• HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
Monday, November 16, 2026
BIOENGINEER.ORG
No Result
View All Result
  • Login
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
  • HOME
  • NEWS
  • EXPLORE
    • CAREER
      • Companies
      • Jobs
        • Lecturer
        • PhD Studentship
        • Postdoc
        • Research Assistant
    • EVENTS
    • iGEM
      • News
      • Team
    • PHOTOS
    • VIDEO
    • WIKI
  • BLOG
  • COMMUNITY
    • FACEBOOK
    • INSTAGRAM
    • TWITTER
No Result
View All Result
Bioengineer.org
No Result
View All Result
Home NEWS Science News Chemistry

Green Chiral Chromatography Method Accurately Analyzes Key Local Anesthetics

by
November 10, 2026
in Chemistry
Reading Time: 6 mins read
0
Green Chiral Chromatography Method Accurately Analyzes Key Local Anesthetics

Green Chiral Chromatography Method Accurately Analyzes Key Local Anesthetics

Share on FacebookShare on TwitterShare on LinkedinShare on RedditShare on Telegram

Analytical chemists have established and validated a rapid, environmentally benign high-performance liquid chromatography procedure capable of resolving the local anesthetics levobupivacaine and ropivacaine from their respective chiral impurities using a polysaccharide-based chiral stationary phase operated under hydro-organic conditions. The analytical workflow, detailed in a study published in BMC Chemistry, resolves the active S-enantiomer forms from their unwanted R-enantiomers in less than eight minutes while eliminating the toxic hydrocarbon solvents, complex ion-pairing additives, and hazardous organic modifiers historically required for such stereoselective pharmaceutical separations. By demonstrating baseline resolution on an amylose-derived stationary phase using a simple binary eluent of isopropanol and water, the investigative team delivered a sustainable analytical framework directly tailored to drug substance evaluation and commercial finished injection quality control.

Amino amide local anesthetics such as bupivacaine and ropivacaine possess a stereogenic carbon center located within their heterocyclic ring structure adjacent to the amide linkage. While racemic bupivacaine has long been administered in clinical anesthesia, the R-configured enantiomer is known to induce severe cardiotoxicity and neurotoxicity when compared to the S-enantiomer. Consequently, pure levobupivacaine—chemically designated as S(-)-bupivacaine—and S(-)-ropivacaine have become the preferred clinical alternatives because of their notably safer therapeutic profiles. Regulatory authorities, including the United States Food and Drug Administration and the European Medicines Agency, actively promote single-enantiomer drug formulations, creating an imperative for pharmaceutical manufacturing facilities to implement highly sensitive, robust, and reproducible stereoselective testing methodologies that verify chiral purity in bulk batches and parenteral formulations.

Conventional analytical techniques developed for monitoring bupivacaine and ropivacaine enantiomers have relied on normal-phase liquid chromatography, polar organic chromatography, micellar electrokinetic chromatography, capillary electrophoresis, or reversed-phase systems. However, these traditional modes frequently introduce significant practical and environmental drawbacks, including extended analysis times exceeding fifteen to thirty minutes, substantial consumption of toxic or volatile solvents such as n-hexane and dichloromethane, and reliance on expensive, fragile protein-based stationary phases like alpha-1-acid glycoprotein. Furthermore, polar organic approaches depend heavily on high-footprint acetonitrile, whereas standard reversed-phase modes often demand complex, corrosive salt buffers or acidic and basic additives that accelerate column degradation and preclude direct mass spectrometry coupling.

To overcome these collective analytical liabilities, the researchers turned to hydro-organic mobile phases applied across a polysaccharide-based Chiralpak AD column packed with amylose tris(3,5-dimethylphenylcarbamate) on a ten-micrometer spherical silica support measuring 250 millimeters by 4.6 millimeters. Operating the column at 25 degrees Celsius on a Waters Alliance 2695 separation module equipped with a quaternary pump and a Waters 2996 photodiode array detector, the team discovered that an isocratic eluent comprising isopropanol and water in an 85:15 volume-to-volume ratio yielded complete baseline separation of each enantiomeric pair. Delivering this eluent at a flow rate of 0.5 milliliters per minute with ultraviolet detection set at 220 nanometers allowed the separation of levobupivacaine and S(-)-ropivacaine from their corresponding R-enantiomers within an eight-minute window, with an overall run time of ten minutes.

The study demonstrated that water plays an indispensable mechanistic role when functioning as the polar modifier in the mobile phase. During preliminary scouting trials, incorporating methanol or ethanol at five percent into isopropanol generated insufficient resolution or completely failed to resolve the stereoisomers, whereas water promptly initiated enantiomeric separation. Thermodynamic and chromatographic assessments indicated that water molecules preferentially adsorb onto the polar amylose carbamate surface, establishing an organized hydration layer that modifies local polarity and hydrogen-bonding opportunities. This water-rich microenvironment facilitates preferential, strong directional hydrogen bonding between the carbamate functional groups of the stationary selector and the amide groups of the S-enantiomers, resulting in longer retention factors of 1.27 for levobupivacaine and 1.25 for S-ropivacaine and producing resolution values greater than 1.5.

Conversely, introducing ionic additives produced disastrous effects on chromatographic performance. When researchers evaluated the addition of diethylamine, trifluoroacetic acid, or their equimolar combination at concentrations ranging between 0.1 percent and 0.5 percent volume-to-volume, the stereoselective separation collapsed entirely, dropping resolution to zero. The researchers deduced that these low-molecular-weight ionic modifiers directly compete with the amino amide drug molecules for critical carbamate hydrogen-bonding sites and dismantle the structured water-enriched solvation layer. Similarly, investigating column temperatures from 25 to 45 degrees Celsius revealed an inverse relationship with separation efficiency; elevated thermal energy reduced enantioselectivity, leading the team to fix the operating temperature at 25 degrees Celsius to safeguard optimal baseline resolution.

Thermodynamic investigations through Van’t Hoff modeling across the 25 to 45 degrees Celsius range shed light on the molecular recognition driving the separation. Linear plots of natural logarithm capacity factors and separation factors against reciprocal temperature yielded high correlation coefficients exceeding 0.95, establishing an unchanging separation mechanism. Standard enthalpy changes were negative for both enantiomers, demonstrating that analyte adsorption is fundamentally exothermic, while negative entropy changes reflected increased spatial order upon diastereomeric complex formation. Because differential enthalpy changes were negative and noticeably larger than entropy losses—registering at minus 1.472 kilocalories per mole for bupivacaine and minus 1.388 kilocalories per mole for ropivacaine—the separation was confirmed to be enthalpy-driven, aligning with a three-point model governed by pi-pi interactions between aromatic rings, hydrogen bonding, and steric entrapment of alkyl side chains in the amylose helical cavities.

Validation of the hydro-organic protocol followed the rigorous criteria outlined in the International Council for Harmonisation ICH Q2(R2) guidelines. High-range calibration demonstrated exceptional linearity with coefficients of determination exceeding 0.999 over 20 to 200 micrograms per milliliter for the active S-enantiomers, while low-range calibrations spanning 2 to 20 micrograms per milliliter reliably quantified the R-configured impurities. Method precision yielded relative standard deviations below 1.36 percent for both intra-day repeatability and intermediate precision across nine separate determinations at three concentration levels. Mean analytical recoveries from spiked matrices fell within 99.4 to 100.7 percent, confirming accurate quantification without procedural bias.

Sensitivity benchmarks fully met commercial and pharmacopoeial requirements. The method produced limits of detection below 0.7 micrograms per milliliter and limits of quantitation below 2.1 micrograms per milliliter for the chiral impurities, with experimental verification confirming signal-to-noise ratios greater than ten and repeatability relative standard deviations under five percent at the quantitation threshold. Specificity was established through photodiode array spectral examinations across 200 to 400 nanometers, where peak purity angles remained consistently smaller than their corresponding purity thresholds in both resolution standards and formulated matrices. Deliberate variations in flow rate, mobile phase composition, column temperature, detection wavelength, and column manufacturing lots produced no loss in baseline resolution, confirming system robustness.

The analytical procedure proved equally effective when challenged with commercial products and representative formulation matrices. Because marketed Chirocaine and Naropin formulations are preservative-free parenteral solutions containing sodium chloride adjusted to pH 5.0, the authors evaluated simulated placebo blanks alongside authentic Marcaine injections and racemic bupivacaine bulk material. Analysis of Marcaine injections and bupivacaine drug substance successfully quantified levobupivacaine at 49.80 percent and 50.0 percent respectively, matching theoretical racemic proportions without matrix interference. When benchmarked against the official United States Pharmacopeia titrimetric assay for ropivacaine hydrochloride drug substance, statistical comparison showed no significant divergence in active content, while the chromatographic method provided the distinct operational advantage of measuring enantiomeric purity simultaneously.

The study also included a comprehensive green analytical chemistry evaluation comparing the hydro-organic protocol against published chiral liquid chromatography techniques. Utilizing four recognized benchmarking frameworks—the National Environmental Methods Index, the Analytical Eco-Scale, the Green Analytical Procedure Index, and the Analytical GREEnness calculator—the method demonstrated superior sustainability credentials. Achieving an Analytical Eco-Scale score of 92 out of 100 and an AGREE score of 0.70, the procedure outranked traditional normal-phase and reversed-phase workflows, driven by the avoidance of toxic chlorinated solvents, moderate flow rates, reduced run durations, and minimal liquid waste generation.

In their final appraisal, the authors noted that this hydro-organic chromatography framework delivers a practical, rapid, and sustainable tool capable of streamlining routine quality control in pharmaceutical laboratories. While the validation relied on formulation placebos and commercial Marcaine injections rather than finished commercial ampoules of Chirocaine and Naropin, the recovery and specificity data confirm readiness for commercial batch release. Moreover, because the isopropanol-water mobile phase is completely volatile and free of non-volatile salts, the separation mechanism offers immediate adaptability to liquid chromatography-mass spectrometry platforms and potential transfer to ultra-high-performance liquid chromatography systems for even shorter cycle times.

Subject of Research: Green chiral HPLC determination of levobupivacaine and ropivacaine enantiomers

Article Title: Green chiral HPLC method on a polysaccharide column under hydro-organic conditions for the determination of Levobupivacaine, Ropivacaine, and their enantiomeric impurities

Article References: Sedki, N. G., Fayed, A. S., Salama, N. N., & Hegazy, M. A. (2026). Green chiral HPLC method on a polysaccharide column under hydro-organic conditions for the determination of Levobupivacaine, Ropivacaine, and their enantiomeric impurities. BMC Chemistry, 20(1), Article 192. https://doi.org/10.1186/s13065-026-01870-6

Image Credits: AI Generated

DOI: 10.1186/s13065-026-01870-6

Keywords: chiral chromatography, HPLC, levobupivacaine, ropivacaine, green chemistry, analytical chemistry, pharmaceutical quality control, polysaccharide column, Green, chiral, method, polysaccharide

News Source: Bethany Barker. (November 10, 2026). Green Chiral Chromatography Method Accurately Analyzes Key Local Anesthetics. Scienmag.

Tags: analytical chemistryChiralchiral chromatographyGreenGreen chemistryHPLClevobupivacainemethodpharmaceutical quality controlpolysaccharidepolysaccharide columnropivacaine
Share12Tweet7Share2ShareShareShare1

Related Posts

Carbon Dioxide Functions as Sustainable Promoter in Metal-Catalyzed Oxidation Processes

Carbon Dioxide Functions as Sustainable Promoter in Metal-Catalyzed Oxidation Processes

November 16, 2026
Digital Metasurface System Delivers Agile Wireless Power Across Multiple Moving Targets

Digital Metasurface System Delivers Agile Wireless Power Across Multiple Moving Targets

November 16, 2026

Review Assesses Catalytic and Biological Water Treatment Methods for PFAS Degradation

November 16, 2026

X-ray Scattering Reveals Dynamic Collective Charge Excitations in Stripe-Ordered Cuprate

November 16, 2026

POPULAR NEWS

  • Longitudinal Molecular Profiling in ALK-Rearranged Lung Cancer: A Case Report

    Longitudinal Molecular Profiling in ALK-Rearranged Lung Cancer: A Case Report

    29 shares
    Share 12 Tweet 7
  • Periodontal Ligament Simulation Variations Do Not Alter Root Fracture Resistance In Vitro

    29 shares
    Share 12 Tweet 7
  • Museum Records Reveal 33,000 Non-Asilid Insect Specimens Collected by Jason Londt

    29 shares
    Share 12 Tweet 7
  • State Reconstruction Model Slashes Epidemic Infection Costs by 88 Percent

    29 shares
    Share 12 Tweet 7

About

We bring you the latest biotechnology news from best research centers and universities around the world. Check our website.

Follow us

Recent News

Low Tidal Volume Ventilation Probably Reduces Blood Loss During Liver Resection

Italian Consensus Endorses Early Vasopressin for Specific Distributive Shock Phenotypes

Advanced Lipid Bioinformatics Tools Connect Complex Lipidomics to Brain and Skin Health

Subscribe to Blog via Email

Enter your email address to subscribe to this blog and receive notifications of new posts by email.

Join 87 other subscribers
  • Contact Us

Bioengineer.org © Copyright 2023 All Rights Reserved.

Welcome Back!

Login to your account below

Forgotten Password?

Retrieve your password

Please enter your username or email address to reset your password.

Log In
No Result
View All Result
  • Homepages
    • Home Page 1
    • Home Page 2
  • News
  • National
  • Business
  • Health
  • Lifestyle
  • Science

Bioengineer.org © Copyright 2023 All Rights Reserved.