• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Saturday, November 21, 2026
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Health

AI Cervical Screening Shows High Specificity but Limited Sensitivity in Indonesian Study

by
November 14, 2026
in Health
Reading Time: 3 mins read
0
AI Cervical Screening Shows High Specificity but Limited Sensitivity in Indonesian Study

AI Cervical Screening Shows High Specificity but Limited Sensitivity in Indonesian Study

Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

Automated and hybrid artificial intelligence cervical imaging workflows demonstrated high specificity and negative predictive value but exhibited limited sensitivity when evaluated against routine visual inspection with acetic acid in community-based screening. The multicenter investigation examined the concordance of algorithmic image evaluation systems with routine visual screening across multiple healthcare facilities, finding that both technological approaches demonstrated notable limitations in identifying positive cases identified by clinical staff.

Visual inspection with acetic acid remains widely utilized for cervical precancer screening throughout low- and middle-income countries, serving as an accessible frontline method. However, the procedure is recognized to be subject to operator-dependent variability between different healthcare providers. Although automated cervical imaging systems have been introduced with the goal of improving diagnostic consistency, their performance across heterogeneous real-world clinical settings has remained insufficiently characterized.

To evaluate these technologies under field conditions, researchers conducted a multicenter cross-sectional study that enrolled 253 women undergoing cervical screening across four facilities in West Java, Indonesia. The screening evaluations took place between October 2025 and January 2026. Within the study framework, routine visual inspection with acetic acid was employed as the operational comparator rather than an established histopathological reference standard.

The study protocol assessed cervical images captured both before and after the application of acetic acid. These paired images were processed through two separate screening workflows: an automated artificial intelligence system and a hybrid workflow that incorporated expert clinical review. Screening results from both workflows were dichotomized into positive or negative classifications, and concordance relative to routine visual inspection was evaluated using Cohen’s kappa, sensitivity, specificity, positive predictive value, negative predictive value, and overall agreement.

Across the cohort of 253 women, routine visual inspection identified 23 participants, or 9.1 percent of the total sample, as positive. Compared against these routine inspection results, the automated artificial intelligence system demonstrated an overall agreement of 88.9 percent and moderate concordance, with a Cohen’s kappa of 0.421 and a 95 percent confidence interval of 0.266 to 0.622. The automated system achieved a sensitivity of 56.5 percent with a 95 percent confidence interval of 34.5 to 76.8 percent, a specificity of 92.2 percent with a 95 percent confidence interval of 87.9 to 95.3 percent, a positive predictive value of 41.9 percent, and a negative predictive value of 95.5 percent.

The hybrid workflow incorporating expert review likewise reached an overall agreement of 88.9 percent, but showed only fair concordance with a Cohen’s kappa of 0.206 and a 95 percent confidence interval of 0.014 to 0.398. Relative to visual inspection, the hybrid workflow showed a sensitivity of 21.7 percent with a 95 percent confidence interval of 7.5 to 43.7 percent, a specificity of 95.7 percent with a 95 percent confidence interval of 92.1 to 97.9 percent, a positive predictive value of 33.3 percent, and a negative predictive value of 92.4 percent. While site-specific agreement varied across the four facilities, analyses at individual locations were limited by the sparse number of positive cases.

The researchers concluded that both the automated and hybrid workflows provided high specificity and high negative predictive value but suffered from limited sensitivity when evaluated against routine visual inspection with acetic acid. The findings emphasize the performance variability of artificial intelligence screening across real-world environments and indicate the critical role of standardized image acquisition. The authors noted that histopathological validation remains necessary to establish true diagnostic accuracy and clinical utility.

Subject of Research: Concordance of AI-assisted cervical imaging systems with visual inspection with acetic acid

Article Title: Multicenter evaluation of concordance between AI-assisted and hybrid AI-assisted cervical imaging systems and visual inspection with acetic acid in community-based cervical precancer screening

Article References: Zenyda, R. R. S., Alhayat, M. R. V. A., Wardhana, R. M. W., Adzkia, Q., Nabiylah, N. A., Zahran, M. G. S., Mukhayadi, H., Suardi, D., Mantilidewi, K. I., Agustian, D., & Hidayat, Y. M. (2026). Multicenter evaluation of concordance between AI-assisted and hybrid AI-assisted cervical imaging systems and visual inspection with acetic acid in community-based cervical precancer screening. BMC Medical Imaging. https://doi.org/10.1186/s12880-026-03002-x

Image Credits: AI Generated

DOI: 10.1186/s12880-026-03002-x

Keywords: cervical precancer screening, visual inspection with acetic acid, AI-assisted cervical imaging, hybrid AI workflow, Cohen's kappa, diagnostic concordance, West Java, Indonesia, cross-sectional study, screening sensitivity, screening specificity, positive predictive value, negative predictive value, operator variability, standardized image acquisition, histopathological validation, multicenter evaluation, community-based screening

News Source: Ophelia Keating. (November 14, 2026). AI Cervical Screening Shows High Specificity but Limited Sensitivity in Indonesian Study. Scienmag.

Tags: AI-assisted cervical imagingcervical precancer screeningCohen's kappacommunity-based screeningCross-sectional Studydiagnostic concordancehistopathological validationhybrid AI workflowIndonesiamulticenter evaluationnegative predictive valueoperator variabilitypositive predictive valuescreening sensitivityscreening specificitystandardized image acquisitionvisual inspection with acetic acidWest Java
Share12Tweet7Share2ShareShareShare1

Related Posts

Chaperone Protein CNIH4 Governs Exercise Metabolism and Adrenergic Receptor Delivery in Mice

Chaperone Protein CNIH4 Governs Exercise Metabolism and Adrenergic Receptor Delivery in Mice

November 21, 2026
Hyperdominant Left Anterior Descending Artery Can Cause Multi-Territorial Myocardial Ischemia

Hyperdominant Left Anterior Descending Artery Can Cause Multi-Territorial Myocardial Ischemia

November 21, 2026

Kaempferol Reduces Cardiac Fibrosis and Improves Ejection Fraction in Mice

November 21, 2026

Dexamethasone Implant Shows No Six-Month Benefit in Epiretinal Membrane Surgery

November 21, 2026

POPULAR NEWS

  • Nationwide Survey Shows Chinese Quality of Life Rebounded After Omicron Wave

    Nationwide Survey Shows Chinese Quality of Life Rebounded After Omicron Wave

    29 shares
    Share 12 Tweet 7
  • Non-invasive embryo genetic testing does not improve ongoing pregnancy rates in trial

    29 shares
    Share 12 Tweet 7
  • Comprehensive Review Details Multicellular Mechanisms Driving Primary Sclerosing Cholangitis Progression

    29 shares
    Share 12 Tweet 7
  • Study Links Fecal Enterococcus and Tyramine in Subacute Hypertensive Brain Hemorrhage

    29 shares
    Share 12 Tweet 7

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

Multimodal Edge AI System Accurately Detects Driver Impairment in Real-Time Simulator Tests

Chaperone Protein CNIH4 Governs Exercise Metabolism and Adrenergic Receptor Delivery in Mice

Spatial Skip-Connected Attention Model Accurately Predicts Urban Traffic From Air Quality

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 88 other subscribers
  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.