A revised version of the EuroQol Health and Wellbeing 9 instrument, designated version 1.2, showed psychometric performance that was at least equivalent or slightly superior to version 1.1 in testing across the Netherlands and the United States. The evaluation assessed whether revisions introduced to item wording, response option labels, and item ordering influenced measurement performance across adult populations in both nations. Researchers observed that the updated measure maintained robust properties across evaluated criteria while showing consistent performance between both surveyed countries.
The EuroQol Health and Wellbeing 9, known as the EQ-HWB-9, along with the longer EQ-HWB form, is designed to capture dimensions relevant to healthcare users, social care users, and their caregivers. Following preliminary testing of the experimental version 1.1 in 2022, investigators identified specific areas where refinements could be made to item phrasing, response category labels, and the overall sequence of items. In response to those preliminary findings, a modified experimental version 1.2 was formally established in 2024 to address those potential measurement refinements.
The investigation evaluated data gathered from 3,783 adult participants recruited through an online panel using quota sampling methods. The total sample comprised 1,571 individuals from the Netherlands and 2,212 individuals from the United States. Every participant completed the modified EQ-HWB-9 version 1.2 within a broader survey framework. In addition, a subset of the cohort was randomly assigned to one of four study arms, which incorporated the EQ-HWB long form, the earlier EQ-HWB-9 version 1.1, and several variants of the instrument.
Psychometric analysis involved evaluating response distributions, setting instrument-level ceiling and floor thresholds at 15 percent. To evaluate known group validity, researchers conducted Mann-Whitney U tests across five pre-specified participant subgroups: EQ visual analogue scale scores, the presence of chronic health conditions, somatic symptom severity, satisfaction with health, and satisfaction with life. In addition, convergent validity assessments used Spearman rank correlations comparing the EQ-HWB-9 versions against each other, the EQ-HWB long form, and EQ-5D-5L level sum scores.
The investigators found that instrument-level floor and ceiling effects were absent across the evaluated versions, with the sole exception of a marginal ceiling effect of 15.3 percent observed in the Dutch sample for version 1.1. In contrast, the earlier version 1.1 consistently displayed a higher proportion of Level 1 responses compared to version 1.2. In the United States, version 1.1 produced 60.5 percent Level 1 responses for day-to-day activities compared to 51.9 percent for version 1.2, alongside 63.0 percent for control compared to 53.4 percent for version 1.2. In the Netherlands, version 1.1 yielded 60.1 percent Level 1 responses for day-to-day activities versus 51.8 percent for version 1.2, and 59.5 percent for control versus 56.0 percent for version 1.2.
Across known groups, all tested versions demonstrated statistically significant discrimination within both the Netherlands and the United States, registering large effect sizes across four of the five defined subgroups. When assessing cross-version agreement, version 1.2 exhibited very strong Spearman correlation coefficients with version 1.1, reaching a correlation of 0.88 in the United States and 0.85 in the Netherlands. These relationships indicated strong measurement coherence between the two experimental iterations of the nine-item instrument.
Convergent validity was further demonstrated through external reference instruments, including the EQ-5D-5L, the EQ visual analogue scale, global health satisfaction, and the Satisfaction With Life Scale. Across both countries, version 1.2 demonstrated slightly higher correlation coefficients with these external measures than version 1.1. At the individual item level, convergent validity between matched items from version 1.2 and version 1.1 ranged from strong to very strong, with Spearman correlations between 0.57 and 0.82 in both countries, with similar concordance demonstrated against conceptually matched items from the EQ-5D-5L.
Subject of Research: Psychometric evaluation of wording and response modifications in the EQ-HWB-9
Article Title: Do wording and response option modifications to the EQ-HWB-9 affect measurement performance? Evidence from the Netherlands and the USA
Article References: Akanksha, A., Palma, A. D., Rencz, F., Peasgood, T., Mulhern, B., & Finch, A. P. (2026). Do wording and response option modifications to the EQ-HWB-9 affect measurement performance? Evidence from the Netherlands and the USA. Health and Quality of Life Outcomes. https://doi.org/10.1186/s12955-026-02676-9
Image Credits: AI Generated
DOI: 10.1186/s12955-026-02676-9
Keywords: EQ-HWB-9, EQ-HWB, psychometric performance, convergent validity, known group validity, ceiling effects, floor effects, EQ-5D-5L, EQ VAS, health and wellbeing, quota sampling, Netherlands, United States, somatic symptoms, Satisfaction With Life Scale, item wording
News Source: Ophelia Keating. (November 24, 2026). Modified EQ-HWB-9 Shows Equivalent or Superior Measurement Performance Across Two Countries. Scienmag.



