milligrays), though higher than levels documented in Palestine and Greece. At the 95th percentile, Jordan’s glandular dose of 1.92 milligrays was markedly below figures published in Ghana (4.1 milligrays) and Malaysia (3.45 milligrays). Mean breast thickness in Jordan measured 53 millimeters, aligning closely with Malaysian (55 millimeters) and Greek (56 millimeters) data, while exceeding averages recorded in Dubai (45 millimeters) and Ghana (40 millimeters), and falling below Palestinian measurements (61 millimeters).

The study authors acknowledged specific methodological constraints, including the restricted availability of modern three-dimensional tomosynthesis systems across Jordan, which necessitated pooling clinical data across disparate equipment models and vendor platforms rather than analyzing a uniform hardware environment. Furthermore, because select clinical systems lacked integrated software capabilities to compute and display entrance skin exposure directly, researchers had to apply standardized empirical equations to derive surface exposure values mathematically from recorded operational factors. Nevertheless, the broad cohort of 1,600 analyzed images across major diagnostic facilities provides a statistically robust baseline for national practice, confirming that digital tomosynthesis can deliver high-resolution diagnostic imaging while adhering strictly to international radiation protection frameworks and fostering future clinical investigations linking radiation optimization with biopsy-proven cancer detection rates.

Subject of Research: Diagnostic reference levels and radiation dosimetry for 3D digital breast tomosynthesis in Jordan

Article Title: Diagnostic reference levels (DRLs) for 3-dimensional digital mammography in Jordan

Article References: Abufadda, M., Alzyoud, K., Saleh, H., Al najar, M., & sleim, A. A. (2026). Diagnostic reference levels (DRLs) for 3-dimensional digital mammography in Jordan. Egyptian Journal of Radiology and Nuclear Medicine, 57(1), Article 252. https://doi.org/10.1186/s43055-026-01918-6

Image Credits: AI Generated

DOI: 10.1186/s43055-026-01918-6

Keywords: 3D mammography, digital breast tomosynthesis, diagnostic reference levels, radiation dosimetry, average glandular dose, entrance skin exposure, Jordan Breast Cancer Program, radiological protection, compressed breast thickness, radiation optimization, mammography screening, craniocaudal view, mediolateral oblique view, dosimetric evaluation, medical physics, radiation safety, breast cancer screening

News Source: Ophelia Keating. (November 24, 2026). Jordan Establishes Diagnostic Reference Levels for Three-Dimensional Breast Tomosynthesis Systems. Scienmag.

Tags: 3D mammographyaverage glandular doseBreast Cancer Screeningcompressed breast thicknesscraniocaudal viewdiagnostic reference levelsdigital breast tomosynthesisdosimetric evaluationentrance skin exposureJordan Breast Cancer Programmammography screeningmedical physicsmediolateral oblique viewradiation dosimetryradiation optimizationRadiation safetyradiological protection
Share12Tweet7Share2ShareShareShare1

Related Posts

Ultrasound-Derived Fat Fraction Accurately Detects Hepatic Steatosis in Liver Tumor Patients

Ultrasound-Derived Fat Fraction Accurately Detects Hepatic Steatosis in Liver Tumor Patients

November 25, 2026
Brain PET Reconstruction Algorithms Alter Quantitative Glucose Metabolism Measurements Across Regions

Brain PET Reconstruction Algorithms Alter Quantitative Glucose Metabolism Measurements Across Regions

November 25, 2026

Collaborative Care Billing Codes Leave Forty-Four Percent of Treatment Time Unbillable

November 25, 2026

Pain and Anesthesia Journal Editors Launch Joint Integrity Initiative Across Fifteen Publications

November 25, 2026

POPULAR NEWS

  • Italian Eco-Farming Study Reveals Environmental Care Relies on Grounded Practical Compromise

    Italian Eco-Farming Study Reveals Environmental Care Relies on Grounded Practical Compromise

    29 shares
    Share 12 Tweet 7
  • Fungal Endophytes Precondition Tree Epigenomes to Enhance Thermotolerance Under Climate Warming

    29 shares
    Share 12 Tweet 7
  • Study Traces How Agrifood Labor Regimes Displace Illness Costs onto Migrant Farmworkers

    29 shares
    Share 12 Tweet 7
  • Post-Exposure Rabies Prophylaxis Clears Viral RNA and Maintains Protective Antibodies

    29 shares
    Share 12 Tweet 7

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

Comprehensive Sensory Monitoring Framework Standardizes Bridge Structural Assessment and Maintenance

AI Medical Devices Advance Diagnostic Accuracy and Personalized Patient Care in Review

Aglycosylated Antibody Targeting FAM19A5 Shows Twenty-Two-Day Human Half-Life

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 89 other subscribers
  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.