A retrospective descriptive surveillance study conducted at the Dongguan Maternal and Child Health Hospital in Dongguan, China, provides a detailed six-year account of device-associated healthcare-associated infections in a neonatal intensive care unit. The research, published in Frontiers in Public Health, analyzes data collected between 2020 and 2025 to characterize the epidemiology, device utilization, pathogen distribution, and antimicrobial resistance patterns of these infections. By applying a standardized CDC/NHSN surveillance framework, the study offers a localized view of infection risks associated with medical devices in the neonatal setting.
The study focused on three specific types of device-associated infections: ventilator-associated pneumonia, central line-associated bloodstream infection, and catheter-associated urinary tract infection. The researchers summarized annual infection rates per 1,000 device-days, calculated exact 95% confidence intervals, and analyzed device utilization ratios alongside isolate-level microbiological data.
During the six-year period, the surveillance data recorded 24 episodes of central line-associated bloodstream infection. These episodes occurred over the course of 17,033 central-line days, resulting in an infection rate of 1.41 per 1,000 line-days. The 95% confidence interval for this rate was calculated to be between 0.90 and 2.10.
Ventilator-associated pneumonia was more frequently observed than central line-associated bloodstream infection in this cohort. The study identified 46 episodes of ventilator-associated pneumonia during 21,628 ventilator-days. This translated to an infection rate of 2.13 per 1,000 ventilator-days, with a 95% confidence interval ranging from 1.56 to 2.84.
In contrast, no episodes of catheter-associated urinary tract infection were recorded during the surveillance period. The data included 2,294 urinary catheter-days, and the infection rate was zero, with a 95% confidence interval of 0.00 to 1.61 per 1,000 catheter-days.
Microbiological analysis of the isolates revealed distinct patterns among the pathogens causing these infections. For central line-associated bloodstream infections, coagulase-negative staphylococci predominated among the isolates. In the case of ventilator-associated pneumonia, gram-negative organisms accounted for 25 of the 42 recorded isolates. Staphylococcus haemolyticus was identified as the single most common isolate for ventilator-associated pneumonia.
The study also examined antimicrobial resistance classifications, noting that these varied by organism. The data supports the need for continued attention to device stewardship, microbiological surveillance, and antimicrobial stewardship in neonatal intensive care units.
This six-year surveillance study underscores the importance of ongoing monitoring of device-associated infections in neonatal care. The findings highlight the prevalence of specific pathogens and the varying rates of infection associated with different medical devices.
Subject of Research: Epidemiology and microbiology of device-associated infections in a neonatal intensive care unit
Article Title: Epidemiology, microbiological characteristics, and antimicrobial resistance of device-associated healthcare-associated infections in a neonatal intensive care unit: a six-year surveillance study
Article References: Zhang, H., Zou, M., Guo, X., Cai, J., & Liang, Z. (2026). Epidemiology, microbiological characteristics, and antimicrobial resistance of device-associated healthcare-associated infections in a neonatal intensive care unit: a six-year surveillance study. Frontiers in Public Health, 14, Article 1979471. https://doi.org/10.3389/fpubh.2026.1979471
Image Credits: AI Generated
DOI: 10.3389/fpubh.2026.1979471
Keywords: neonatal intensive care, device-associated infections, ventilator-associated pneumonia, central line-associated bloodstream infection, antimicrobial resistance, surveillance study, pathogen distribution, Epidemiology, microbiological, characteristics, antimicrobial, resistance
News Source: Kristina Jarvis. (November 8, 2026). Six-Year NICU Surveillance Tracks Device-Associated Infection Pathogens. Scienmag.