Ophthalmic surgeons in Romania have documented the successful management of a visually impaired eye presenting with an intricate convergence of anterior and posterior segment risk factors, demonstrating that a tailored, stepwise operative strategy can restore sight while preventing tissue decompensation. Writing in Frontiers in Medicine, the surgical team detailed the clinical reasoning and multi-stage intervention carried out for a thirty-five-year-old male patient who developed a severe, sight-threatening cataract following earlier procedures for high myopia and complicated retinal detachment. The patient presented with a dramatic reduction in best-corrected visual acuity to 1.3 logMAR in his left eye, an impairment stemming primarily from advanced lens opacities that formed against a background of compromised ocular architecture and diminished physiological reserves.
The patient’s complex ocular history began nearly a decade earlier when he underwent surgical implantation of an iris-fixated phakic intraocular lens to treat severe refractive error. Specifically, an Artiflex model with a spherical power of minus 12.50 diopters had been fixated to his iris tissue to address severe axial myopia. Seven years after that initial refractive intervention, the patient developed a macula-off rhegmatogenous retinal detachment in the same eye, necessitating a twenty-five-gauge pars plana vitrectomy. Vitreoretinal repair involved confirming posterior vitreous detachment, core and peripheral vitrectomy, vitreoretinal traction release, subretinal fluid drainage through an existing retinal break, application of perfluorocarbon liquid, endolaser photocoagulation, fluid-air exchange, and internal tamponade using 1,300-centistoke conventional silicone oil. While the vitreoretinal procedure successfully reattached the retina, the patient subsequently reported progressive, painless loss of vision starting two months postoperatively.
Upon referral and diagnostic evaluation, slit-lamp biomicroscopy revealed a multifactorial anterior segment scenario that significantly magnified operative complexity. The anterior chamber harbored free-floating silicone oil droplets that had migrated past the iris plane, accompanied by extensive posterior synechiae that tethered the iris to the underlying cataractous crystalline lens. A dense, fibrotic pupillary membrane occupied the pupillary margin, compounding the pupillary constriction and restricting visualization. A pre-existing large peripheral iridectomy was also noted, altering local iris dynamics. Importantly, specular microscopy demonstrated a reduced corneal endothelial cell density of 1,500 cells per square millimeter, indicating severely limited endothelial reserve and making the cornea highly susceptible to irreversible decompensation from mechanical manipulation or elevated fluidic turbulence.
Preoperative diagnostic testing and biometric calculations further illustrated the anatomical extremes of the affected eye. Optical biometry documented an axial length of 29.52 millimeters, reflecting profound axial elongation typical of high myopia. Keratometry demonstrated a flat meridian of 42.96 diopters at 72 degrees and a steep meridian of 43.76 diopters at 162 degrees, yielding an average corneal curvature of 43.36 diopters with 0.80 diopters of corneal astigmatism. Central corneal thickness was measured at 594 micrometers, anterior chamber depth was 3.14 millimeters, and the crystalline lens thickness was 5.12 millimeters. Employing the Barrett formula targeted for emmetropia, surgeons selected a plus 6.00 diopter AcrySof IQ SN60WF posterior chamber intraocular lens, which provided a predicted postoperative spherical equivalent of minus 0.42 diopters and estimated residual astigmatism of 0.82 diopters, with baseline intraocular pressure recorded at 13 mmHg.
Faced with competing surgical priorities, the operating team rejected standard phacoemulsification paradigms in favor of a deliberate, step-by-step risk-mitigation approach under local retrobulbar anesthesia. The procedure commenced with the creation of two side-port incisions and the immediate deployment of an ophthalmic viscosurgical device to establish anterior chamber stability and cushion the fragile corneal endothelium. Because of the patient’s diminished endothelial reserve, surgeons implemented a dispersive-cohesive soft-shell technique. Viscoat, a dispersive combination of 3 percent sodium hyaluronate and 4 percent sodium chondroitin sulfate, was injected across the endothelium, followed by central injection of Eyefill S.C., a cohesive 2 percent sodium hyaluronate formulation, which pushed the protective dispersive layer against the posterior corneal surface while creating adequate intraocular working room and displacing silicone oil droplets away from the operative field.
Rather than leaving the phakic implant in place to stabilize the anterior chamber during cataract removal—a technique sometimes described for less complicated presentations—the surgeons prioritized early explantation to gain essential maneuvering space and direct surgical access. Using the pre-existing peripheral iridectomy, posterior synechiae were meticulously separated with a spatula under viscoelastic protection. The iris-claw Artiflex lens was disenclavated from the iris tissue using controlled mechanical maneuvers designed to limit traction on the iris base and prevent contact with the corneal endothelium. The main corneal incision was enlarged to 3.5 millimeters to facilitate extraction of the phakic lens, after which the anterior chamber was immediately reinflated with additional viscosurgical device to prevent chamber collapse and suppress further anterior migration of silicone oil.
Once the phakic lens was removed, the operating team addressed the mechanical obstacles restricting access to the cataractous crystalline lens. The fibrotic pupillary membrane at the pupil margin was mechanically peeled, followed by controlled mechanical stretching of the rigid pupillary aperture to achieve adequate visualization of the anterior lens capsule. A continuous curvilinear capsulorhexis was then successfully fashioned. Recognizing that the crystalline lens was relatively soft, the surgeons deliberately avoided applying ultrasound phacoemulsification energy, thereby removing the threat of ultrasonic endothelial cell trauma. Instead, cataract removal was achieved entirely through bimanual irrigation and aspiration, utilizing low vacuum levels and tangential aspiration vectors to minimize physical stress on the capsular bag and avoid straining potentially fragile zonular fibers.
Following complete cortical cleanup without any signs of zonular instability, the capsular bag was refilled with ophthalmic viscosurgical device, and the plus 6.00 diopter foldable acrylic intraocular lens was placed precisely inside the bag. All residual viscoelastic material was thoroughly aspirated from both the anterior chamber and the retro-lenticular space. To prevent postoperative infection, one milligram of cefuroxime in 0.1 milliliters of solution was administered intracamerally via a side port. The side ports were sealed with stromal hydration, while the enlarged 3.5-millimeter clear-corneal incision was secured using a single interrupted 10-0 monofilament nylon suture with the knot buried. At the conclusion of this initial surgical intervention, the anterior chamber was well formed with no evidence of ongoing silicone oil migration.
Surgeons deliberately elected to stage the surgical management by deferring silicone oil extraction until a later date, prioritizing tissue recovery over simultaneous procedures. Due to the marked intraoperative manipulation required for synechiolysis, pupillary membrane peeling, and phakic lens explantation, combined with limited immediate fundus visibility through transient corneal and pupillary changes, performing concurrent vitreoretinal surgery was judged an unnecessary hazard. Postoperative medical management included intensive topical netilmicin and dexamethasone combination drops, supplemental dexamethasone, bromfenac ophthalmic solution, and tropicamide, alongside preservative-free artificial tears. The main corneal suture was removed at three weeks, by which time early postoperative corneal edema had cleared without requiring pressure-lowering interventions.
Three months after the primary cataract extraction, once anterior segment inflammation had completely subsided and corneal clarity was fully restored, the patient underwent a planned second procedure consisting of pars plana silicone oil extraction and fluid-air exchange. Subsequent fundus examination confirmed that the retina remained entirely attached without recurrent detachment or newly formed retinal breaks. Over an extended follow-up period of twelve months, the patient demonstrated an excellent functional and structural recovery. Best-corrected visual acuity reached and remained stable at 0.22 logMAR, intraocular pressure stayed within normal limits without medication, the posterior chamber lens remained perfectly centered, and the retina remained attached. Endothelial cell density measured 1,183 cells per square millimeter at the one-year mark, confirming that corneal decompensation was successfully avoided despite the demanding operative interventions.
In evaluating the broader relevance of the intervention, the clinical authors highlighted the literature surrounding iris-claw phakic intraocular lens explantation, which identifies progressive endothelial cell loss and cataractogenesis as frequent late sequelae. While earlier publications have reported alternative strategies such as retaining the phakic implant during cataract emulsification, the presence of severe posterior synechiae, pupillary fibrosis, and silicone oil droplets demanded prompt phakic lens removal in this instance to ensure visualization and surgical maneuverability. Although single-patient reports cannot establish definitive clinical protocols or determine comparative efficacy across diverse populations, the case illustrates how deliberate, low-energy surgical sequencing and proactive endothelial protection can achieve favorable anatomical and visual outcomes in high-risk eyes presenting with overlapping anterior and posterior segment pathologies.
Subject of Research: Surgical management of cataract and iris-fixated phakic intraocular lens following retinal detachment repair
Article Title: Complex cataract extraction in a highly myopic eye with an iris-fixated phakic intraocular lens after retinal detachment repair: a case report
Article References: Rosca, C., Pac, C. P., & Munteanu, M. (2026). Complex cataract extraction in a highly myopic eye with an iris-fixated phakic intraocular lens after retinal detachment repair: a case report. Frontiers in Medicine, 13, Article 1942506. https://doi.org/10.3389/fmed.2026.1942506
Image Credits: AI Generated
DOI: 10.3389/fmed.2026.1942506
Keywords: cataract extraction, phakic intraocular lens, iris-fixated lens, Artiflex lens, retinal detachment, high myopia, silicone oil tamponade, endothelial cell density, posterior synechiae, pupillary membrane, capsulorhexis, viscosurgical device, soft-shell technique, bimanual irrigation-aspiration, vitrectomy, ophthalmic surgery
News Source: Ophelia Keating. (November 24, 2026). Staged Surgery Successfully Restores Vision in Complex Post-Retinal Detachment Eye. Scienmag.