A large-scale retrospective study involving over 2,000 infants born before 29 weeks of gestation has revealed that the use of central venous catheters (CVCs) during the neonatal period is not independently associated with improved long-term somatic growth or psychomotor outcomes at preschool age. Conducted by researchers within the German Neonatal Network, the analysis addresses a long-standing clinical uncertainty regarding whether the routine placement of these catheters—often employed to facilitate parenteral nutrition in the most vulnerable preterm neonates—confers enduring developmental benefits or poses hidden risks that might outweigh such perceived advantages. The primary findings indicate that while unadjusted data might suggest a correlation between catheter usage and poorer outcomes, these observed differences disappear when adjusting for the underlying severity of illness, such as lower gestational age and higher rates of prematurity-related morbidities, suggesting that the clinical context surrounding catheter placement, rather than the device itself, is the primary driver of patient status.
The study population consisted of 2,072 very low birth weight infants (VLBWI) who were enrolled in the German Neonatal Network between 2009 and 2016 and who participated in a comprehensive, standardized follow-up assessment when they were between five and seven years of age. Given the observational nature of the cohort, researchers utilized multivariate regression models to evaluate the associations between CVC use and long-term outcomes, including cognitive performance measured by the Wechsler Preschool and Primary Scale of Intelligence (WPPSI-III) and behavioral health assessed through the Strengths and Difficulties Questionnaire (SDQ). Furthermore, the team performed propensity score matching—a robust statistical method intended to reduce the influence of selection bias and unmeasured confounding by balancing key variables between the groups—to ensure that the comparisons made were between infants with comparable clinical risk profiles at the time of their initial hospitalization.
In clinical practice, central venous catheters are frequently utilized for VLBWI who require parenteral nutrition during the initial period of enteral feeding advancement. These catheters provide a reliable method for administering high-concentrated amino acids, lipids, and other essential nutrients, effectively minimizing the need for multiple venipuncture procedures. However, the use of CVCs is also inherently tied to an increased risk of complications, including bloodstream infections and potential inflammatory stress during the most critical phases of brain development. For many years, the assumption has been that the benefits of optimized, high-volume parenteral intake supported by CVCs would promote better growth and improved neurodevelopmental trajectories; yet, clear scientific evidence verifying these long-term advantages has been remarkably sparse until the present investigation.
Initial analysis of the follow-up cohort highlighted significant differences in the neonatal characteristics of infants who received a CVC compared to those managed with exclusively peripheral venous access. Approximately 74% of the infants in the study cohort had a history of CVC use. These children were notably more immature, with a significantly lower mean gestational age—25.97 weeks compared to 26.97 weeks for the non-CVC group—and exhibited lower somatic parameters at birth, including weight, body length, and head circumference. Moreover, infants in the CVC group experienced higher rates of clinical and culture-proven sepsis as well as higher incidences of intraventricular hemorrhage. These findings demonstrate that the group receiving catheters represented a more biologically and clinically vulnerable population from the outset, a factor that naturally influences comparisons of long-term developmental outcomes.
Before applying rigorous risk adjustment, the study observed that children with a history of neonatal CVC use exhibited significantly lower weight, head circumference, and body mass index z-scores at preschool age. Furthermore, these children demonstrated lower cognitive scores and higher behavioral difficulty scores on standardized assessments compared to their peers without prior CVC exposure. However, the application of multivariate linear regression models—which specifically accounted for variables such as gestational age, birth weight, small for gestational age status, sepsis, and intracranial hemorrhage—substantially altered this picture. The analysis revealed that the CVC exposure itself was not associated with differences in long-term weight, length, head circumference, or overall cognitive performance, effectively neutralizing the premise that the catheterization procedure was a direct determinant of poorer long-term status.
Crucially, the study identified a significant link between the timing of enteral feeding advancement and long-term cognition. The researchers observed that in infants who received a CVC, the achievement of full enteral feeding occurred approximately eight days later than in infants without such catheters—a duration of 21.5 days compared to 13.2 days. Subsequent statistical modeling confirmed that this delay was independently associated with reduced intelligence quotient scores at preschool age, corresponding to an estimated decrease of approximately 0.07 IQ points for every additional day required to reach full enteral feeding. This observation provides a compelling shift in the focus of nutritional care, suggesting that the speed of advancing enteral nutrition is a critical modifiable factor, whereas the reliance on parenteral nutrition via a CVC may inadvertently delay this advancement, thereby indirectly impacting cognitive outcomes.
To provide further evidence for these conclusions, the team employed a propensity score matching analysis, where 412 to 488 pairs of infants were matched based on sex, gestational age, intrauterine growth restriction, maternal education, and intraventricular hemorrhage. The matching quality was verified by confirming that standardized mean differences for all key variables remained below 0.1, indicating a high level of balance between the two cohorts. Within these perfectly balanced matched pairs, the outcomes for growth and cognition remained comparable. Although children without a history of CVC use showed slightly higher BMI z-scores, the effect size was described as small, suggesting that the clinical impact on overall growth parameters is negligible. This confirmation through matching underscores the robustness of the primary finding that CVC use does not yield long-term cognitive or growth benefits.
The discussion of these findings emphasizes the growing recognition of the “less is more” principle in modern neonatal intensive care. The results challenge the assumption that routine CVC placement is universally protective, instead suggesting that physicians should carefully evaluate the indications for such devices through a lens of stewardship. While central venous access remains an essential tool for critically ill or extremely immature neonates, the potential for complications—particularly when considering the associated delay in enteral nutrition—suggests that clinicians should prioritize peripheral venous access and early enteral feeding advancement whenever it is clinically feasible and safe. By reducing the reliance on CVCs, hospitals may simultaneously lower the risk of catheter-associated infections and support the physiological development of the preterm infant.
The study does acknowledge several limitations inherent to its design. As an observational population-based cohort, the study cannot establish definitive causality, only associations. Furthermore, the dataset lacked specific information regarding the precise timing of catheter insertion and the specific composition of the feeds administered. The researchers also noted that despite extensive efforts to control for confounding via regression and matching, residual confounding—factors that remain unmeasured or poorly captured in registry data—cannot be entirely ruled out. Nonetheless, the findings align with an emerging body of research suggesting that the rapid, safe advancement of enteral feeding, where possible, represents a more effective strategy for improving long-term neurodevelopment than the prolonged reliance on intensive parenteral nutrition protocols.
In conclusion, the data provide compelling evidence against the automatic or routine use of central venous catheters in very low birth weight infants as a strategy for ensuring better long-term growth and neurobehavioral development. The study found that once patient vulnerability at birth is accounted for, the device use itself neither boosts cognitive performance nor improves long-term physical growth. Conversely, the negative correlation between delayed enteral feeding and cognitive outcomes points toward the importance of accelerating enteral nutrition as a key target for clinical intervention. These findings support a shift in neonatal practice toward a more restrictive use of invasive devices, favoring earlier enteral advancement to optimize the developmental trajectories of this highly vulnerable patient cohort.
Subject of Research: Clinical evaluation of central venous catheter usage and long-term neurodevelopmental outcomes in very low birth weight preterm infants.
Article Title: The impact of central venous catheter use on long-term growth and neurobehavioral outcome in preterm children born < 29 weeks of gestation
Article References: Silwedel, C., Retzmann, J., Fortmann, I., Grimm, A., Häfke, A., Kleindiek, F., Hanke, K., Wiechers, C., Felderhoff-Müser, U., Ehrhardt, H., Essers, J., Herting, E., Spiegler, J., Göpel, W., & Härtel, C. (2026). The impact of central venous catheter use on long-term growth and neurobehavioral outcome in preterm children born < 29 weeks of gestation. Molecular and Cellular Pediatrics, 13(1), Article 35. https://doi.org/10.1186/s40348-026-00247-y
Image Credits: AI Generated
DOI: 10.1186/s40348-026-00247-y
Keywords: Neonatology, Preterm Infants, Central Venous Catheter, VLBWI, Neurodevelopment, Pediatric Growth, Cognitive Outcome, Enteral Feeding, Clinical Practice, German Neonatal Network, Somatic Growth, Long-Term Outcomes, Nutritional Support, Intensive Care, Pediatrics Research, Cohort Study, Preschool Age, Health Policy
News Source: Harold Sullivan. (November 18, 2026). Central Venous Catheter Use Not Linked to Long-Term Preterm Developmental Outcomes. Scienmag.



