In a retrospective cross-sectional evaluation of 140,449 anatomic pathology examinations processed over a one-year period at an accredited laboratory, researchers identified 9,556 nonconformities, representing an overall pre-analytical nonconformity rate of 6.8 percent. Events categorized as patient safety risks constituted the single largest proportion of these process deviations, accounting for 43 percent of all recorded nonconformities in the primary dataset and 44.4 percent in summary classifications.
As described by investigators including Francis Rossetti Pedack and colleagues in Surgical and Experimental Pathology, the pre-analytical stage represents the most vulnerable phase of anatomic pathology workflows. Because this stage involves multiple manual steps and diverse healthcare personnel before tissue processing begins, errors introduced here are difficult to detect later and carry the potential to compromise diagnostic accuracy and patient outcomes.
The investigation drew its analytical framework from the World Health Organization’s Conceptual Framework for the International Classification for Patient Safety. Within this model, patient safety risks are defined as conditions directly impacting clinical care and diagnostic reliability, while other recorded operational issues encompass professional risks, which accounted for 34 percent of all events, administrative risks at 15 percent, and a combined 8 percent spanning clinical, environmental, occupational, and institutional risks.
The study evaluated nonconformity records stored in the computerized database of a medium-sized anatomic pathology facility that serves both Brazil’s public Unified Health System (SUS) and private healthcare providers. The facility maintains dual accreditation through the College of American Pathologists (CAP) and the Brazilian National Accreditation Organization (ONA), operating standardized quality management systems that capture pre-analytical deviations as opportunities for improvement across both healthcare sectors without sectoral stratification.
During the one-year monitoring window, the research team analyzed all logged nonconformities classified as patient safety risks, while excluding records that contained insufficient documentation for full categorization. This exclusion criterion applied to 7 percent of the patient safety records, leaving the remaining verified entries to be sorted into three distinct functional categories: request form data defects, specimen-related problems, and other process-related deviations affecting traceability and workflow continuity.
Among the examined patient safety deviations, defects in requisition forms constituted the predominant category, representing 57.1 percent of events. Traceability and workflow disruptions formed the second most frequent category at 24.3 percent, reflecting ongoing challenges in maintaining chain-of-custody and process continuity. Specimen-related problems accounted for the remaining 18.6 percent of patient safety incidents, encompassing issues such as inadequate tissue fixation, insufficient specimen volume, and discrepancies between container labels and requisition sheets.
An analysis of the request form defects revealed that missing or incorrect anatomical lesion site information was the primary documentation failure, accounting for 72.3 percent (1,699 events) of requisition errors in detailed counts and 67.2 percent across category-level summaries. Other requisition flaws included health insurance or billing code discrepancies at 12.0 percent (283 cases), incorrect or incomplete dates of birth at 10.3 percent (241 cases), patient name errors at 5.1 percent (121 cases), and maternal name omissions at 0.3 percent (6 cases).
The authors emphasized that the omission of clinical history and anatomical site details creates substantial vulnerabilities during histopathological examination. Pathologists rely directly on topographic information to achieve proper clinicopathological correlation, interpret complex tissue patterns—such as distinguishing melanocytic lesions in dermatopathology—and establish standardized reports, meaning missing data necessitates additional verification, causes diagnostic turnaround delays, and elevates error risk.
The investigators noted that pre-analytical specimen handling has grown increasingly critical alongside the adoption of immunohistochemistry and molecular pathology. Suboptimal tissue fixation damages cellular morphology, degrades antigen preservation, and compromises nucleic acid integrity, which directly impairs biomarker detection and precision oncology assays, while insufficient sample volume restricts the availability of tissue blocks for essential prognostic and predictive ancillary studies.
The researchers highlighted several inherent study limitations, noting that the data reflect the retrospective experience of a single center and may be subject to institutional underreporting. To mitigate pre-analytical vulnerabilities, the authors recommended standardized requisition templates, continuous education programs for clinical teams collecting specimens, systematic root-cause analyses, and internal reporting mechanisms to detect procedural discrepancies before laboratory tissue processing begins.
The conceptual organization of anatomic pathology workflows relies on a foundational tripartite model comprising the pre-analytical, analytical, and post-analytical phases of examination. Research into laboratory safety has long established that pre-analytical operations harbor the overwhelming majority of diagnostic discrepancies. This heightened vulnerability stems primarily from the heavy reliance on manual handling and the complex involvement of multidisciplinary healthcare teams outside the direct oversight of pathology personnel. Consequently, failures originating at this preliminary juncture propagate through every downstream analytical stage, directly jeopardizing interpretive accuracy, delaying clinical turnaround times, and magnifying the hazard of diagnostic misclassification.
To quantify operational failures rigorously, the investigators evaluated computerized database records compiled under institutional quality management protocols. Across the entire twelve-month study interval, the laboratory processed an overall volume of 140,449 examinations, capturing 9,556 distinct process nonconformities that were systematically logged as opportunities for institutional improvement. In the methodology established by the research team, the nonconformity rate was determined through the explicit mathematical calculation dividing the total count of logged nonconformities by the aggregate examination volume, subsequently multiplied by one hundred to produce the benchmark proportion of 6.8 percent. The facility under evaluation maintains programmatic accreditation through both the College of American Pathologists and the Brazilian National Accreditation Organization, reinforcing adherence to internationally recognized laboratory performance standards. Furthermore, the institutional database systematically gathered procedural records encompassing both public patients served by Brazil’s Unified Health System and individuals treated within private healthcare networks. Rather than separating entries by financing stream, the evaluation examined all submitted accessions indiscriminately, thereby providing a comprehensive, cross-sectional perspective on pre-analytical reliability across diverse clinical ordering environments.
The analytical taxonomy deployed by the authors was structured around the World Health Organization’s Conceptual Framework for the International Classification for Patient Safety. Within this standardized model, healthcare hazards are classified by their primary functional impact on service delivery and clinical well-being. Patient safety risks encompass events or conditions that directly threaten the diagnostic accuracy of tissue reports or compromise clinical management pathways. In contrast, other risk categories cataloged within the institutional management system represent broader operational, administrative, or environmental vulnerabilities. Specifically, professional risks represented 34 percent of all documented nonconformities, reflecting events that challenge practitioner workflows or staff responsibilities. Administrative risks constituted 15 percent of total logged events, encompassing organizational and procedural breakdowns in clerical operations. An additional 8 percent of deviations were grouped across clinical, environmental, occupational, and institutional domains.
Beyond administrative and professional deviations, the 18.6 percent of patient safety nonconformities stemming from specimen-related issues carry severe clinical ramifications for modern laboratory medicine. The authors observed that these physical defects typically involve inadequate chemical fixation, insufficient tissue biopsy volume, or discrepancies between physical container markings and paperwork. In contemporary diagnostic pathology, tissue preservation directly dictates the viability of advanced diagnostic testing. Inadequate fixation alters cellular architecture and degrades protein antigens, directly compromising immunohistochemical staining and diagnostic interpretation. Furthermore, compromised pre-analytical handling threatens nucleic acid integrity, introducing artifacts that impair molecular assays and precision biomarker evaluations. Similarly, when obtaining insufficient biopsy volume, laboratory staff may lack adequate diagnostic material to perform essential ancillary predictive and prognostic testing. Because precision oncology relies heavily on reproducible immunohistochemistry and molecular profiling to guide targeted therapies, pre-analytical specimen handling protocols for tissue immersion, chemical fixation, and transport have become vital prerequisites for diagnostic accuracy and personalized patient care.
Process-control vulnerabilities were further highlighted by the 24.3 percent of patient safety events tied to workflow interruptions and specimen traceability failures. The authors noted that robust procedural verification acts as a critical line of defense against diagnostic mistakes. Because anatomic pathology lacks a universal gold standard for error detection, laboratory workflows must incorporate rigid verification procedures to identify custody deviations early.
To address recurring documentation breakdowns, the researchers emphasized targeted educational interventions alongside strict reporting protocols. External training programs directed at clinical staff who collect and submit biopsies can heighten clinical awareness regarding the indispensable value of complete requisition forms. Concurrently, internal training within laboratories reinforces early failure detection before physical tissue alteration commences. Although the retrospective, single-center design and potential underreporting represent clear methodological constraints, systematic nonconformity tracking serves as a powerful continuous improvement mechanism to safeguard diagnostic reliability across anatomic pathology services.
Subject of Research: Pre-analytical nonconformities and patient safety risks in anatomic pathology laboratories
Article Title: Pre-analytical nonconformities in anatomic pathology: frequency and patient safety implications
Article References: Pedack, F. R., Cardoso, D. C. L., Junior, A. A. C., de Oliveira, D., Pickler, J. G. J., Barbosa, C., Junior, H. F., Franczak, P. F., Silva, B. L., de França, P. H. C., & Coelho, K. M. D. P. A. (2026). Pre-analytical nonconformities in anatomic pathology: frequency and patient safety implications. Surgical and Experimental Pathology, 9(1), Article 43. https://doi.org/10.1186/s42047-026-00255-2
Image Credits: AI Generated
DOI: 10.1186/s42047-026-00255-2
Keywords: anatomic pathology, pre-analytical errors, patient safety, nonconformities, laboratory quality management, request form defects, lesion site documentation, specimen traceability, retrospective cross-sectional study, College of American Pathologists, Organização Nacional de Acreditação, Brazilian Unified Health System, specimen fixation, diagnostic accuracy, International Classification for Patient Safety, workflow failures, clinicopathological correlation
News Source: Ophelia Keating. (November 24, 2026). Pathology Laboratory Study Identifies Missing Lesion Sites as Leading Pre-Analytical Error. Scienmag.